• Title/Summary/Keyword: Lower Tooth

Search Result 682, Processing Time 0.039 seconds

Association between the severity of hypodontia and the characteristics of craniofacial morphology in a Chinese population: A cross-sectional study

  • Xin Xiong;Jiaqi Liu;Yange Wu;Chengxinyue Ye;Qinlanhui Zhang;Yufan Zhu;Wenke Yang;Jun Wang
    • The korean journal of orthodontics
    • /
    • v.53 no.3
    • /
    • pp.150-162
    • /
    • 2023
  • Objective: To investigate craniofacial differences in individuals with hypodontia and explore the relationship between craniofacial features and the number of congenitally missing teeth. Methods: A cross-sectional study was conducted among 261 Chinese patients (males, 124; females, 137; age, 7-24 years), divided into four groups (without hypodontia: no teeth missing, mild: one or two missing teeth, moderate: three to five missing teeth, severe: six or more missing teeth) according to the number of congenitally missing teeth. Differences in cephalometric measurements among the groups were analyzed. Further, multivariate linear regression and smooth curve fitting were performed to evaluate the relationship between the number of congenitally missing teeth and the cephalometric measurements. Results: In patients with hypodontia, SNA, NA-AP, FH-NA, ANB, Wits, ANS-Me/N-Me, GoGn-SN, UL-EP, and LL-EP significantly decreased, while Pog-NB, AB-NP, N-ANS, and S-Go/N-Me significantly increased. In multivariate linear regression analysis, SNB, Pog-NB, and S-Go/N-Me were positively related to the number of congenitally missing teeth. In contrast, NA-AP, FH-NA, ANB, Wits, N-Me, ANS-Me, ANS-Me/N-Me, GoGn-SN, SGn-FH (Y-axis), UL-EP, and LL-EP were negatively related, with absolute values of regression coefficients ranging from 0.147 to 0.357. Further, NA-AP, Pog-NB, S-Go/N-Me, and GoGn-SN showed the same tendency in both sexes, whereas UL-EP and LL-EP were different. Conclusions: Compared with controls, patients with hypodontia tend toward a Class III skeletal relationship, reduced lower anterior face height, flatter mandibular plane, and more retrusive lips. The number of congenitally missing teeth had a greater effect on certain characteristics of craniofacial morphology in males than in females.

Fabrication of complete denture using conventional method and monolithic digital denture system: a case report (전통적 제작법과 모놀리식(monolithic) 디지털 의치 시스템을 이용한 상·하악 총의치 동시 수복 증례)

  • Young-Baek Park;Ga-Hyun Lee;Young-Gyun Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.6-19
    • /
    • 2024
  • With the advancement of Computer-Aided Design/Computer-Aided Manufacturing (CAD-CAM) technology, fabrication of dentures using this technology has gained popularity. As one of CAD-CAM technologies, digital complete denture system has been introduced, which fabricates complete dentures using subtractive manufacturing of monolithic block containing both the color of a denture base and an artificial tooth. In this case, two pairs of upper and lower dentures were fabricated for two patients. Two pairs of complete dentures were fabricated for a 74-year-old male and a 73-year-old female respectively by conventional denture fabrication method and digital method of milling. To obtain a digital complete denture, monolithic block (Ivotion, Ivoclar Vivadent, Schaan, Liechtenstein) was chosen for the materials to fabricate the digital complete dentures. An individual tray was designed using CAD software and manufactured by 3D printing technique. The final impression and interocclusal relationship were recorded using the fabricated individual tray. The final impression was scanned, and the complete denture design and try-in denture were 3D printed using CAD-CAM software. Subsequently, the monolithic block was milled, and the final dentures were fabricated and tried on patients. Previously mentioned two patient cases compared and analyzed stability, fit, speaking, mastication, aesthetics, and patient satisfaction of two pairs of dentures: one fabricated using CAD-CAM system and the other using traditional methods. This was performed to evaluate and report the findings from both denture-making approaches.

The effect of a static magnetic field of Nd-Fe-B magnet on alkaline phosphatase activity of MC3T3-E1 cells (Nd-Fe-B 자석의 정자기장이 MC3T3-E1 세포의 alkaline phosphatase 활성도에 미치는 영향)

  • Kim, Sook-Hee;Kwon, Oh-Won;Ryoo, Hyun-Mo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.205-214
    • /
    • 2000
  • Recently, the magnetic force has been considered as a method for a more efficient tooth movement. The purpose of this study was to evaluate the effects of different static magnetic fields of Nd-Fe-B magnet on MC3T3-E1 cells by measuring the alkaline phosphatase activity and observing the amount of stained alkaline phosphatase. For measuring of alkaline phosphatase activity, MC3T3-E1 cells were seeded in first and third row of 12 well culture plates. And Nd-Fe-B magnets were positioned under the first column of first and third row to apply different static magnetic fields(first column:100mT ; second column:4.6mT ; third column:0.5mT ; forth column:0.0mT) to the cells for 7, 13, 19, and 25 days. For staining of alkaline phosphatase, MC3T3-E1 cells were seeded in 100mm culture plates. And Nd-Fe-B magnets were positioned under the corner of plates to apply different static magnetic fields(magnet side:100mT : the opposite side:0.5mT) to the cells for 7, 13, 19, and 25 days. The results were as follows : 1. ALP activity was increased until day 19 in biochemical determination as well as in histochemical staining, 2. The application of higher magnetic field(100mT) suppressed ALP activity at day 13, 19, 25. On the contrary, the application of the lower magnetic field(4.6mT, 0.5mT) significantly enhanced the ALP activity. 3. Consistent with enzyme assay, histochemical staining of ALP also demonstrated that higher magnetic field(100mT) suppressed ALP activity, lower one(0.5mT) enhanced.

  • PDF

Regional load deflection rate of multiloop edgewise archwire (Multiloop edgewise arch wire의 부위별 하중변형률)

  • Kim, Byoung-Ho;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.673-688
    • /
    • 1999
  • This study was conducted in order to analyze the mechanical characteristics of multiloop edgewise archwire (MEAW). The purposes were 1) to compare load deflection rate (LDR) of MEAW with that of various other arch wires in the individual interbracket span, 2) to compare the wire stiffness in the interbracket span with that in the multi-L-loop region (the span from distal border of the bracket of the lateral incisor to the mesial border of the buccal tube of the second molar), and 3) to verify the experimental results with theoretically derived formula. The single L-loops of five different horizontal lengths and multi-L-loops for the upper and lower arches were made out of .$016\times.022$ permachrome stainless steel wire. Straight segment of plain stainless steel, TMA and NiTi wire of the same dimension were prepared. The LDR was measured using Instron model 4466 with the load cell of 50N capacity at cross head speed of 1.0mm/min, and maximum deflection of 1.0mm. Five specimens were tested under each experimental condition. The wire stiffness number for each interbracket region and multi-L-loop region was calculated from the LDR and the interbracket spans. By dividing the theoretical model of multi-L-loop into 35 linear segments, the energy stored in each segment was obtained. Then the LDR and wire stiffness of single L-loop and multi-L-loop were calculated and compared. The findings were as follows : 1) The average LDR of MEAW in the individual interbracket region was 1/1.53 of that of the NiTi,1/2.47 of TMA and 1/5.16 of the plain stainless steel wire. 2) The wire stiffness of MEAW in the multi-L-loop region was 1.53 times larger than that in the interbracket region, and the LDR was almost twice as large as that of NiTi in that region. 3) According to the theoretically derived equation, the wire stiffness of the single L-loop was lower than that of multi-L-loop. The results of this study suggest that MEAW has the unique mechanical Property which could allow individual tooth movement and transmit elastic force effectively through the entire arch wire.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

LONG-TERM EVALUATION OF A $SnF_2$ GEL FOR CONTROL OF GINGIVITIS AND DECALCIFICATION IN ADOLESCENT ORTHODONTIC PATIENTS (청소년 교정환자들의 치은염 및 치아탈회 조절을 위해 사용한 겔형 불화주석($SnF_2$ gel)의 장기간 평가)

  • Boyd, Robert L.;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.235-245
    • /
    • 1995
  • The purpose of this paper is to review two recently reported, long-term studies of several chemical methods to control gingivitis and decalcification in adolescent orthodontic patients. The first study(gingivitis study) was designed to determine whether conventional toothbrushing and twice daily use of a brush-on 0.4 per cent $SnF_2$ gel containing more than 90 per cent available $Sn^{2+}$ would be more effective for controlling plaque accumulation and gingivitis in the presence of orthodontic appliances than conventional toothbrushing alone. The second study(decalcification study) was designed to compare the effectiveness of controlling decalcification in orthodontic patients with either a II00 ppm F tooth paste used alone, this same toothpaste and a 0.05 percent NaF rinse or this toothpaste and a 0.4 percent $SnF_2$ gel. In the gingivitis study, sixty-five consecutively treated adolescents who were to receive full-mouth fixed orthodontic appliances were assigned to two groups according to age and sex criteria. In the decalcification study an additional 30 subjects(95 total) were similarly assigned to a third group. The first group(control, n=35) used only toothbrushing with a standard fluoride(1100 ppm F) toothpaste. The second group used toothbrushing with a similar dentifrice supplemented with a 0.4 percent $SnF_2$ gel($SnF_2$ gel group, n=30) used twice daily for the entire 18-month study period. The third group(in the decalcification study only) used a similar toothpaste and 0.05 percent NaF rinse(NgF rinse group, n=30). Clinical assessments of plaque accumulation using the Plaque Index, gingival inflammation using the Gingival Index, and coronal staining were completed single-blinded before appliances were placed and 1, 3, 6, 9, 12 and 18 months after appliances were placed. Decalcification was assessed single blind on all labial surfaces of all erupted teeth before appliances were placed and 3 months after appliances were removed. The results of the gingivitis study indicated that the $SnF_2$ gel gorup had significantly lower scores for the Plaque Index(p<0.01) and Gingival Index(p<0.001) at all examinations during orthodontic treatment than did the control group. In the $SnF_2$ gel group, one subject developed mild coronal staining and two subjects developed moderate staining. In the decalcification study, when pre-treatment levels of decalcification were subtracted from post-treatment values, significantly lower decalcification scores(p<0.05) were found for both whole mouth and first molars in the NaF rinse and gel groups as compared with the control gorup(toothpaste alone). Although the gel group consistently had less decalcification than the rinse group, this difference only approached statistical significance.

  • PDF

COMPARISON OF MICROLEAKAGE IN SEALANT REPAIRED WITH DIFFERENT SURFACE TREATMENT (파손된 치면열구전색제의 수리 방법에 따른 미세누출 비교)

  • Kang, Myung-Bong;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.204-214
    • /
    • 2007
  • The aim of this study was to investigate whether differences in surface treatment prior to repair influenced the seal of a resin fissure sealant placed on the occlusal surfaces of permanent molar teeth. One hundred and twenty extracted human molars were selected and a light curing sealant was placed on their occlusal surface following cleaning by prophylaxis and acid etching. The teeth were deliberately damaged, and then stored in artificial saliva for four weeks. Sixty teeth with the desired morphology of sealant failure were randomly divided into four groups where one group was treated with only etching agent, another by only air-abrasion, another by applying an etching agent followed by a bonding agent, and the last by air-abrasion followed by a bonding agent each. After sealant application, the samples were thermocycled and the degree of microleakage was determined. The results were as follows : 1. In the sealant/sealant interface group 2(0.22), 4(0.23) using air-abrasion showed a significantly lower microleakage score than group 1(0.38), 3(0.35) using an etching agent(p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 2 and groups 3, 4. 2. In the sealant/tooth interface, group 3(0.20), 4(0.20) which used a bonding agent showed a significantly lower microleakage score than group 1(0.35), 2(0.40) (p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 3 and groups 2, 4. 3. In SEM examination, while sealant surfaces treated with etching did not result in highly rough surfaces, those treated with air-abrasion did show rough surfaces.

  • PDF

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF

Effects of bisphosphonate and indomethacin on alveolar bone remodeling in rats (Bisphosphonate와 Indomethacin이 백서 치조골의 골개조에 미치는 영향)

  • Cho, Myeong-Sook;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.163-174
    • /
    • 1996
  • The purpose of this study was to examine the effects of bisphosphonate and indomethacin, blockers of bone resorption with different mechanisms, on alveolar bone remodeling. Male rats were divided into control, bisphosphonate and indomethacin groups, and then each group was divided info an experimental side and a control side according to the force application. Bisphosphonate(6.3mg/kg,$2.52x10^{-2}mol/L$) and indomethacin (9mg/kg, $2.52x10^{-2}mol/L$) were injected 6 hours and 1 hour before or 24 hours after the force application. The rats were killed 72 hours after the force application and histologic examination was perfomed. The values of serum acid phosphatase and lactate dehydrogenase were also measured in the control md experimental groups treated with bisphosphonate or indomethacin 1 hour before the force application. In the experimental side, the least number of osteoclasts was noted in the groups treated 1 hour before the force application with indomethacin or bisphosphonate, while there were no differences between the control and the groups treated with drugs 6 hours before or 24 hours after the force application. In the control side, the number of osteoclasts was not inecreased with no differences among the groups. Histologic examination revealed a severe alveolar bone resorption in the control group and the groups treated with indomethacin 6 hours before or 24 hours after the force application. Indomethacin treatment 1 hour before the force application and bisphosphonate treatment at any time significantly attenuated the bone resorption. Electron microscopically, ruffled border and clear zone of osteoclasts were observed in the control and indomethacin groups, while some osteoclasts were detached from the bone surface and exhibited dull cellular projections in the bisphosphonate groups. The bisphosphonate and indomethacin groups showed lower values of acid phosphatase and lactate dehydrogenase than the control group. The acid phosphatase value in the bisphosphonate group was lower than that in the indomethacin group, whereas there was no difference in the lactate dehydrogenase value between the groups. These results suggest that bisphosphonate reduces the activity of osteoclasts as well as the number of osteoclasts and that indomethacin reduces the number of osteoclasts without affecting the activity of osteoclasts. Bisphosphonate has a larger inhibitory effect on bone resorption md thus less limitation in the application time than indomethacin.

  • PDF

Understanding of the Workers in the North Area of Ulsan on the Oral Health and Hygienic Status (울산시 일부 생산직 근로자의 구강보건 인식에 대한 조사연구)

  • Lee, Ga-Ryeong
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.117-126
    • /
    • 2004
  • For a month of September, 2004, a questionnaire regarding dental hygiene was distributed to 165 workers of Ulsan area. A total of 125 questionnaire were analyzed: 102 collected of the distributed 165 pieces, and 23 questionnaires reported by patients of a dental clinic in Dong-gu, Woolsan. The result is as follows; (1) Labor workers of Ulsan have thought that they are in good dental health, 44.1% of respondents, following by those who they believe they are in moderate health and those who they think are in poor condition. 89.0% of total workers have experienced dental treatment. (2) Regarding the location of dental treatment, 85.0% of respondents have pointed out dental hospitals and clinics, while 3.9% have indicated that they had treatment from unlicensed dentists. Specifically, workers in their 40s over have ever experienced dental treatment by unlicensed dentists. Those who think they are in poor dental condition have tended to have more dental treatment by unlicensed dentists. (3) Regarding the reason that they put off the treatment, 59.1% of respondents have indicated that they have no time to have the treatment, following by economic burden and the lack of confidence in dentists. When they have tooth aches or the gum ache, 60% of respondents have suggested that they endure the ache or take a medicine to alleviate the pain, showing a lower understanding of early dental treatment. (4) Regarding the reason why they are unwilling to go to dentists, respondents have revealed the anxiety against pain, 50.4%, following by the difficulty of scheduling and unsatisfied services. (5) 47.2% of respondents have brushed their teeth 3 times everyday, following by those who have done it 2 times a day and those one a day. Regarding how to brush the teeth, most of respondents have brushed their teeth in the upper, lower, and the both side, 61.4%. The younger respondents and those who think they are in good dental health have tended to brush their teeth up and down. (6) Regarding the cause of the gum disease, 67.7% of respondents have thought that it is caused by poor dental hygiene, following by natural occurrence due to age, hereditary nature, and physical predisposition. (7) 67.7% of respondents have experienced dental scaling, while 32.3% of them have had no experience in it. 53.5% of workers have thought that scaling may not be recommended since they have the teeth scaled periodically once they had dental scaling, a higher rate than 46.5% who think scaling is good for the gum health.

  • PDF