• 제목/요약/키워드: Lower head failure

검색결과 68건 처리시간 0.038초

Failure simulation of nuclear pressure vessel under LBLOCA scenarios

  • Eui-Kyun Park;Jun-Won Park;Yun-Jae Kim;Kukhee Lim;Eung-Soo Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2859-2874
    • /
    • 2024
  • This paper presents the finite element deformation and failure simulation of a typical Korean high-power reactor vessel under a severe accident characterized by large break loss of coolant (LBLOCA) with in-vessel retention of molten corium through external reactor vessel cooling (IVR-ERVC) conditions. Temperature distributions calculated using Modular Accident Analysis Program Version 5 (MAAP5) as thermal boundary conditions were used, and ABAQUS thermal and structural analyses were performed. After full ablation, the temperature of the inner surface in the thinnest section remained high (920 ℃), but the stress remained relatively low (less than 6 MPa). At the outer surface, the stress was as high as 250 MPa; however, the resulting plastic strain was small owing to the low temperature of 200 ℃. Variations in stress, inelastic strain, and temperature with time in the thinnest section suggest that the plastic and creep strains are saturated owing to stress relaxation, resulting in low cumulative damage. Thus, the lower head of the vessel can maintain its structural integrity under LBLOCA with IVR-ERVC conditions. The sensitivity analysis of internal pressure indicates the occurrence of failure in the thinnest section at an internal pressure >9.6 MPa via local necking followed by failure due to high stresses.

노심용융사고시 원자로 압력용기 하반부 거동연구(II)

  • 임동철;정광진;황일순
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.600-605
    • /
    • 1997
  • Sandia National Laboratories(SNL)에서 수행된 원자로 용기의 고온, 고압 크리프 파괴 실험의 하나인 Lower Head Failure-1(LHF-1)에 대한 코드 해석을 수행하였다. 해석 코드로는 범용 유한요소 구조해석 코드인 ABACUS를 사용하였고, Idaho National Engineering Laboratory(INEL)의 크리프 데이터를 이용하였다. 크리프 해석에는 strain hardening 식을 적용하였고, 크리프 데이터를 적용하기 위해서 user subroutine을 개발하였다. 민감도 분석의 일환으로 내부 압력을 1.2배로 증가시킨 경우에 대해 수행한 해석 결과가 실험 결과와 유사하였다 해석 결과를 분석하여 현 크리프 데이터의 절대적 부족을 확인하였고, 크리프데이터 생산을 위한 크리프 시험을 계획하였다.

  • PDF

Clinical outcomes of synchronous head and neck and esophageal cancer

  • Park, Jae Won;Lee, Sang-wook
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.172-178
    • /
    • 2015
  • Purpose: To investigate clinical outcomes of synchronous head and neck and esophageal cancer (SHNEC). Materials and Methods: We retrospectively reviewed 27 SHNEC patients treated with curative intent at a single institution. The treatment modality for individual cases was usually determined on a case by case basis. Results: The median follow-up duration for the surviving patients was 28.2 months. The most common site of head and neck cancer was hypopharyngeal carcinoma (n = 21, 77.7%). The lower esophagus was the most common location of esophageal carcinoma (n = 16, 59.3%). The 2-year progression-free survival (PFS) and overall survival (OS) rates were 57.5% and 39.6%. Major pattern of failure was locoregional recurrence in the study patients. Esophageal cancer stage, the Eastern Cooperative Oncology Group (ECOG) performance status, and pretreatment weight loss were significant prognostic factors for OS in univariate analysis. Treatment-related death was observed in two patients, and one patient developed a grade 4 late treatment-related complication. Conclusion: Although the survival outcome for SHNEC is poor, long-term survival might be achievable with aggressive treatment with stage I-II esophageal cancer and good performance.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

한국인 갑상선 유두상암종 환자에서 XPC-PAT 유전자 다형 (XPC-PAT Polymorphism in Korean Thyroid Papillary Carcinoma)

  • 태경;이근영;김희옥;이용섭;이형석;안유헌
    • 대한두경부종양학회지
    • /
    • 제22권2호
    • /
    • pp.117-122
    • /
    • 2006
  • Background and Objectives : Thyroid carcinoma is the sixth commonest cancer in Korea and the papillary carcinoma is the most common type(88%) of the malignant thyroid tumors. Bulky DNA adducts formed by the carcinogens are repaired by DNA repair process, but failure to repair this DNA damage can cause mutations in oncogenes and tumor suppressor genes resulting in tumor formation. The xeroderma pigmentosum group C(XPC) gene is essential for this repair procedure and the XPC-PolyAT(PAT) polymorphisms may alter DNA repair capacity(DRC) and genetic susceptibility to cancer. Subjects and Methods : In a case-control study of 113 Korean patients with pathologically diagnosed thyroid papillary carcinoma and 65 control subjects, we investigated the association between the three XPC-PAT gene polymorphisms and thyroid papillary cancer susceptibility. Results : The frequency of the variant XPC-PAT allele was lower in the cases(0.349) than in the controls (0.423), but the difference was not significant(p=0.140). Using logistic regression adjusting for age and sex, risk for thyroid papillary cancer was not increased in the XPC-PAT-/+ and XPC-PAT+/+ compared to XPCPAT-/-(adjusted overall odds ratio[95% confidence intervals;95%CI]=0.52[0.26-1.03] and 0.62 [0.22-1.75], respectively; trend test, p=0.167). Conclusion : There are no relationship between the XPC-PAT polymorphism and the risk of thyroid papillary carcinoma in Korean population. Based on our results, XPC-PAT polymorphism do not modulate genetic susceptibility to thyroid papillary cancer.

엔진 배기매니폴드의 열응력 발생에 관한 설계 인자들의 이론적 연구 (Theoretical Study of Design Parameters for the Thermal Stress in Engine Exhaust Manifold)

  • 최복록
    • 한국기계가공학회지
    • /
    • 제6권1호
    • /
    • pp.50-56
    • /
    • 2007
  • Exhaust manifold is generally subjected to thermal cycle loadings ; at hot condition, large compressive plastic deformations are generated, and at cold condition, tensile stresses are remained in highly deformed critical zones. These phenomena originate from the fact that thermal expansions of the runners are restricted by inlet flange clamped to the cylinder head, because the former is less stiff than the latter and, the temperature of the inlet flange is lower than that of the runners. Since the failure of an exhaust manifold is mainly caused by geometric constraints between the cylinder head and the manifold, the thermal stress can be controlled by geometric factors. The generic geometric factors include the inter distance (2R), the distance from the head to the outlet (L), the tube diameter(d) and the tube thickness (t). This criteria based on elastic analysis up to onset of yield apparently indicate that the pre-stress also reduces the factor; however, high temperature relaxation may reduce this effect at later operation stage.

  • PDF

미세수술을 이용한 재건수술에서 정맥이식의 유용성 (Usefulness of Vein Grafts in Reconstructive Microsurgery)

  • 안희창;안덕균
    • Archives of Reconstructive Microsurgery
    • /
    • 제5권1호
    • /
    • pp.46-55
    • /
    • 1996
  • The purpose of this study is to investigate if there is a higher rate of free flap failure in cases of vein grafts compared to non-vein graft, and to analyze the clinical usefulness and necessity in elective free flap surgery. We have used 24 vein grafts in 208 free flaps from May, 1986 until August, 1995. Vein grafts were from 2cm to 50cm in length between the recipient and donor vessels. Reconstructed sites were 10 lower extremities, 8 head and neck, 4 hand, and 2 trunk. Vein grafts were used 14 for arterial, 6 venous, 4 in both arterial and venous anastomoses. We intentionally used long vein grafts longer than 5cm for improved blood flow in cases of peripheral vascular disease, radionecrotic wounds, lower leg trauma. Short vein grafts of about 3cm in length were used to overcome the shortage of vascular length in cases of unexpected vessel anomaly, short donor vessel, and difficult access to recipient vessels after radical neck dissection. All veins were carefully handled with ligation of very small branches and were transferred to the recipient site without irrigation. 8 flaps were failed out of a total of 208 free flaps, however there was no failure among the 24 cases that needed vein grafts between the donor and recipient vessels. Success rates between non-vein grafts free flaps and vein graft free flaps were 95.6%(8/184) and 100%(0/24). Even though the vein grafts increase the operation time and the number of anastomoses, they do not result in any increased failure rate of free flap surgery(4.4% versus 0%). In addition to the reducing tension between recipient and donor vessels, the surgeon can select better recipient vessels with excellent blood flow so that vein grfats in microsurgery can provide a high success rate of free flaps.

  • PDF

유한요소법을 이용한 대퇴 골두내 무혈성 괴사증의 다양한 수술적 기법에 대한 생체역학적 분석 (A Biomechanical Analysis of Various Surgical Procedures for Osteonecrosis of the Femoral Head using a Finite Element Method)

  • 김정성;이성재;신정욱;김용식;최재봉;김양수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.374-378
    • /
    • 1997
  • Operative procedures such as core drilling with and without fibular bone grafting have been recognized as the treatment methods for osteonecrosis of femoral head(ONFH) by delaying or preventing the collapse of the femoral head. In addition, core drilling with cementation using polymethylmethacrylate (PMMA) has been proposed recently as another surgical method. However, no definite treatment modality has been found yet while operative procedures remain controversial to many clinicians In this study, a finite element method(FEM) was employed to analyze and compare various surgical procedures of ONFH to provide a biomechanical insight. This study was based upon biomechanical findings which suggest stress concentration within the femoral head may facilitate the progression of the necrosis and eventual collapse. For this purpose, five anatomically relevant hip models were constructed in three dimensions : they were (1) intact(Type I), (2) necrotic(Type II), (3) core drilled only(Type III), (4) core drilled with fibular bone graft(Type IV), and (5) core drilled with cementation(Type V). Physiologically relevant loading were simulated. Resulting stresses were calculated. Our results showed that the volumetric percentage subjected to high stress in the necrotic cancellous region was greatest in the core drilled only model(Type III), followed by the necrotic(Type II), the bone graft (Type IV), and the cemented(Type V) models. Von Mises stresses at the tip of the graft(Type IV) was found to be twice more than those of cemented core(Type V) indicating the likelihood of the implant failure. In addition, stresses within the cemented core(Type V) were more evenly distributed and relatively lower than within the fibular bone graft(Type IV). In conclusion, our biomechanical analyses have demonstrated that the bone graft method(Type IV) and the cementation method(Type V) are both superior to the core decompression method(Type III) by reducing the high stress regions within the necrotic cancellous bone. Also it was found that the core region filled with PMMA(Type V) provides far smoother transfer of physiological load without causing the concentration of malignant stresses which may lead to the failure than with the fibular bone graft(Type IV). Therefore, considering the above results along with the degree of difficulties and risk of infection involved with preparation of the fibular bone graft, the cementation method appears to be a promising surgical treatment for the early stage of osteonecrosis of the femoral head.

  • PDF

병기 T1 성문암의 방사선치료 (Radiation Therapy in T1 Glottic Cancer)

  • 정은지;이상욱;이창걸;김귀언;김광문;홍원표
    • 대한두경부종양학회지
    • /
    • 제12권1호
    • /
    • pp.26-31
    • /
    • 1996
  • Radiation therapy in T1 glottic cancer offers an excellent cure rate with preservation of voice. From 1983 to 1992 eighty nine patients with TNM staged T1N0M0 invasive squamous cell carcinoma of the glottis were treated at the Dept. of Radiation Oncology, Yonsei Cancer Center, Yonsei University. There were 84 men and 5 women with median age of 59 years. All patients were treated either with Co-60 teletherapy unit or 4MV linear accelerator with an median dose of 6400 cGy(6000-7000 cGy), 200 cGy per day, 5 days in a week. Fourteen local failures have been observed and the median time to local recurrence was 17 months. There were no nodal failure without local recurrence or distant metastases. The 5 year local control rate was 84.3%. The 5 year actuarial surivival rate and the 5 year disease free survival rate were 89.2%, 87.5%, respectively. The 5 year actuarial survival rate and the 5 year disease free survival rate of the nineteen patients with anterior commissure involvement were 77.8% and 74.5% which were lower than those of seventy patients without anterior commissure involvement(91.6%, 90.6%)(p < 0.05). Among the several influencing factors, anterior commissure involvement was the significant prognostic foctor. Final local control rate, taking into account the salvage surgery, was 89.9% at 5 years.

  • PDF

초소형 광디스크 드라이브용 관성 래치 설계 (Inertia Latch Design for Micro Optical Disk Drives)

  • 김경호;김유성;이승엽;유승헌;김수경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1157-1164
    • /
    • 2003
  • Dynamic Load/unload (L/UL) mechanism is an alternative to the contact start stop (CSS) technology which eliminates stiction and wear failure modes associated with CSS. Other benefits of L/UL include increased areal density due to smooth disk surfaces, thinner overcoats, and lower head flying height Improved shock resistance due to elimination of head slap, and reduced power consumption. Inertia latch mechanism becomes important for mobile disk drives because of non operating shock performance. Various types of latch designs have been introduced in hard disk drives to limit a rotary actuator from sudden uncontrolled motion. In this paper, a single spring inertia latch is introduced for a small form optical disk drive, which uses a rotary actuator for moving an optical pick-up. A new small inertia latch with single spring is designed to ensure both feasible and small size. The shock performance of the new inertia latch is experimentally verified.

  • PDF