• 제목/요약/키워드: Lower Active-bridge

검색결과 20건 처리시간 0.02초

Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법 (A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter)

  • 이준영;최현준;김주용;정지훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

현장 풍속 특성을 반영한 콘크리트 사장교의 버페팅 응답 (Buffeting Responses of Concrete Cable-stayed Bridge Considering Turbulent Characteristics of Bridge Site)

  • 김성호;임성순;권순덕
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.97-104
    • /
    • 2011
  • 본 연구에서는 교량 현장에서 계측한 풍속 스펙트럼을 풍동에서 구현하고, 콘크리트 사장교를 대상으로 공력 어드미턴스함수를 측정하였다. 그리고 현장 측정한 난류 특성을 바탕으로 콘크리트 사장교의 3차원 버페팅 해석을 수행하였다. 본 연구의 결과를 보면 적절히 공력 어드미턴스함수를 고려할 경우에 고려하지 않은 경우보다 버페팅 응답이 절반 가까이 줄어드는 것으로 나타났다. 그리고 격자난류를 사용할 경우에 저주파 영역에서 공력 어드미턴스 함수가 낮아서 풍하중을 과소평가할 가능성이 있는 것으로 나타났다. 공력 어드미턴스 함수가 버페팅 응답에 미치는 영향이 상당하므로 향후 교량의 버페팅 해석시 플러터계수나 능동난류로부터 추출한 공력 어드미턴스 함수를 사용할 것을 추천한다.

Effect of Trunk Inclination Angles on Trunk Muscle Activity and Subjective Difficulties During Supine Bridge Exercise with a Suspension Device

  • Kim, Jwa-Jun;Park, Se-Yeon
    • PNF and Movement
    • /
    • 제18권3호
    • /
    • pp.315-321
    • /
    • 2020
  • Purpose: Recent studies have indicated that applying different inclination angles and suspension devices could be a useful way of performing exercises that include the co-activation of the trunk muscles. Present study was to examine the influences of changes in the inclination angle during trunk muscle activity while engaging in a bridge exercise with a suspension device. Methods: 18 healthy, physically active male volunteers completed three trunk inclination angles (15°, 30°, and 45°) for bridge exercise variations. The surface electromyography responses of the rectus abdominis, internal oblique (IO), erector spinae (ES), and rectus femoris (RF), as well as the subjective difficulty (Borg RPE score), were investigated during these bridge exercises. Results: The bridge with a 45° inclination angle suspension significantly increased the muscular activities of the RA and RF and increased the Borg RPE scores (p<0.05). The bridge with a 15° suspension significantly elevated the ES activities when compared to the other conditions. Conclusion: The present study demonstrated that a higher inclination angle could not activate the overall trunk muscles during the bridge exercise. The RA and RF produced greater activation during the bridge exercise with the higher inclination angle. On the other hand, the activities of the erector spine were greater during the bridge exercise with the lower inclination angle. The present study suggests that applying a low trunk inclination angle for the supine bridge exercise is suitable for activating the erector spine muscles.

0 ~ 100 % 시비율을 갖는 새로운 모드 가변형 비대칭 풀 브리지 DC/DC 컨버터 (A New Mode Changable Asymmetric Full Bridge DC/DC Converter having 0 ~ 100 % Duty Ratio)

  • 신용생;노정욱;홍성수;한상규
    • 전력전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.103-110
    • /
    • 2010
  • 본 논문에서는 대용량급 전력변환회로를 대상으로, 기존 위상천이 풀 브리지 컨버터의 환류 전류 문제를 해결하기 위하여 새로운 모드 가변형 비대칭 풀 브리지 컨버터를 제안한다. 제안된 회로는 구동시비율 D에 따라 50% 이하에서는 비대칭 풀 브리지 컨버터로 동작하며, 50% 이상에서는 능동 클램프 풀 브리지 컨버터로 동작하게 된다. 따라서 제안된 회로는 정상상태시 약 50% 시비율로 동작되므로 기존 위상천이 풀 브리지 컨버터의 문제점인 환류전류를 제거 할 수 있으며, 이를 통하여 도통 손실을 줄일 수 있다. 또한, 넓은 부하범위에서 영전압 스위칭 동작이 가능하며, 출력 전류 리플도 매우 작은 장점이 있다. 특히 순간정전시 능동 클램프 컨버터로 동작 모드가 변하여 50~100% 시비율로 동작되므로 넓은 입력전압범위에 대해 대응이 가능하다. 본 논문에서는 제안된 회로의 동작원리 및 PSIM simulation을 수행하였으며, 1.2kW급 시작품을 제작하여 제안된 회로의 타당성을 검증하였다.

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

PSC 연속 거더교의 연속화부 거동에 관한 해석적 연구 (Analysis of the Behaviors of Continuous parts in Continuous PSC Girders Bridges)

  • 구민서;김훈희;정영도
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.404-411
    • /
    • 2002
  • The PSC 2-span-continuous-bridge by Up-Down Method on construction process is used for this research. It is measured the strain of lower-steel-plate at continuous section on the active range of negative moment at the stage of introducing compressive stress to bottom-plate and compared with results of structural analysis. On the basis of these results, it is confirmed the introduced compressive stress tか bottom-plate. The object of this research is presenting the degree of continuity at the stage of lifting up process.

  • PDF

역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터 (Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction)

  • 유병규;이성세;한상규;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

영전압 스위칭 하프브리지 컨버터와 포워드 컨버터의 효율 및 특성에 관한 연구 (A Study on Efficiency and Characteristic of Zero Voltage Switched Half-Bridge Converter and Forward Converter)

  • 서재광;김용;백수현;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.147-149
    • /
    • 1998
  • In this paper, zero voltage switched half bridge converter and an active-clamped, zero voltage switched forward converter equipped with self-driven synchronous rectifier is designed and investigated for high efficiency BC-DC converter. A synchronous rectifier is has a lower conduction power loss than shottky diode rectifier. The purpose of this paper is to investigate the effect of parasitic inductance in a synchronous rectifier of DC-DC converters and examine overall efficiency of zero voltage switched DC-DC converters.

  • PDF

Level Number Effect on Performance of a Novel Series Active Power Filter Based on Multilevel Inverter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.711-721
    • /
    • 2018
  • This paper presents a single-phase asymmetric half-bridge cascaded multilevel inverter based series active power filter (SAPF) for harmonic voltage compensation. The effect of level number on performance of the proposed SAPF is examined in terms of total harmonic distortion (THD) and system efficiency. Besides, the relationship between the level number and the number of switching device are compared with the other multilevel inverter topologies used in APF applications. The paper is also aimed to demonstrate the capability of the SAPF for compensating harmonic voltages alone, without using a passive power filter (PPF). To obtain the required output voltage, a new switching algorithm is developed. The proposed SAPF with levels of 7, 15 and 31 is used in both simulation and experimental studies and the harmonic voltages of the load connected to the point of common coupling (PCC) is compensated under two different loading conditions. Furthermore, very high system efficiency values such as 98.74% and 96.84% are measured in the experimental studies and all THD values are brought into compliance with the IEEE-519 Standard. As a result, by increasing the level number of the inverter, lower THD values can be obtained even under high harmonic distortion levels while system efficiency almost remains the same.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.