• Title/Summary/Keyword: Lower Tooth

Search Result 682, Processing Time 0.027 seconds

EFFECT OF C-FACTOR AND LAYERING TECHNIQUE ON THE CONTRACTION FORCE OF COMPOSITE RESIN RESTORATION TO TOOTH SURFACE (C-factor와 충전법이 복합레진의 중합 수축에 의한 치질에서의 수축 응력에 미치는 영향)

  • Lee, Bong-Kyu;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.233-243
    • /
    • 2006
  • The aim of this study was to investigate the relationship between the C-factor and shrinkage strain values of composite resin and examine the strain values in different incremental filling techniques. Experiment consisted two aims. First, we compared with strain value in two different C-factors(3.7 and 1.0). Second, we examined the strain values in three different filling techniques. The results of the present study can be summarized as follows : 1. High C-factor groups showed higher contraction stress values than low C-factor groups at 900 sec after polymerization. 2. Hybrid resin showed higher contraction stress values than flowable resin in high C-factor cavities. But contraction stress was not revealed significant difference between hybrid resin and flowable resin in low C-factor cavities (P>0.05). 3. Bulk felling with hybrid resin(Group 1) showed high contraction stress and lining with flowable resin followed hybrid resin (Group 5) showed lower contraction stress. 4. Contraction stress were increased during 900 sec after polymerization in high C-factor groups but decreased gradually after 900 sec. 5. Low C-factor groups showed tight marginal seal between resin and cavity wall but high C-factor groups showed gaps formed between resin and cavity wall in part. On the basis above results, layering techniques in high C-factor cavity showed advantages in reducing contraction stress and gap formation between cavity wall and resin restoration.

  • PDF

DIRECT PULP CAPPING WITH BONDING RESIN (접착용 레진을 이용한 유치의 직접 치수복조술에 관한 연구)

  • Cho, Hae-Sung;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.165-172
    • /
    • 2006
  • A direct pulp capping with different medicaments has been attempted for a long time. The most commonly used among those is the calcium hydroxide. In primary teeth, however, a success rate of direct pulp capping with calcium hydroxide has been reported to be lower than that of pulpotomy. The disappointing results of calcium hydroxide have prompted the search for other capping materials. Lately, several researchers suggested an application of adhesive resin-based composite systems as a capping material. They claimed that when an exposed vital pulp is capped directly with bonding resin, the pulp tissue is free of inflammation or necrosis without clinical symptoms. The aim of this study was to compare short-term effects of the bonding resin which was applied on the mechanically exposed vital pulp tissue and those of direct pulp capping with calcium hydroxide. The second objective was to compare success rates of the primary teeth which already underwent physiologic root resorption and those of the teeth which had not undergone physiologic root resorption yet, in each capping material groups. The vital, healthy pulp of forty-one primary teeth were exposed mechanically during a cavity preparation. They were divided into two groups: Group 1(n=21) underwent capping with bonding resin, and group 2(n=20) underwent capping with calcium hydroxide. Then these two groups were subdivided into two groups in each : the teeth which show physiologic root resorption and the teeth without root resorption. All of the sample teeth were restored with composite resin. Clinical evaluations such as percussion test, ice test, EPT, were recorded and also before- and after- standard x-ray films were compared and evaluated to decide whether the case was successful or not. Evaluation was performed at least 3 months after the capping materials. The results were as follows 1. There was no difference in success rate between group 1 and group 2. 2. Success rate of the teeth with physiologic root resorption was higher than that of the teeth without physiologic root resorption in group 1 and group 2. 3. There was no difference in success rate between anterior teeth and posterior teeth.

  • PDF

Association of Periodontitis with Serum Vitamin D Level among Korean Adults (한국 성인의 비타민 D와 치주질환의 관계)

  • Kim, Jaemin;Hwang, Hee-jin
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.210-217
    • /
    • 2018
  • Periodontal disease is a chronic inflammatory disease that affects quality of life and nutrition. Several studies have demonstrated a link between periodontal disease and low bone density, and vitamin D is expected to have a beneficial effect on periodontal disease as well as on bone mineral density and anti-inflammatory effects. The purpose of this study was to identify the association between periodontal disease and vitamin D because the results are different in some studies and there is a lack of research in Korea. In this study, we conducted a multiple linear regression analysis of 8,783 subjects among 23,626 subjects who were older than 20 years of age, who had serum vitamin D levels and periodontal disease, who had three years of the National Health and Nutrition Survey that was conducted in Korea from 2012 to 2014. We examined the relationship between serum vitamin D levels and periodontal disease. Tooth loss and vitamin D levels were negatively correlated (${\beta}=-0.028$, p=0.008). In addition, the prevalence of periodontal disease was found to be higher in men younger than 50 years of age with lower vitamin D levels (Q1: 1.769 [1.125~2.782], Q2: 1.182 [0.743~1.881], Q3: 0.676 [0.400~1.881]; p=0.001). Low vitamin D levels and periodontal disease are common diseases in primary care. Vitamin D supplementation is expected to have favorable effect on periodontal disease and falls, osteoporosis, osteoarthritis, and cancer. Therefore, patients with periodontal disease may benefit from periodic vitamin D management to improve quality of life as well as to manage periodontal disease. In addition, as shown in this study, not only elderly individuals, but also men younger than 50 years of age are related to periodontal disease, so there should be interest in controlling the levels of vitamin D in adults.

Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis (다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례)

  • Kang, Jeong Kyung;Nam, Gi Hoon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • There are several treatment options for rehabilitation of partial edentulism including the use of conventional or implant-retained fixed prostheses. However, such prosthetic options cannot always be possible because of compromised general and oral health (i.e. loss of supporting tissues, medical reasons, extensive surgical protocol and osseointegration failure of dental implant) as well as the affordability of patients. In some cases, removable partial denture provides easier access for oral hygiene procedures and the ability to correct discrepancies in dental arch relationships than implant fixed prosthesis. Recently, Implant Supported Removable Partial Denture (ISRPD) where to place dental implant in strategic position has been suggested to improve the limitation and shortcomings of conventional RPD. ISPRD can overcome mechanical limition of conventional RPD by placing implant in a favorable position and can be cost-effective, prosthetic solution for partially edentulous patients who are not immediate candidates for extensive, fixed implant supported restorations. Incorporation of dental implants to improve the RPD support and retention and to enhance patient acceptance should be considered when treatment planning for RPD. In this case, 59 years old male patient who received dental treatment of implant fixed prosthesis on both side of the upper jaw and implant overdenture on lower jaw showed implant abutment screw fracture on #15i and osseointegration failure on multiple number of implants. After removing failed implants, we planned ISRPD using #15i,24i,25i,26i and #23 natural tooth for RPD abutment. We fabricated #23 surveyed crown,#24i=25i=26i surveyed bridge and #15i gold coping for support,retention and stability for RPD. Periodic follow up check for 2years has been performed since the ISRPD delivery to the patient. No sign of screw loosening, fracture or bone resorption around abutment implants were detected.

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

AN INVESTIGATION OF TRAUMATIC DENTAL INJURIES IN CHILDREN (소아의 치아와 지지조직 외상에 관한 분석)

  • Baik, Byeong-Ju;Yang, Yeon-Mi;Yang, Cheol-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.600-612
    • /
    • 2001
  • The purpose of this study is concerned with an investigation of the actual condition of traumatic injuries of teeth and supporting structures in children to set up possible criteria for prevention and treatment of injured teeth. The materials consisted of the clinical records of 431 traumatically injured teeth of 212 children, accumulated during two years from the first of April in 1998 to the end of March in 2000, supplied from the Dept. of Pediatric Dentistry, Chonbuk National University Hospital. The incidence of injuries in boys was extremely high for permanent teeth, twice as high as in girls. Accidents to primary teeth were most common from 1 to 2 years of age and to permanent teeth were most from 8 to 9 years of age. The most common cause of trauma was a fall for both primary and permanent teeth, followed by collision. The anterior teeth in maxilla was most frequently affected by trauma in both the primary and permanent teeth. The most common type of trauma were loosening for the primary teeth, followed by luxation types which included the intrusion, displacement and extrusion and complete avulsion types. For the permanent teeth, the most common type of trauma were tooth fracture. The most common trauma of soft tissue was laceration of upper lip, lower lip and gingiva of maxilla Concerning treatment at the first visit, primary teeth with only loosening and concussion were not usually treated. Permanent teeth were often treated by crown restorations for crown fractures and by endodontic procedures for pulpal exposure. Though we could elucidate actual condition of traumatic injuries of teeth in children, we should make a follow-up survey to ensure the prognosis of injured teeth and establish the most desirable criteria for traumatized teeth in children.

  • PDF

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Comparison of Color Stability and Surface Roughness of 3D Printing Resin by Polishing Methods (연마 방법에 따른 3D 프린팅 레진의 색조 안정성과 표면 조도의 비교)

  • Heeju Kim;Yujin Kim;Jongsoo Kim;Joonhaeng Lee;Mi Ran Han;Jisun Shin;Jongbin Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.205-216
    • /
    • 2023
  • This study aimed to compare the color stability and surface roughness of three-dimensional (3D) printing resin according to polishing methods. 3D-printed resin specimens were fabricated at TC-80DP (Graphy, Seoul, Korea) with a stereolithography 3D printer, and the specimens were divided into three groups, each of which was not polished, was polished using Enhance®, and was polished using a Sof-LexTM disc. The CIE L*a*b* value and the surface roughness of each group were measured and immersed in artificial saliva and orange juice after 0, 1, 7, 30, and 60 days, and the color difference (ΔE*) was calculated. As a result of the study, no noticeable color change was observed in artificial saliva, but a noticeable color change was demonstrated in orange juice after 60 days of immersion, and the difference was significant. In the Sof-LexTM group, surface roughness according to the solution was found to be significantly higher in the orange juice than that in artificial saliva. No significant difference in color change was found according to the polishing method, but surface roughness was significantly lower in the Sof-LexTM group than both that of the unpolished group and that of the Enhance® group. Nevertheless, all groups exhibited clinically acceptable properties regardless of their higher surface roughness than the threshold for plaque accumulation. Overall, this study recommends utilizing Sof-LexTM for polishing 3D printing resin when used in primary anterior tooth coverage.