• Title/Summary/Keyword: Luminance Analysis

Search Result 195, Processing Time 0.029 seconds

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Empirical Equations for the Analysis of the Time Dependence of the Luminance Properties of LCD Panels and Backlights for TV Applications

  • Ryu, Jin-Sun;Kim, Su-Jin;Park, Seung-Mi;Ko, Jea-Hyeon
    • Journal of Information Display
    • /
    • v.11 no.2
    • /
    • pp.39-44
    • /
    • 2010
  • The time dependences of the luminance properties of 55-inch CCFL and LED backlights and 32-inch FFL backlights with LCD panels were investigated during the warm-up time from the cold start. The long-term luminance maintenance curve of a standard CCFL was examined in a time window up to 5000 hours. These two time dependences are important characteristics from the viewpoint of initial picture quality and lifetime reliability, respectively. Empirical equations were suggested for the analysis of the time dependence of these luminance data. These approaches are expected to be helpful in predicting the luminance properties of backlights based on the luminance data obtained in a limited time window.

Measurement and Analysis of Adaptation Luminance in the Threshold Zone of the Road Tunnel (도로터널의 경계부 순응휘도 측정 및 분석)

  • Han, Jong-Sung;Lee, Min-Wook;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • As the standard lighting required in the threshold zone of a road tunnel is determined by the enough contrast. Lighting design, therefore, must be determined by the calculation method of threshold luminance based on the adaptation luminance of the driver approaching the tunnel. The veiling luminance and the luminance in the access zone were measured at different time and in different weather using the veiling luminance method, a kind of perceived contrast methods, and the L20 method when the range of vision was 20 degrees. On the basis of the measured data each threshold luminance was calculated and its results were analyzed.

A Study of HDR Software Reliability for the Luminance Map Creation (휘도맵의 작성을 위한 HDRI 생성 도구의 신뢰도에 관한 연구)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.3
    • /
    • pp.81-89
    • /
    • 2012
  • Luminance is the most important quantity in lighting design and illuminating engineering. There are three methods for measuring luminance; using a conventional luminance meter, through the illuminance measurement and subsequent calculations and using digital imaging photometer. Recently, HDRI(High Dynamic Range Imaging) technique introduces a new method of capturing luminance values in a lighting environment. The radiance maps from HDRI are commonly used as visual environment maps for lighting analysis applications. For the HDRI, HDR software is needed to create HDR image. Currently, there is number of HDR software available. The purpose of this paper is to investigate whether a luminance map can be accurately captured by the various types of HDR software which include HDR Shop and Photoshop. To accomplish this goal a set of experiments was conducted. In order to assess the luminance values of the HDR image from HDR software, the values had to be compared to the ones obtained with conventional methods of luminance measurement.

An EV Range in HDRI Acquisition as a Luminance Map Creation (휘도맵의 작성을 위한 HDRI 획득에 있어서 EV의 범위)

  • Hong, Sung-De
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.5-12
    • /
    • 2010
  • The purpose of this study is to present the EV range in HDRI acquisition process to create luminance map. The proposed method in this study is to capture the scene at EV ${\pm}0$ that is the longest exposure points and reference point in the scene. With this reference point, sets of 25 LDRI test case were taken manually at ${\pm}2$ EV using the aperture-priority manual mode. The 25 HDRIs were created using Adobe Photoshop. The HDRIs were then imported Radiance lighting simulation program to be analyzed into falsecolor. The analysis results of the 25 HDRIs test case are 50[%] of the all tested case have a margin of error of 10[%]. In case of f/5.6, the luminance map generated with HDRI were similar to the spot luminance meter. As a result, the EV range to reduce error of luminance map generated with HDRI is EV $+2{\sim}{\pm}0{\sim}-10$.

A Study on the Image-Based Luminance Measurement System Using the Measuring Position (측정 위치를 고려한 영상기반 휘도측정시스템에 관한 연구)

  • Sun, Eun-Hey;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.4
    • /
    • pp.424-429
    • /
    • 2014
  • In this paper, an image-based luminance measurement system(LMS) is proposed to measure the luminance of outdoor signboards. We design the LMS that can improve disadvantages of efficiency of the point-luminance meter and portability of face-luminance meter using the image of DSLR camera and print out the luminance value by using the proposed luminance analysis algorithm in real time. Outdoor signboards have various size and shape, and are also installed on the various place. Luminance of the signboard is influenced by measurement location, angle, color, etc. Therefore, we measure the change of luminance value in accordance with measurement location for accurate luminance measurement and then consider the luminance value according to the measurement distance. We obtain a numerical relation between luminance value and measurement location. The proposed LMS is verified through comparative experiment with point-luminance meter.

CCFL Backlight characterization using luminance meter and image analysis.

  • Gibour, Veronique;Boher, Pierre;Leroux, Thierry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.791-794
    • /
    • 2004
  • In this article, we present a method to measure precisely the performances of direct-lit CCFL backlights using a luminance meter and dedicated image analysis software. The array of CCFL tubes alone can be measured directly and the luminance of each tube can be extracted along its main dimension. So, comparison of the different tubes on the same backlight can be made easily and the performances in terms of backlight uniformity improved. The influence of the diffuser sheet can be probed in the same way and the homogeneity of the entire surface of the backlight can be automatically extracted and quantified.

  • PDF

A Study on luminance Measurement Method of Lightscape using DSLR (DSLR를 이용한 야간경관 휘도 측정 기법에 관한 연구)

  • Lee, Wan-Soo;Chung, Kang-Wha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.10-17
    • /
    • 2009
  • A lightscape is displayed by lots of luminance containing the wide range of lighting. The measurement of the luminance is limited because the brightness distribution was measured from a point in the existing methods. We used DSLR cameras to get information of the luminance efficiently and conveniently. The application of DSLR camera which easily provides images is widely used nowadays. We suggested the analysis of the luminance and measurement method of the scene from DSLR images using luminance distribution measurement technique.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.