• Title/Summary/Keyword: Luminance Measurement

Search Result 121, Processing Time 0.024 seconds

Development of System based on Digital Image Processing for Precision Measurement of Micro Spring (초소형 스프링 정밀 측정을 위한 디지털 영상 처리 시스템 개발)

  • 표창률;강성훈;전병희
    • Transactions of Materials Processing
    • /
    • v.11 no.7
    • /
    • pp.620-627
    • /
    • 2002
  • The purpose of this paper is the development of an automated measurement system for micro spring based on the digital image processing technique. This micro spring can be used in various engineering applications such as filament, load bearing springs, hard disk suspension and many others. Main functionality of the micro spring inspection system is to measure the representative pitch of the micro spring. The derivative operators are used for edge detection in gray level image. Measurement system developed in this paper consisted of new auto feeding mechanism to take advantage of air pressure. In the process of development of the micro spring inspection system based on the image processing and analysis, strong background technology and know-how have been accumulated to measure micro mechanical parts.

Fast Measurement of Eyebox and Field of View (FOV) of Virtual and Augmented Reality Devices Using the Ray Trajectories Extending from Positions on Virtual Image

  • Hong, Hyungki
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.336-344
    • /
    • 2020
  • Exact optical characterization of virtual and augmented reality devices using conventional luminance measuring methods is a time-consuming process. A new measurement method is proposed to estimate in a relatively short time the boundary of ray trajectories emitting from a specific position on a virtual images. It is assumed that the virtual image can be modeled to be formed in front of one's eyes and seen through some optical aperture (field stop) that limits the field of view. Circular and rectangular shaped virtual images were investigated. From the estimated ray boundary, optical characteristics, such as the viewing direction and three dimensional range inside which a eye can observe the specified positions of the virtual image, were derived. The proposed method can provide useful data for avoiding the unnecessary measurements required for the previously reported method. Therefore, this method can be complementary to the previously reported method for reducing the whole measurement time of optical characteristics.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Correction Experiment Between Luminance Measurement Value and Digital Image for Videophotometry (Videophotometry를 위한 휘도 측정치와 Digital Image사이의 보정 실험)

  • Kim, Gi-Hoon;Han, Jong-Sung;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.139-143
    • /
    • 2003
  • Digital Image와 휘도 측정치의 보정실험을 행하여 만족스러운 결과를 가져왔다. 그러나 피사체의 밝기에 비해 노출값을 너무 적게 하면 오차가 발생할 수 있다는 사실이 확인되었다. 앞으로 Videophotometry을 실현하기 위해서는 피 계측면의 분광 반사특성에 의한 계측치의 오차를 제거하기 위한 CCD 소자의 시감도 보정, 시야를 정확하게 재현하기 위한 광학적 연구, 인간의 시각 특성에 부합하는 측정 휘도의 보정 등에 대한 연구가 이루어져야 할 것이다.

  • PDF

A Study on the Characteristics of the Media Facade Buildings (미디어 파사드 건축물의 야간조명 특성분석)

  • Jung, Joo-Hee;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.45-55
    • /
    • 2010
  • Recently a number of media facade buildings making beautiful cityscape landmark has been increased in Seoul. However, indiscreet adaptation of media facade cause problems such as light pollution and poor city image. This paper was to investigate luminous characteristics of media facade building. Five representative media facade buildings in Seoul have been selected. The CS-100 and ProMetric-1400 were used to measure the luminance and color temperature of the facades. The measurement points were located at the opposite spot of the building. The results showed that maximum media facade luminance of such buildings exceed Seoul design guideline. Also, color temperature with over 5,500[K] that exceed the design guideline were mostly used in all the facades.

The Role of the Pattern Edge in Goldfish Visual Motion Detection

  • Kim, Sun-Hee;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.6
    • /
    • pp.413-417
    • /
    • 2010
  • To understand the function of edges in perception of moving objects, we defined four questions to answer. Is the focus point in visual motion detection of a moving object: (1) the body or the edge of the object, (2) the leading edge or trailing edge of the object, (3) different in scotopic, mesopic and photopic luminance levels, or (4) different for colored objects? We measured the Optomotor Response (OMR) and Edge Triggering Response (ETR) of goldfish. We used a square and sine wave patterns with black and red stripes and a square wave pattern with black and grey stripes to generate OMR's and ETR's in the goldfish. When we used black and red stripes, the black leading edges stimulated an ETR under scotopic conditions, red leading edges stimulated an ETR under photopic conditions, and both black and red leading edges stimulated an ETR under mesopic luminance levels. For black and gray stripes, only black leading edges stimulated an ETR in all three light illumination levels. We observed less OMR and ETR results using the sine wave pattern compared to using the square wave pattern. From these results, we deduced that the goldfish tend to prefer tracking the leading edge of the pattern. The goldfish can also detect the color of the moving pattern under photopic luminance conditions. We decided that ETR is an intriguing factor in OMR, and is suitable as a method of behavioral measurement in visual system research.

The Detection Distance of Colored Target using Various Automotive Headlamps

  • Kim, Jung-Yong;Lee, Ho-Sang;Min, Seung-Nam;Lee, Min-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.421-426
    • /
    • 2012
  • As headlamp technology advances, newly developed various headlamps were introduced in the market. The objective of this study is to quantitatively analyze the detection distance of the recently developed LED headlamps and existing headlamps, complying with specific technical standard. Background: The detection distance of headlamps is very important to prevent automobile accident at night time. The studies of detection distance of LED, Halogen and HID headlamp have been conducted, but no study has shown the detection distance of pedestrian target with various colors (Black, White, Blue). Method: The experiment of detection distance was conducted with 30 people, which divide into 2 groups as 15 men and 15 women. Automatic transferable target on the rail was manufactured in order to reduce the error of study's result, and ANOVA also conducted to analyze the main effect with sign color, sex and headlamp classified by detection distance. In addition, the luminance by average detection distance was measured as well. Results: The detection distance of headlamps was HID > LED > Halogen. The luminance measure of LED headlamp was lower than HID and Halogen headlamps. Conclusion: The headlamp performs a very significant role for safety at night time but it needs to be improved through assessment of visual characteristics. Also, it needs to be suggested the need of test method for dynamic detection distance concerning technical development is suggested.

Characteristics Comparison of Fluorescent Lamp with External Electrode Materials for Digital (디지털용 외부 전극층 재료를 이용한 형광램프의 특성비교)

  • Kim, Soo-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.549-554
    • /
    • 2007
  • In this paper, the luminance and resistance from different electrode materials of external electrode fluorescent lamp are measured and analyzed. New materials and process technology of external electrode are very important for the developed characteristics in lamp fabrication. This experiment, three different types for the forming of external electrode are Cu and Al taping, silver paste, Ni and Cu electrode-less plating methods. In the measurement of luminance, the results of brightness by Ni and Au plating methods for the external electrode on lamp glass are presented and also compared with the results by the methods using different electrode materials. The measured resistance values of Ni and Au plating process showed a little bit higher than that of silver paste process in spite of developed results of brightness. The Ni and Ni/Au plating processes are demonstrated best results and also showed a little bit different brightness due to different previous surface etching treatments.

Influence of Detailed Structure and Curvature of Woven Fabric on the Luminescence Effect of Wearable Optical Fiber Fabric (직물의 세부 구조 및 굴곡이 웨어러블 광섬유의 발광 효과에 미치는 영향)

  • Yang, Jin-Hee;Cho, Hyun-Seung;Kwak, Hwy-Kuen;Oh, Yun-Jung;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.55-62
    • /
    • 2018
  • The two main requirements of wearable optical fiber fabrics are that they must presuppose a high degree of flexibility and they must maintain the luminance effect in both flat and bent conformations. Therefore, woven optical fiber fabrics that satisfy the above conditions were developed by both weaving and by using computer embroidery. First, we measured the brightness of the wearable optical fiber fabric in the flat state at a total of 10 measurement points at intervals of 1 cm. Second, the wearable optical fiber fabric was placed horizontally on the forearm, where three-dimensional bending occurs, and the luminance values were recorded at the same 10 measurement points. For the woven fabric in the flat state, the maximum, minimum, average, and standard deviation luminance values were $5.23cd/m^2$, $2.74cd/m^2$, $3.56cd/m^2$, and $1.11cd/m^2$, respectively. The corresponding luminance values from the bent forearm were $7.92cd/m^2$ (maximum), $2.37cd/m^2$ (minimum), $4.42cd/m^2$ (average), and $2.16cd/m^2$ (standard deviation). In the case of the computer-embroidered fabric, the maximum, minimum, average, and standard deviation luminance values in the flat state were $7.56cd/m^2$, $3.84cd/m^2$, $5.13cd/m^2$, and $1.04cd/m^2$, respectively, and in the bent forearm state were $9.6cd/m^2$, $3.63cd/m^2$, $6.13cd/m^2$, and $2.26cd/m^2$, respectively. Therefore, the computer-embroidered fabric exhibited a higher luminous effect than the woven fabric because the detailed structure reduced light-loss due to the backside fabric. In both types of wearable optical fiber fabric the luminance at the forearm was 124% and 119%, respectively, and the light emitting effect of the optical fiber fabric was maintained even when bent by the human body. This is consistent with the principle of Huygens, which defines the wave theory of light, and also the Huygens-Fresnel-Kirchhoff principle, which states that the intensity of light increases according to the magnitude of the angle of propagation of the light wavefront (${\theta}$).

Laser Marking for Light Guide Panel using Design of Experiment and Construction of Web-based Prototyping System (실험계획법을 이용한 도광판 레이저 마킹 및 웹기반 시스템 구축)

  • Kang H.J.;Kim H.J.;Ahn S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.728-731
    • /
    • 2005
  • A light guide panel (LGP) is an element of the LCD back light unit, which is used for display devices. In this study, a laser marking process is applied to the fabrication of light guide panels as the new fabrication process. In order to obtain a light guide panel which has high luminance and uniformity, four principal parameters such as power, scanning speed, ratio of line gap, and number of line were selected as important factors. A Web-based design tool was developed to generate patterns of light guide panel, and the tool may assist the designer to develop optimized patterns. Topcon-BM7 was used for luminance measurement of each specimen 100mm$\times$100mm area. By Taguchi method optimized levels of each parameters such as 40W of power, 30mm/s of scanning speed, 100:50 ratio of pattern gap, and 90 line of pattern were found by Taguchi method.

  • PDF