• 제목/요약/키워드: Luminance Measurement

Search Result 121, Processing Time 0.026 seconds

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Design and Data Analysis of Signal Measurement System for In-Building Propagation Characteristics (건물 내 메시지 전달특성 측정시스템 설계 및 측정결과 분석)

  • Kim, Jeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.3-6
    • /
    • 2015
  • Recently, the collection of the sensor data and its analysis become important as the smart buildings equipped with the various sensors appear as a usual scene. The interconnection through the wire cable among the sensors is indispensible because of the information collections such as the temperature, the humidity, and the luminance in the rooms and the hallways for the effective management of the in-building energies. However, these interconnections through the cabling will be very costly, time-consuming, and a difficult task since they will cause some damages to the buildings. Therefore, the interconnections through the unwired connections are required in terms of the deployment effectiveness such as time and cost In this paper, the design and the operation appropriateness are confirmed through the simulation of the signal measurement system for in-building propagation characteristics based on signature sequence and the analysis of the collected measurement data is performed thereafter.

Surface treatment of ITO with Nd:YAG laser and OLED device characteristic (Nd:YAG 레이저로 표면처리된 ITO를 전극으로 한 유기EL 소자의 특성)

  • No, I.J.;Shin, P.K.;Kim, H.K.;Kim, Y.W.;Lim, Y.C.;Park, K.S.;Chung, M.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1359-1360
    • /
    • 2006
  • lTO(Indium-Tin-Oxide) was used as anode material for OLED. Characteristics of ITO have great effect on efficiency of OLEDS(Organic light emitting diodes). ITO surface was treated by Nd:YAG laser in order to improve its chemical properties, wettability, adhesive property and to remove the surface contaminants while maintaining its original function. In this study, main purpose was to improve the efficiency of OLEDs by the ITO surface treatment: ITO surface was treated using a Nd:YAG(${\lambda}=266nm$, pulse) with a fixed power of 0.06[w] and various stage scanning velocities. Surface morphology of the ITO was investigated by AFM. Test OLEDs with surface treated ITO were fabricated by deposition of TPD (HTL), Ald3 (ETL/TML) and Al (cathode) thin films. Device performance of the OLEDs such as V-I-L was investigated using Source Measurement Unit (SMU: Keithly. Model 2400) and Luminance Measurement (TOPCON. BM-8).

  • PDF

A New Instrument for Measuring the Optical Properties of Wide-field-of-view Virtual-reality Devices

  • Ahn, Hee Kyung;Lim, Hyun Kyoon;Kang, Pilseong
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.392-399
    • /
    • 2022
  • Light-measuring devices (LMDs) are frequently used to measure luminance and color coordinates of displays. However, it is very difficult to use a conventional LMD for measuring the optical properties of virtual-reality (VR) devices with a wide field of view (FOV), because of their confined spaces where the entrance pupil of a LMD is located. In this paper, a new LMD that can measure the optical properties of wide-FOV VR devices, without physical conflict with the goggles of the VR device, is proposed. The LMD is designed to fully satisfy the requirements of IEC 63145-20-10, and a pivot-point correction method for the LMD is applied to improve its accuracy. To show the feasibility of the developed LMD and the correction method, seven VR devices with wide FOV are measured with it. From the results, all of them are successfully measured without any physical conflict, and a comparison to their nominal values shows that the FOVs have been properly measured.

Design and Data Analysis of Signal Measurement System for In-Building Propagation Characteristics based on Variable Short Signature Sequences (가변의 짧은 시그니처 시퀀스 기반 건물 내 메시지 전달특성 측정시스템 설계)

  • Kim, Jeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.10-14
    • /
    • 2015
  • Recently, the collection of the sensor data and its analysis become important as the smart buildings equipped with the various sensors appear as a usual scene. The interconnection through the wire cable among the sensors is indispensible because of the information collections such as the temperature, the humidity, and the luminance in the rooms and the hallways for the effective management of the in-building energies. However, these interconnections through the cabling will be very costly, time-consuming, and a difficult task since they will cause some damages to the buildings. Therefore, the interconnections through the unwired connections are required in terms of the deployment effectiveness such as time and cost In this paper, the design and the short sequence operation appropriateness are confirmed through the simulation of the signal measurement system for in-building propagation characteristics based on short signature sequence and the analysis of the system characteristics based on the false alarm probability is performed thereafter.

Development of Ring Light for Shadowless Shooting for Medical Purpose (의료용 무영 촬영을 위한 링라이트 개발)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.708-713
    • /
    • 2010
  • In this research a ring light was developed so that a partial shadowless shooting for the patient's affected area at the medical treatment room and surgical operation room using high luminance light emitting diode (LED) for which attention is being paid as new lighting parts for medical purpose. LED which was applied to the development used high luminance three color LED for full color for which various color materialization and the adjustment of radiation intensity are possible and we can get white light in order to emphasize the delicate expression for generic tone of shooting object, strong highlight, simple shadow and three dimensional effect at the time of close-up shadowless shooting of the affected area. And at the time of design of ring light, the characteristics of LED and the loss of light at the time of penetrating light diffusion PC were considered so that intensity of illumination for over 150 lx can be obtained. The result of measurement of the intensity of illumination of the ring light that was developed revealed that maximum intensity of illumination of 225.7 lx was obtained, while smoke index was measured to be maximum 78 Ra in the case of Red(50%) Green(100%) and Blue LED(60%). We could confirm that response speed was also very fast as 1.72 ms.

Prediction of Flicker for PDP Devices (플라즈마 디스플레이 패널의 플리커 발생에 대한 예측)

  • Jin Guang-Xu;Kang Sung-Ho;Hong Ki-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.9-18
    • /
    • 2005
  • Flicker is the 'variation in brightness or he perceived won stimulation by intermittent or temporally non uniform light'. This phenomenon is blown as the cause of eye strain and headaches. Many researchers are dedicated to reducing this phenomenon. The flicker phenomenon also exists in PDP as some other display types, and is a critical problem in 50 Hz PDP. However, it is difficult to define flicker by more than one subjective judgment. So, an objective measurement of flicker is necessary and convenient for research on displays. In this paper, a computational prediction model is proposed which is used to predict luminance flicker (not chromatic flicker) by giving a quantitative output that describes the probability of occurrence of flicker. Through this work, we expected to provide a practical tool for flicker-free design in PDP.

A Study about the Measurement and Analysis of Daylight Performance of the Changdeokgung Nakseonjae (창덕궁 낙선재의 빛환경 성능측정 및 분석에 관한 연구)

  • Kim, Yu-Sin;Lim, Ji-Sun;Jung, Yeon-Hong;Han, Wook;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.36-44
    • /
    • 2009
  • The aim of this study is to analyze the daylight performance at Changdeokgung Nakseonjae that is the representative and most well preserved Korean royal palace. As a result of measuring illuminance and luminance, direct sunlight is cut off by the eaves and reflective light from the court yard comes in the inside of the floor. As the layer of window is increased, daylight is decreased and the illuminance distribution is more stable because of decreasing of illuminance changes. Also, the lower part luminance is higher than upper part of window surface because direct sunlight is cut off by the eaves. This study would be used as preliminary data for applying characteristics of lighting environment of Korean royal palace to modem architecture.

Improvement of Reduction method for Ringing Artifacts in color moving-pictures using K-means algorithm (K-means 알고리즘을 사용한 칼라 동영상 링잉 노이즈 감쇄 방법의 개선)

  • Kim, Byung-Hyun;Jang, Jun-Young;Jang, Won-Woo;Choi, Hyun-Chul;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.576-582
    • /
    • 2011
  • In this paper, we proposed the improved Advanced Detail Enhancement algorithm that improve the blurring by the lossy compression with CODEC and reduce the ringing artifacts in restoration. The conventional algorithm needs much amount of the process by the use of RGB color space. To improve this, we only used the luminance value in YCbCr color space. We verified that the performance of the improved algorithm with Y color value, the luminance value, is equal to the conventional algorithm with RGB color value and that the operation time of the improved is shorter about 24% than the conventional through the measurement of the operation time with Kodak standard images.

Optical Properties of Color Conversion Lens for White LED Using B2O3-Bi2O3-ZnO Glass (B2O3-Bi2O3-ZnO계 유리를 이용한 백색 LED용 색변환 렌즈의 광 특성)

  • Chae, Yoo-Jin;Lee, Mi-Jai;Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Jeong, Hee-Suk;Lee, Young-Sik;Kim, Deuk-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.614-619
    • /
    • 2013
  • Recently, remote phosphor is reported for white LED enhancing of phosphor efficiency compared with conventional phosphor-based W-LED. In this study, Remote phosphor was produced by screen printing coating on glass substrate with phosphor contents rated paste and heat treatment. The paste consists of phosphor, lowest softening glass frit and organic binders. Remote phosphor can be well controlled by varying the phosphor content rated paste. After mounting remote phosphor on top of blue LED chip, CCT, CRI, and luminance efficiency were measured. The measurement results showed that CCT, CRI, and luminance efficiency were 6,645, 68, and 1,16l m/W in phosphor 80 wt.% remote phosphor sintered at $600^{\circ}C$.