• 제목/요약/키워드: Low-temperature difference thermal energy

검색결과 61건 처리시간 0.027초

대구지역의 하절기 장.단파복사 관측 (Observation of Long and Short Wave Radiation During Summer Season in Daegu Area)

  • 오호엽;최동호;이부용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.134-139
    • /
    • 2012
  • This study observed downward long and short-wave radiant environment with selecting 4 areas which have different height in downtown and 1 suburban area to figure out the characteristic of radiant environment in each altitude. The purpose of this study is to collect the preliminary data for interpreting urban thermal environment in summer season by analyzing thermal characteristic of atmosphere in the upper of downtown. The results of this study are as follows. 1) The higher altitude has the lower temperature, and temperature difference was more huge in day time than night time. 2) The short wave radiation according to altitude was higher as altitude was high. 3) Generally, the higher altitude has the lower air temperature, and also the higher altitude has the lower downward long wave radiation by the atmospheric radiation. 4) The ratio short wave radiation of long wave radiation was lower as altitude was high. And the urbanization effect was higher as the ratio was low.

  • PDF

R32를 이용한 100kW급 해양온도차발전용 반경류터빈의 설계 (Design of a 100kW-class radial inflow turbine for ocean thermal energy conversion using R32)

  • 김도엽;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1101-1105
    • /
    • 2014
  • 해양온도차발전은 해양의 따뜻한 표층수와 차가운 심층수의 온도차를 발전에 이용하는 전도유망한 기술이다. 지속가능한 온도차를 이용하여 온실가스감축기술로서 활용할 수 있다는 장점을 가지는 반면, 시스템의 효율이 낮다는 단점을 가진다. 해양온도차발전의 낮은 시스템 효율을 개선하기 위해서는 성능이 우수한 터빈의 설계 및 개발기술의 확보가 필요하다. 이에 따라 본 연구에서는 R32를 이용한 100kW급 해양온도차발전용 반경류터빈을 설계하였으며, CFD 해석을 통해 설계한 터빈의 성능을 검증하였다. CFD 해석결과를 참고하여 설계한 반경류터빈의 형상을 수정하였으며 이러한 과정을 반복하여 설계요구조건에 적합한 해양온도차발전용 반경류터빈의 최종 형상을 도출하였다.

Study of Magnetic Field Shielded Sputtering Process as a Room Temperature High Quality ITO Thin Film Deposition Process

  • Lee, Jun-Young;Jang, Yun-Sung;Lee, You-Jong;Hong, Mun-Pyo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.288-289
    • /
    • 2011
  • Indium Tin Oxide (ITO) is a typical highly Transparent Conductive Oxide (TCO) currently used as a transparent electrode material. Most widely used deposition method is the sputtering process for ITO film deposition because it has a high deposition rate, allows accurate control of the film thickness and easy deposition process and high electrical/optical properties. However, to apply high quality ITO thin film in a flexible microelectronic device using a plastic substrate, conventional DC magnetron sputtering (DMS) processed ITO thin film is not suitable because it needs a high temperature thermal annealing process to obtain high optical transmittance and low resistivity, while the generally plastic substrates has low glass transition temperatures. In the room temperature sputtering process, the electrical property degradation of ITO thin film is caused by negative oxygen ions effect. This high energy negative oxygen ions(about over 100eV) can be critical physical bombardment damages against the formation of the ITO thin film, and this damage does not recover in the room temperature process that does not offer thermal annealing. Hence new ITO deposition process that can provide the high electrical/optical properties of the ITO film at room temperature is needed. To solve these limitations we develop the Magnetic Field Shielded Sputtering (MFSS) system. The MFSS is based on DMS and it has the plasma limiter, which compose the permanent magnet array (Fig.1). During the ITO thin film deposition in the MFSS process, the electrons in the plasma are trapped by the magnetic field at the plasma limiters. The plasma limiter, which has a negative potential in the MFSS process, prevents to the damage by negative oxygen ions bombardment, and increases the heat(-) up effect by the Ar ions in the bulk plasma. Fig. 2. shows the electrical properties of the MFSS ITO thin film and DMS ITO thin film at room temperature. With the increase of the sputtering pressure, the resistivity of DMS ITO increases. On the other hand, the resistivity of the MFSS ITO slightly increases and becomes lower than that of the DMS ITO at all sputtering pressures. The lowest resistivity of the DMS ITO is $1.0{\times}10-3{\Omega}{\cdot}cm$ and that of the MFSS ITO is $4.5{\times}10-4{\Omega}{\cdot}cm$. This resistivity difference is caused by the carrier mobility. The carrier mobility of the MFSS ITO is 40 $cm^2/V{\cdot}s$, which is significantly higher than that of the DMS ITO (10 $cm^2/V{\cdot}s$). The low resistivity and high carrier mobility of the MFSS ITO are due to the magnetic field shielded effect. In addition, although not shown in this paper, the roughness of the MFSS ITO thin film is lower than that of the DMS ITO thin film, and TEM, XRD and XPS analysis of the MFSS ITO show the nano-crystalline structure. As a result, the MFSS process can effectively prevent to the high energy negative oxygen ions bombardment and supply activation energies by accelerating Ar ions in the plasma; therefore, high quality ITO can be deposited at room temperature.

  • PDF

전기히터식 난방, 온풍난방시스템을 채용한 단동 플라스틱 하우스의 열부하 해석 및 난방성능 평가 (Evaluation of Heating Performance and Analysis of Heating Loads in Single Span Plastic Greenhouses with an Electrical or Hot-Air Heating)

  • 허종철;임종환;서효덕;최동호
    • 생물환경조절학회지
    • /
    • 제8권2호
    • /
    • pp.136-146
    • /
    • 1999
  • 본 연구에서는 동절기 시설원예용 하우스의 열환경, 난방방식별 에너지 소비 특성, 하우스내 열이동 프로세스자 난방효율에 대해서 중점적으로 검토하였다. 동절기 하우스의 벽체, 지붕을 통해 손실되는 관류열량을 정량적으로 계산하므로서, 하우스의 단열계획 및 난방에너지 절약을 유도할 수 있는 기초데이터를 제시하였다. 난방방식별 실내외 온도차와 에너지 소비량과의 관계를 정량적으로 도출하므로서, 쾌적성, 경제성을 고려한 최적의 하우스 난방방식 선정과 난방기 운용의 효율화를 유도하기 위한 기초자료를 제시하였다 난방방식별 실내외 온도차와 에너지 소비량과의 관계로부터 도출된 결과는 심야전력 난방이 온풍난방에 비해 난방효율이 현저히 높은 것으로 나타났다. 덕트 주변의 수평 및 연직방향으로 다수의 열전대를 설치하여 온풍 난방시 덕트주변의 작물에 미칠 수 있는 고온피해 발생 가능성을 검토하였으나, 약 1$^{\circ}C$이내의 비교적 균일한 온도가 계측되므로서, 온풍에 의한 주변작물의 고온피해는 관측되지 않았다. 덕트 길이방향으로 일정간격마다 덕트내부에 열전대를 설치하여 덕트길이에 따른 온도하강 추이를 검토한 결과, 덕트 단위길이당 0.5~0.8$^{\circ}C$의 온도강하가 계측되었다.

  • PDF

초소형 바이너리 발전 플랜트를 위한 Neuro PID 제어 (Neuro PID Control for Ultra-Compact Binary Power Generation Plant)

  • 한건영
    • 한국정보통신학회논문지
    • /
    • 제25권11호
    • /
    • pp.1495-1504
    • /
    • 2021
  • 초소형 바이너리 발전 플랜트는 열원과 냉각원 사이의 저온도차 열에너지를 이용하여 열에너지를 전력으로 변환한다. 실제 발전환경에서 플랜트의 특성치는 환경 조건이나 관련 장비의 부식과 같은 부정적인 영향으로 인해 변동하고, 플랜트 특성치의 변동은 PID 파라미터가 고정된 종래의 PID 제어시스템에서 불안정한 터빈 출력으로 이어진다. 본 논문에서는 플랜트의 특성치 변동에 따라 PID 파라미터를 적응적으로 조정하는 신경망 기반의 Neuro PID 제어시스템을 제안한다. 초소형 바이너리 발전 플랜트의 동작점 근방에서 동특성을 나타내는 이산시간 전달함수 모델을 도출하고, 제안된 제어시스템의 설계 전략을 기술한다. 제안된 Neuro PID 제어시스템을 종래의 PID 제어시스템과 비교하고, 시뮬레이션 결과를 통해 그 유효성을 보인다.

벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구 (An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater)

  • 백남춘;김성범;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

여과수열원 히트펌프를 이용한 온실난방기술 개발 (Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;강연구;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

콘크리트 포장에서 발생하는 온도피해 저감에 관한 연구 (A Study on the Reduction of Temperature Damage in Concrete Pavement)

  • 김재돈;장일영
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.305-312
    • /
    • 2023
  • 연구목적: 본 연구에서는 콘크리트 포장의 온도피해를 줄이기 위해 상변화에너지가 큰 PCM을 콘크리트에 혼입하고 이에 따른 성능테스트를 진행하였다. 연구방법:저온 및 고온에 대한 온도피해를 감소시키기 위해 4.5℃와 44℃의 상변화 온도를 가지는 캡슐형 PCM을 10%, 30%, 50% 치환하여 콘크리트에 혼입하였으며 열전대와 변온챔버를 활용하여 열성능 실험과 압축강도 실험을 진행하였다. 연구결과: 열성능 실험 결과 PCM의 혼입은 최대 25%이상의 온도저항성을 향상시키는 것으로 나타났으며 다량 치환시 높은 비열로 모든 온도에서 열저항성을 높이는 것으로 나타났다. 압축강도 실험 결과 30%이상의 치환은 압축강도를 저하시키는 결과를 나타냈으며 PCM의 상변화온도를 기준으로 큰 강도차이를 나타냈다. 결론: PCM의 혼입은 콘크리트의 열성능을 증가시키는 것으로 나타냈으며 PCM의 상변화온도 부근에서 가장 큰 열성능 증가폭을 나타냈다. 또한 가장 높은 치환율인 50% 치환에서 10%~20%의 작은 강도저하가 발생하였으므로 사용성에 큰 문제가 없을 것으로 판단되며 열성능 향상을 위해 추가적인 PCM 투입이 가능할 것으로 판단된다.

바이오디젤 혼합물의 함량변화에 따른 열적 특성에 대한 실험적인 연구 (Experimental Study on the Thermal Characteristics According to the Content Change of Biodiesel Mixture)

  • 김주석;고재선
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.532-544
    • /
    • 2023
  • 연구목적: 신규로 사용되는 바이오연료를 기존 연료와 혼합하여 사용하는 경우 발생하는 위험성과 물성 변화를 열분석 방법(DSC, TGA)을 사용하여 화학 화재의 원인물질의 위험성을 확인하고, 평가할 방법과 그에 따른 물질의 위험성 관련 데이터를 확보함으로써 화재 원인 감식과 감정에 활용하기 위함이다. 연구방법: 본 실험에 사용된 연구 방법으로는 시차주사열량계(DSC : Differential Scanning Calorimeter)에 의하여 피크의 위치, 모양, 개수, 피크의 면적으로부터 열량 변화의 정량적인 정보를 통하여 열유속 차이(Difference in heat flux)를 측정하였고, 열중량분석(TGA : Analyzer)을 시행함으로써 특정한 온도에서 분해열 등에 의해 발생한 무게 변화를 연속적으로 측정하였다. 연구결과: 먼저 열 유속의 그래프에서 물질의 끓는점과 물질이 가지고 있는 고유 특성치 또는 분해에 필요한 에너지를 확인할 수 있다. 둘째 바이오디젤의 함량이 증가할수록 많은 피크를 확인 할 수 있었다. 셋째 비점이 낮은 물질들이 함유하고 있다는 것을 분석 결과로 확인할 수 있었다. 결론: 현재 새로운 에너지원으로 사용되고 있는 바이오디젤의 위험성을 다양한 물리·화학적 분석기법(DSC+TGA)을 통하여 사용함으로써 물질의 물적 위험성을 평가할 수 있음을 보여주었다. 아울러 본 연구의 시험방법별 차이의 비교와 실험에 대한 노하우를 축적하고 활용한다면 향후 위험물의 물성 연구와 물질 위험성 평가 연구에 있어 도움이 되리라 기대한다.

저온 준안정상 $ZrO_2$의 안정화 (Stabilization of Low-Temperature Metastable Phase of $ZrO_2$)

  • 오영제;정형진;이희수
    • 한국세라믹학회지
    • /
    • 제27권5호
    • /
    • pp.613-618
    • /
    • 1990
  • The pure and 6mol% MgO-doped ZrO2 powders were prepared by hot petroleum drying method. The power characterization of homogeneous fine powder was indentified by the method of thermal analysis, BET and electron microscope. The transformation, content of t-ZrO2, crystallite size and apparent strain were measured by X-ray diffraction technique. The prepared powders were transformed in order of amorphouslongrightarrowmetastable cubic ZrO2longrightarrowmetastable tetragonal ZrO2longrightarrowstable monoclinic ZrO2 by a adequate heat treatment. The stabilization of metastable phase can be discussed in terms of energetial concept ; the difference of surface energy and internal strain in particle.

  • PDF