• 제목/요약/키워드: Lower-floor

Search Result 652, Processing Time 0.022 seconds

AGV-induced floor micro-vibration assessment in LCD factories by using a regressional modified Kanai-Tajimi moving force model

  • Lee, C.L.;Su, R.K.L.;Wang, Y.P.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.4
    • /
    • pp.543-568
    • /
    • 2013
  • This study explores the floor micro-vibrations induced by the automated guided vehicles (AGVs) in liquid-crystal-display (LCD) factories. The relationships between moving loads and both the vehicle weights and speeds were constructed by a modified Kanai-Tajimi (MKT) power spectral density (PSD) function whose best-fitting parameters were obtained through a regression analysis by using experimental acceleration responses of a small-scale three-span continuous beam model obtained in the laboratory. The AGV induced floor micro-vibrations under various AGV weights and speeds were then assessed by the proposed regressional MKT model. Simulation results indicate that the maximum floor micro-vibrations of the target LCD factory fall within the VC-B and VC-C levels when AGV moves at a lower speed of 1.0 m/s, while they may exceed the acceptable VC-B level when AGV moves at a higher speed of 1.5 m/s. The simulated floor micro-vibration levels are comparable to those of typical LCD factories induced by AGVs moving normally at a speed between 1.0 m/s and 2.0 m/s. Therefore, the numerical algorithm that integrates a simplified sub-structural multi-span continuous beam model and a proposed regressional MKT moving force model can provide a satisfactory prediction of AGV-induced floor micro-vibrations in LCD factories, if proper parameters of the MKT moving force model are adopted.

Development of Housing Conceptual Framework through Changes in Korean Family Houses -Kitchen Lifespace(I)- (한국주거형태 변천과정에서 본 주거학의 생태학적 개념정립 제1부 부엌변천)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.3
    • /
    • pp.67-85
    • /
    • 1990
  • The purpose of this study was (1) to investigate changes in house and kitchen forms and behaviors in the kitchen area of Korean family houses from the Yi-dynasty to the present, and (2) to develop a housing conceptual framework on the basis of the ecosystem approach through analysis of changes in Korean family houses. The documentary research method wad used fro this study. The major findings were that the traditional Korean houses were composed of separate buildings and had various floor levels with the maru(a wooden floor) as the center of the open plan. The introduction of foreign style house forms from the era of enlightenment, in the year 1876 to the Korean war in 1950 changed traditional Korean houses into Korean-western style houses. More recent increased population and urbanization accelerated to change from the traditional Korean house form to an apartment style. At the present time, however, many kinds of house forms, from a highly modernized style with convenient facilities to a primitive style, which cannot even meet the basis needs of daily life, coexist together. The Kitchens in traditional Korean houses had no plumbing, drainage, or work centers. They had simple adobe furnaces which were used for cooking and for heating the ondol, a kind of panel heated floor by which the heat and smoke run under the floor to the chimney. This made the kitchen floor level lower than the floors of other spaces. The residents entered the kitchen through the madang(atrium). The influence of the western style kitchen, the development of technology, and improvements of nation-wide economic status have made today's kitchen space covenient and hygienic. The floor level of the kitchen was raised to the same level of other spaces. Formerly the major function of the kitchen was raised to the same level of other spaces. Formerly the major function of the kitchen space was cooking and heating floors. This had changed, and the kitchen is now, the place for family and social interaction. A housing conceptual framework was developed on the basis of these findings.

  • PDF

An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2011
  • To obtain a lower story height with a long span and better fire resistance, a new composite floor system using GFRP (glass-fiber-reinforced plastics) was proposed. This floor system consists of asymmetric steel with a web opening, a hollow core ball, concrete, and GFRP. To evaluate the flexural performance of the new composite floor system, an experiment was conducted. The test parameters were the presence of GFRP, the void ratio in relation to the hollow core balls, and the web opening. The test results showed that the resistance and stiffness of the specimen with GFRP were 10% higher than those of the reference specimen, and that fully composite action was accomplished up to the yielding point. After the attainment of the yield strength, the ductility of the specimen was reduced due to the stress concentration around the web openings. The slip between the concrete and steel beam, however, was small. Thus, in the design of the proposed new floor systems, it is desirable that the calculated resistance be reduced by 15%, for safety.

Effect of line and floor type on growth performance and feather characterization during the growth period of White Roman geese

  • Lin, Min Jung;Chang, Shen Chang;Chen, Tzu Jou;Lin, Wei Chih;Peng, Shao Yu;Lee, Tzu Tai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.9
    • /
    • pp.1455-1462
    • /
    • 2020
  • Objective: The purpose of this study was to investigate whether goose growth and feather characteristics are influenced by their line and feeding surroundings, inclusive of floor materials and types, since there are no reports regarding these factors. Methods: The 240 White Roman geese which were hatched and sex identified came from 3 commercial goose farms. They were randomly distributed to 24 pens depending on a completely random design. The study continued for 13 weeks and included 3 lines of commercial geese and 2 floor types (cement strip floor [CSF] or cement floor [CF]). Results: The day one gosling weight from A farm was lower than other two farms (96 g vs 107 and 115 g; p<0.001). Afterwards, the body weight, back length, keel length, chest girth and main wing feather length among 3 farms showed no significance difference prior to 12 weeks. The CF group showed heavier body weight, shorter back length, longer keel length, shorter chest girth and shorter main wing feather length than the CSF group prior to 12 weeks. The down weight in the CF was heavier than the CSF group (57.1 g vs 41.8 g; p<0.01) prior to 13 weeks. Conclusion: The body weight showed the positive relations for dry feather weight (r = 0.59), down weight (r = 0.69), percent of the down weight of live body weight prior to 13 weeks (r = 0.61).

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • v.37 no.5
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

Effects of transport time and feeding type on weight loss, meat quality and behavior of broilers

  • Fu, Yajie;Yin, Jingwen;Zhao, Ning;Xue, Ge;Zhang, Runxiang;Li, Jianhong;Bao, Jun
    • Animal Bioscience
    • /
    • v.35 no.7
    • /
    • pp.1039-1047
    • /
    • 2022
  • Objective: The purpose of this study is to determine the optimal time of transportation of floor-feed and scatter-feed broilers. Methods: Eighty healthy Arbor Acres (AA) broilers (21-day-old, 624.4 g, male, standard error = 6.65) were selected and randomly divided into two experimental groups (floor-feed and scatter-feed), then fed for three weeks. The experiment comprised a 2×4 factorial design with 2 feed patterns (floor-feed and scatter-feed) and 4 transport periods (2, 3, 4, and 5 h), and 4 replicates of 5 broilers (54-day-old, 2243 g, standard error = 46.65) was used to compare weight loss, meat quality and behavior index of different groups. Results: It appeared that drip loss, meat color and resting behavior of experimental broilers changed as length of transportation (p<0.05), however, weight loss and pH were not significantly transformed (p>0.05). Compared with floor-feed group, broilers in scatter-feed group had lower pH at 24 hours (3 h) and different behavioral indicators (p<0.05). Especially indicators after 3 h transportation, there were obvious differences between the two feeding modes in the behavior reaction of stress events before slaughter with different transport duration (p<0.05). The fluctuation of data on resting behavior with scatter-feed was significantly higher than that of floor-feed broilers. There was no interaction between transport time and different feeding methods for index tested of our experiment (p>0.05). Conclusion: Comprehensive analysis showed that the maximum transport duration of floor-feed and scatter-feed broilers should not exceed 3 h, and scatter-feed broilers were more likely prone to fear.

A Study on the Thermal Comfort Zone and Energy Use of Radiant Floor Heating by Residential Style and Clothing Level (생활특성과 착의량에 따른 바닥복사난방 공간의 열쾌적 범위 및 에너지 사용량에 관한 연구)

  • Kim, Sang-Hun;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.24-31
    • /
    • 2015
  • The purpose of this study is to provide the thermal comfort range according to the residential style and clothing level at radiant floor heating space, and compare the annual energy consumption and energy cost for each condition. Lower neutral point temperature has been stood for floor sitting style than chair sitting style, which appears that the thermal sensation was affected by local heat transfer between floor surface and the human body. The result of research indicates that neutral point temperature was in inverse proportion with the clothing level. It is interpreted that the increasing of clothing level results decrement of heat loss from human body, and is available to achieve same thermal comfort at lower room temperature. It was analyzed that the floor sitting style is more economical residential style than the chair sitting style, because the energy consumption of the floor sitting style is saved by 6.0% in average to compare with that of the chair sitting style. It is analyzed that energy consumption has been decreased by 13.5% with the clothing level of 1.2 Clo than with that of 1.0 Clo, and decreased by 18.0% than with that of 0.8 Clo, which explains that the energy saving can be achieved with the variation in life habit to increase the clothing level.

The Effect of Pelvic Floor Muscle Strengthening Exercise Treatment Program For Stress Incontinence of The Older Women (노인여성의 복압성요실금에 대한 골반저근육강화 운동치료 프로그램의 효과)

  • Gu, Hui-Seo;Park, Jeong-Mi
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.49-66
    • /
    • 2002
  • This study was designed to evaluate the effect of pelvic floor muscle strengthening exercise treatment program for the older women with stress incontinence. The researcher developed 8 weeks training program which was implemented at a social welfare center in Seoul. The exercise method followed the Kegel criteria. Verbal instructions were given to the subjects. Subjects were confirmed of the exercises and evaluated by description of the exercise method. Fourteen elderly women(mean age 75.7) with stress incontinence participated and completed this program. The training sessions were held twice a week and each session took 45 minutes ; 15 minutes for pelvic floor muscle strengthening program and 30 minutes for other physical therapy. Pelvic floor muscle strengthening exercise program was applied using verbal instruction and practice at social welfare center, twice a week and daily home exercise program were given to each individual. The results were as follows ; 1. There was significant decrease of lower urinary symptoms in the subjects (p = 0.00) 2 But there was no significant change in the sexual matters (p = 0.44) and the life style (p = 0.41) In conclusion, further study with larger sample group is suggested in order to confirm the study result. Because of limited sample size, the study results were not conclusive. But the pelvic floor muscle strengthening exercise treatment program could be a safe and effective program and is suggestive for the community residing older women with stress incontinence as a geriatric physical therapy intervention.

  • PDF

A Study of Radon Concentration in First Floor and Basement and Prediction of Annual Exposure Rate in Korea (국내 실내 라돈농도와 연간 피폭선량 예측에 관한 연구)

  • Lee, Jong-Dae;Kim, Yoon-Shin;Son, Bu-Soon;Kim, Dae-Seon
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.311-317
    • /
    • 2006
  • The purpose of this study was to investigate Rn concentration and annual radiation exposure level in the basement and first floor. The Rn Cup monitors were placed in different environments such as shopping stage, office building, Apartment, Hospital, house in Seoul from Match 1996 to April 1997 and CR-39 films were collected every two months. The mean radon concentration in the basement of house($88.6\;Bq/m^3$) showed the highest level among the areas, while radon concentration on the first floor of house($50.5\;Bq/m^3$) showed the higher than other areas. The annual radiation exposure dose that person on the floor / in the basement of differential place in the seoul can be exposed during living was estimated from 24.11 to 87.64 mRem/yr. This radiation dose is significantly lower than 130mRem maximum radiation dosage from the radon nuclide prescribed by the ICRP, with respect to the overall average exposure of the working adult. this study indicated that possible radon sources on the first floor / in the basement areas are radon intrusion from soil gas, construction materials, or ground water leaking. Further study is needed to quantitatively assess major contributions of radon-222 and health effect to radon exposure.

The Effects of Maintained Muscle Contraction of Abdominal and Pelvic Floor Muscles on 3D Pelvic Stability in Individuals with Chronic Low Back Pain During Gait

  • Yu, Min;Choi, Yu-Ri;Choi, Jeong-Eun;Jeon, Seong-Yeon;Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • PURPOSE: This study was designed to investigate the effects of keeping contraction of abdominal and pelvic floor muscles on 3D pelvic stability in individuals with nonspecific chronic low back pain (CLBP) during normal speed walking. METHODS: The subjects were 20 adults with CLBP deformity and had moderate pain intensity of the visual analog scale. A three-dimensional camera capture system was used to collect kinematic pelvic motion data with and without contraction of the abdominal and pelvic floor muscles during gait. The subjects were asked to walk on a walkway in the lab room and they were attached 40 reflective markers to their pelvic segment and lower extremities. A Visual3D Professional V6 program and Vicon Nexus software were used to analyze 3D pelvic kinematic data. RESULTS: There were significant differences between with and without contraction of the abdominal and pelvic floor muscles of the pelvic depression and the total pelvic motion in coronal plane during gait (p < .05). However, there were no significant differences in any of the maximal motion of the pelvic segment in sagittal and transverse motion plane according to the different muscle contraction conditions (p > .05). CONCLUSION: The results of this study suggest that maintaining co-contraction of the abdominal and pelvic floor muscles in individuals with CLBP increased pelvic stability and contributed to preventing excessive pelvic movements during gait.