• Title/Summary/Keyword: Lowest Resolution

Search Result 120, Processing Time 0.029 seconds

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Multispectral Image Compression Using Classification in Wavelet Domain and Classified Inter-channel Prediction and Selective Vector Quantization in Wavelet Domain (웨이브릿 영역에서의 영역분류와 대역간 예측 및 선택적 벡터 양자화를 이용한 다분광 화상데이타의 압축)

  • 석정엽;반성원;김병주;박경남;김영춘;이건일
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.31-34
    • /
    • 2000
  • In this paper, we proposed multispectral image compression method using CIP (classified inter-channel prediction) and SVQ (selective vector quantization) in wavelet domain. First, multispectral image is wavelet transformed and classified into one of three classes considering reflection characteristics of the subband with the lowest resolution. Then, for a reference channel which has the highest correlation with other channels, the variable VQ is performed in the classified intra-channel to remove spatial redundancy. For other channels, the CIP is performed to remove spectral redundancy. Finally, the prediction error is reduced by performing SVQ. Experiments are carried out on a multispectral image. The results show that the proposed method reduce the bit rate at higher reconstructed image quality and improve the compression efficiency compared to conventional method.

  • PDF

PCR-based genotyping of Korean population for forensic applications

  • Ryu, Jae-Song;Gu, Yun-Mo;So, Jae-Seong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.592-595
    • /
    • 2000
  • In human chromosome, a short sequence of DNA has been repeated a number of times. These repeats are called variable number of tandem repeat(VNTR) or short tandem repeat(STR) which has short repeat core. VNTR and STR are used in the field of forensic science, evolution, and anthropology. In this work, we examined allele frequencies of 3 VNTR(YNZ22, NeuR, D21S11) and one STR(Humth01) in a Korean population sample by polymerase chain reaction(PCR) followed by high-resolution polyacrylamide gelelectrophoresis(PAGE) with silver staining. Subsequently, the polymorphism information content(PIC) was calculated : the highest PIC was observed for the NeuR locus(0.95680) and lowest for the Humth01 locus(0.75809).

  • PDF

A Study on the Thermal and Electrical Characteristics with Manufacture of the Heating Element by Using Carbon with Bar Type (봉상 카본 발열체의 제조와 열 및 전기적 특성에 관한 연구)

  • 배강열;이광성;정한식;정희택;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.430-437
    • /
    • 2004
  • This paper is intended as an investigation of study on the thermal and electrical characteristics of the carbon heating element. In this experimentation, the electric material used is the crystalline graphite a kind of natural graphite. The bentonite is used to solidify the heating element and the vacuum furnace is used for sintering it. It is noted that the natural drying time should be at least 58 hours. The plating of the electric pole with the electroless nickel showed the lowest contact resistance among others. The resistance shows linear variation with regard to length. For the insulation and resolution, the glaze coating is best with 80% of water content. The temperature rising characteristic of the heating element is better than sheath heater saving 43% of rising time. The correlation equation for temperature was obtained with the electric power.

Internet-Based Measuring/Monitoring System that Measures Drifted Snow Using Visual Image

  • Ko, Deok-Hyeon;Kim, Moo-Seong;Lee, Soon-Geul;Kim, Jin-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.173.2-173
    • /
    • 2001
  • In this paper, an Internet-based monitoring system is studied which analyzes visual image of drifted snow and measures the amount of snowing. The system is composed with reference ruler where LED's are attached, a camera, and PC with a controller. The length of the ruler is 1.5m and the interval of the LED's is 1cm. The controller synchronizes the on-off control of each LED with the image frame of the camera. When the snow is accumulated along the ruler, the corresponding LED is blocked and the lowest position of the lighted LED is estimated with this captured image of the camera. Because of week intensity of LED light and light rays of outdoors, it is hard to discriminate which LED is blocked due to snow. Image processing method is used to obtain proper resolution and good accuracy. This system ...

  • PDF

Technical Advances, Image Quality and Quality Control Regulations in Mammography

  • Ng, Kwan-Hoong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.38-41
    • /
    • 2002
  • Mammography is considered the single most important diagnostic tool in the early detection of breast cancer. Today's dedicated mammographic equipment, specially designed x-ray screen/film combinations, coupled with controlled film processing, produces excellent image quality and can detect very low contrast small lesions. In mammography, it is most important to produce consistent high-contrast, high-resolution images at the lowest radiation dose consistent with high image quality. Some of the major technical development milestones that have let to today's high quality in mammographic imaging are reviewed. Both the American College of Radiology Mammography Accreditation Program and the Mammography Quality Standards Act have significant impact on the improvement of the technical quality of mammographic images in the United States and worldwide. A most recent development in digital mammography has opened up avenues for improving diagnosis.

  • PDF

PCR Analysis of Four Length-Polmorphic Loci in Korea Population for Genotyping

  • Ryu, Jae-Song;Koo, Yoon-Mo;So, Jae-Seong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.3
    • /
    • pp.169-173
    • /
    • 2000
  • On human chromoscomes, a short sequence of DNA is known to repeat a number of times. These are called variable number of tandem repeat (VNTR) or short tandem respeat (STR) which has a short core. VNTR and STR are used in the filed of forensic science, evolution, and anthropology. In this work, we examined allele frequencies of one VNTR (YNZ22) and three STRs (NeuR, D21S11, Humth01) in a korean population sample by polymerase chain reaction (RCP) followed by high-resolution polyacrylamide gel electro-phoresis (PAGE) with silver stain. Subsequently, the polymorphism information content (PIC) was calculated : the hifhest PIC was observed in the NeuR locus (0.95680) and lowest in the Humth01 locus (0.75809).

  • PDF

Performance Evaluation of Different Factors According to ROI Coding Methods in JPEG2000

  • Kim, Ho-Yong;Shim, Jong-Chae;Seo, Yeong-Geon
    • Journal of Digital Contents Society
    • /
    • v.7 no.3
    • /
    • pp.183-191
    • /
    • 2006
  • Currently, the preferred processing of a user-centered ROI(Region-of-Interest) or a specific region of image to transmission and decompression of a full image is needed in different applications, specifically mobile applications. Here, we have to study how different factors affect ROI coding methods. Therefore, an application can select an ROI coding method and several parameters suitable for the environments. The ROI coding methods used in the study are Maxshift and Implicit and the parameters are tile size, image size, code block size, ROI importance and the number of lowest resolution levels. This study shows the experimental results between the different parameters and the two ROI coding methods.

  • PDF

Surface Reflectance Retrieval from Satellite Observation (OMI) over East Asia Using Minimum Reflectance Method (위성관측 오존계에서 최소 반사도법을 이용하여 동아시아 지역의 지면반사도 산출)

  • Shin, Hee-Woo;Yoo, Jung-Moon;Lee, Kwon-Ho
    • Journal of the Korean earth science society
    • /
    • v.40 no.3
    • /
    • pp.212-226
    • /
    • 2019
  • This study derived spectral Lambertian Equivalent Reflectance (LER) over East Asia from the observations of Ozone Monitoring Instrument (OMI) onboard polar-orbit satellite Aura. The climatological (October 2004-September 2007) LER values were compared with the surface reflectance products of OMI or MODerate resolution Imaging Spectroradiometer (MODIS) in terms of the atmosphere-environment variables as follows: wavelength (UV, visible), surface properties (land, ocean), and cloud filtering. Four kinds of LER outputs in the UV and visible region (328-500 nm) were retrieved based on the averages of lowest (1, 5, and 10%) surface reflectance values as well as the minimum reflectance. The average of the lowest 10% among them was in best agreement with the OMI product: correlation coefficient (0.88), RMSE (1.0%) and mean bias (-0.3%). The 10% average and OMI LER values over ocean were 2% larger in UV than in visible, while the values over land were 1% smaller. The LER variability on the wavelength and surface property was highest (~3%) in the condition of both land and visible, particularly in the ice-cap and desert regions. The minimum reflectance values over the oceanic and inland sample areas overestimated the MODIS product by 1.4%. This high-resolution MODIS observations were effective in removing cloud contamination. The relative errors of the 10% average to MODIS were smaller (-0.6%) over ocean but larger (1.5%) over land than those of the OMI product to MODIS. The reduced relative error in the OMI product over land may result from additional cloud filtering using the Landsat data. This study will be useful when retrieveing the surface reflectance from geostationary-orbit environmental satellite (e.g., Geostationary Environment Monitoring Spectrometer; GEMS).

Deposition flux of dioxin-like polychlorinated biphenyls(DLPCBs) in urban environment of Busan (도심 지역의 다이옥신류 폴리염화비페닐류의 침적 플럭스)

  • Mun, Hyo-Bang;Lee, Su-Jeong;Choe, Hui-Gu;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.13 no.5
    • /
    • pp.469-478
    • /
    • 2004
  • Atmospheric bulk (wet and dry) samples were monthly collected in an urban environment (Daeyeon-dong) of Busan over a year, to assess the deposition flux and seasonality of dioxin-like polychlorinated biphenyls (DLPCBs) using stainless steel pots. Deposition fluxes of DLPCBs in bulk samples were determined using high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS). Particle deposition fluxes in the urban environment varied from 23 to 98 $mg^2$/year (mean 41 $gm^2$/year). DLPCB deposition fluxes in atmospheric bulk samples ranged from 0.09 to 0.77 ng-$TEQ/m^2$/year (mean 0.35 ng-$TEQ/m^2$/year). Seasonal atmospheric deposition fluxes of DLPCBs were high in winter and low in summer. Atmospheric deposition fluxes of particles and DLPCBs in this study were comparable to or slightly lower values than those of different locations in the world. Monthly DLPCB profiles in deposition bulk samples were similar over a year. Non-ortho PCBs were higher contributions to the total DLPCBs fluxes than mono-ortho PCBs. In particular, PCB 126 had the highest concentrartion (>75%) in all deposition samples, followed by PCB 169 and PCB 156. A highly positive correlation was found among the deposition fluxes of DLPCB species, suggesting the possibility of that the DLPCB contamination originated from one source. The deposition fluxes of DLPCBs were not significantly correlated with temperature and the amount of precipitation even though the summer season with the highest temperature and the largest amount of precipitation showed the lowest DLPCB deposition flux.