• Title/Summary/Keyword: Lumbar range of motion

Search Result 123, Processing Time 0.031 seconds

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Intensive Korean Medicine Treatments for Low Back Pain and Decreased Living Function due to Herniation Intervertebral Discs in the Lumbar Spine: A Case Study (요추 추간판 탈출증으로 인한 요통 및 생활기능저하에 대한 한방 집중치료 치험 1례)

  • Choi, Ki-won;Kim, Tae-ju;Park, Han-bin;Yoo, Dong-hui;Kim, Ho;Lee, Sang-gun;Jo, Hyun-woo;Choi, Jae-yong
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.2
    • /
    • pp.283-292
    • /
    • 2020
  • Background: This case study suggests the potential use of Korean medicine treatments as a conservative management for low back pain and decreased living function due to herniation of intervertebral discs in the lumbar spine. Case Summary: The patient suffered low back pain and decreased living function due to herniation of intervertebral discs of the lumbar spine. Korean medicine treatments, including herbal medicine, acupuncture performed on BL23, BL40, SP6, and GB39, and pharmacupuncture containing Sinbaro, were applied for eight days. The numeric rating scale (NRS) results for low back pain decreased from 6 to 2 and the Oswestry Disability Index (ODI) low back pain scores decreased from 75.56 to 31.11. Walking time also increased from less than one minute to 20 minutes, with an increase in range of motion (ROM) from "Uncheckable" to about normal motion range. Conclusion: Korean medicine treatment can be considered to be an effective conservative management option for pain and decreased living function in patients with herniation of intervertebral discs in the lumbar spine.

Effects of Axillary Crutch Length on EMG Activity of the Trunk Muscles and Range of Motion of the Lumbar Spine, Pelvis, and Hip Joint in Healthy Men

  • Kang, Min-Hyeok;Jang, Jun-Hyeok;Kim, Tae-Hoon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • This study investigated the effects of axillary crutch length on trunk muscle activity and lumbo-pelvic-hip complex movements during crutch gait. Eleven healthy men participated in this study. The participants performed a three-point gait with optimal, shorter, and longer crutch lengths. Weight-bearing (WB) side was determined as the dominant leg side. The electromyography (EMG) activity of the bilateral rectus abdominis (RA) and erector spinae (ES) muscles and lumbo-pelvic-hip complex movements were monitored using a three-dimensional motion system with wireless surface EMG. Differences in the EMG activity of RA and ES muscles and range of motion (ROM) of lumbar spine, pelvis, and hip among conditions were analyzed using one-way repeated-measures analysis of variance, and a Bonferroni correction was conducted. There was less RA muscle activity on the WB side under the optimal crutch length condition compared with shorter and longer crutch length conditions (p<.05). The EMG activity of the RA muscle on the non-WB side and ES muscle on the WB side were significantly decreased under the optimal crutch length condition compared with shorter crutch length condition (p<.05). No significant differences in the EMG activity of the ES muscle on the non-WB side and ROM of lumbo-pelvic-hip complex were found among conditions (p>.05). These findings indicate that the optimal crutch length improves the trunk muscle efficiency during crutch gait.

The Effect of Acupotomy on Lumbar Herniated Intervertebral Disc: Report of a Case Series (요추 추간판 탈출증 환자에 대한 도침을 포함한 한방 복합치료 효과: 연속증례보고)

  • Kim, Hye Su;Kim, So Yun;Kim, Hyun Ji;Kim, Eun Seok;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.185-195
    • /
    • 2015
  • Objectives : This is a case series reporting of the improvement in patients with a lumbar herniated intervertebral disc by means of acupotomy combined with oriental medicine. Methods : We treated seven patients with a lumbar herniated intervertebral disc with acupotomy combined with oriental medical treatment. We checked the numeric rating scale(NRS), oswestry low back pain disability index(ODI) and range of motion(ROM). Results : NRS and ODI decreased, and ROM improved in all cases. Conclusions : This study shows acupotomy has a meaningful effect when applied on a lumbar herniated intervertebral disc.

Biomechanical Study of Lumbar Spinal Arthroplasty with a Semi-Constrained Artificial Disc (Activ L) in the Human Cadaveric Spine

  • Ha, Sung-Kon;Kim, Se-Hoon;Kim, Daniel H.;Park, Jung-Yul;Lim, Dong-Jun;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.169-175
    • /
    • 2009
  • Objective : The goal of this study was to evaluate the biomechanical features of human cadaveric spines implanted with the Activ L prosthesis. Methods : Five cadaveric human lumbosacral spines (L2-S2) were tested for different motion modes, i.e. extension and flexion, right and left lateral bending and rotation. Baseline measurements of the range of motion (ROM), disc pressure (DP), and facet strain (FS) were performed in six modes of motion by applying loads up to 8 Nm, with a loading rate of 0.3 Nm/second. A constant 400 N axial follower preload was applied throughout the loading. After the Activ L was implanted at the L4-L5 disc space, measurements were repeated in the same manner. Results : The Activ L arthroplasty showed statistically significant decrease of ROM during rotation, increase of ROM during flexion and lateral bending at the operative segment and increase of ROM at the inferior segment during flexion. The DP of the superior disc of the operative site was comparable to those of intact spine and the DP of the inferior disc decreased in all motion modes, but these were not statistically significant. For FS, statistically significant decrease was detected at the operative facet during flexion and at the inferior facet during rotation. Conclusion : In vitro physiologic preload setting, the Activ L arthroplasty showed less restoration of ROM at the operative and adjacent levels as compared with intact spine. However, results of this study revealed that there are several possible theoretical useful results to reduce the incidence of adjacent segment disease.

Development of Quantitative Diagnostic Technique for Low-Back Pain Patients via Three Dimensional Dynamic Motion Analysis (3차원 동작분석에 의한 요통환자의 정량적 진단기법 개발에 관한 연구)

  • Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.11-23
    • /
    • 1998
  • Dynamic motion difference between normal subjects and low-back pain (LBP) patients has been investigated in terms of kinematic variables such as range of motion, velocity and acceleration of the back and hip. Ten healthy subjects and ten LBP patients were recruited in this study. Electro-goniometer such as Lumbar Motion Monitor and Hip Monitor have been used for quantitative measurement of the trunk motion during repetitive flexion and extension for ten seconds. Results indicated that the velocity and acceleration of the back and hip were important parameters to quantitatively identify LBP patients. The consistency of cyclic trunk motion and the relationship between the back and hip were measured in terms of Variance Ratio and Phase Angle in order to accurately assess the motion characteristics of LBP patients. In particular, the hip motion has been proven to be a very important factor in describing the kinematics of damaged lower back. The functional evaluation technique suggested in this study will be a tool to assist physicians for an accurate diagnosis and timely rehabilitation along with current image diagnosis techniques.

  • PDF

Cervical and Lumbar Herniated Nucleus Pulposus Resorption after Acupotomy with Integrative Korean Medicine Treatment: A Case Series of Two Patients

  • Lee, Ye Ji;Kim, Jae Ik;Kim, Hyo Bin;Jeon, Ju Hyun;Kim, Eunseok;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.36 no.2
    • /
    • pp.107-112
    • /
    • 2019
  • The aim of this study was to report on the resorption of herniated nucleus pulposus following acupotomy treatment. Two patients were treated with acupotomy which included integrative Korean Medicine treatment, for either cervical, or lumbar herniated nucleus pulposus. Magnetic Resonance Imaging was used to produce images before and after (several months) treatment. The Numerical Rating Scale scores and Range of Motion were used to assess the patients at admission and discharge. In both cases, substantial resorption of the respective herniated disc was observed in the magnetic resonance images, with a decrease in the Numerical Rating Scale score. Range of Motion improved in 1 case. This study shows that acupotomy treatment may be a clinically effective treatment for herniated nucleus pulposus resorption and pain relief.

Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method

  • Choi, Jisoo;Kim, Sohee;Shin, Dong-Ah
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.91-97
    • /
    • 2016
  • Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.

The Effect of Acupotomy on Lumbar and Cervical Spine Combined with Oriental Medical Treatment: Report of Five Cases (척추질환에 도침치료를 포함한 한방복합치료 치험 5례)

  • Kim, So Yun;Kim, Hyun Ji;Ji, Young Seung;Lee, Seung Min;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.183-193
    • /
    • 2014
  • Objectives : The purpose of this study is to report the improvement in patients with lumbar, cervical or radiating pain to the extremity by means of acupotomy. Methods : We treated 5 patients who have a disease related with lumbar or cervical spine with acupotomy combined with oriental medical treatment. We checked numeric rating scale(NRS), oswestry low back pain disability index(ODI) or neck disability index(NDI), and range of motion(ROM). Results : NRS and ODI/NDI were decreased, and ROM improved at all cases. Conclusions : This study shows acupotomy has a meaningful effect when applied on lumbar and cervical spine.

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.