• Title/Summary/Keyword: Lower-plenum arrested vessel attack

Search Result 3, Processing Time 0.023 seconds

Development of Ultrasonic Magnetostrictive Sensors System to Measure in Very High Temperatures (초고온 온도 측정을 위한 초음파 자왜 센서 시스템 개발)

  • 구길모;김상백;박치승;최종호;고덕영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.66-74
    • /
    • 2001
  • The temperature measurement of yen high temperature core melt is of importance in LAVA (Lower-plenum Arrested Vessel Attack) experiment in which gap formation between core melt and the reactor lower head, and the effect of the gap on thermal behavior are to be measured. The delay time of ultrasonic wavelets due to high temperature is suggested. As a first stage, a molten material temperature was measured up to 2300℃. Also, the optimization design of the ultrasonic temperature sensor with persistence at the high temperature was suggested in this paper. And the utilization of the theory suggested in the reference〔1〕and the efficiency of the developed system are certified by performing experiments. This sensor welded magnetostrictive element and tungsten element will be able to measure a temperature range of 3000℃ hereafter.

  • PDF

Multi-layered Gap Measurement on In-Vessel Cerium Retention Using Ultrasonic Wave Reflective Pattern Analysis and Frequency Diversity Signal Processing (초음파 반사 패턴과 주파수 대역 분할 신호처리를 이용한 다층구조인 노내 간극 측정)

  • Koo, Kil-Mo;Sim, Cheul-Mu;Kim, Jong-Hwan;Kim, Sang-Baik;Kim, Hee-Dong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • A gap between a $Al_2O_3/Fe$ thermite and lower head vessel is formed in the lower-plenum arrested vessel attack(LAVA) experiment which is the 1st phase study of simulation of naturally arrested vessel attack in vessel(SONATA-IV). The gap measurement using a conventional ultrasonic method would be lack of a reliability due to the structure complexity and the metallurgical grain size change of the lower head HAZ occurred by a thermite $Al_2O_3/Fe$ melt or a $Al_2O_3$ melt at $2300^{\circ}C$. The grain echoes having false signals and lower S/N ratio signals are detected due to a multiple scattering, a mode conversion and an attenuation of a ultrasonic resulted from at the interface of increased grain size zone. In this test, the signals pattern was classified to understand the behavior of the ultrasonic in a multi-layer specimen of solid-liquid-solid of assuming that the thermite and the lower head vessel is immersed. The polarity threshold algorithm of frequency diversity gives us the enhancement about 6dB of the ratio S/N.

  • PDF

용융물 냉각 및 간극 형성 실험(LAVA)연구

  • 강경호;김종환;조영로;김상백;김희동
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.669-674
    • /
    • 1997
  • LAVA(Lower-plenum Arrested Vessel Attack) 실험은 중대사고시 고온의 노심 용융물이 냉각수가 존재하는 원자로 용기 하부 반구내로 재배치되는 경우 노심 용융물과 하부반구의 열적 거동 모사와 노심용융물과 하부 반구 사이의 구조 분석 및 고화 후의 용융물형상에 대한 관측을 통하여 노심용융물의 자연 냉각 현상을 규명하고자 하는 실험 연구이다. 원자로 용기 하부 반구를 1/8로 선형 축소한 반구형 반응 용기 내부로 $Al_2$O$_3$/Fe Thermite 용융물을 주입하여 용융물과 하부 반구 사이의 구조 및 하부 반구의 열적 거동을 분석하는 실험을 2회 수행하였다. 각각 20, 40kg의 $Al_2$O$_3$/Fe Thermite 용융물을 주입시 킨 LAVA_PRE, LAVA-1 실험 결과 용융물 주입에 따른 하부 반구의 파손은 발생하지 않았으며, 유사한 실험조건에서 수행된 일본 ALPHA실험에 비해서는 하부 반구의 최대 온도가 500 K 이상 높게 측정되었고 냉각율 또한 현저히 낮게 나타났다. 이는 $Al_2$O$_3$/Fe Thermit 용융물중 과열상태의 Fe성분이 하부 반구와 용접되었기 때문으로 판단되며 보다 정확한 하부 반구의 열적거동을 모사하기 위하여 반구 시편에 대한 재료, 조직 검사를 수행하고 있다. 추후의 실험에서는 하부 반구 내외부의 압력 부하에 따른 반응 양상 및 Fe 용융물(금속용융물) 성분을 제거하고 순수한 $Al_2$O$_3$용융물(산화용융물) 만을 주입하여 용융물 성분에 따른 하부 반구의 열적거동을 분선 할 예정이다.

  • PDF