Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City (부산지역 대형병원 냉방장비의 용량설정 실태조사)

  • Lee, Ji-Weon;Chin, Kyung-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

Economic Feasibility of Various HVAC Systems for Commercial Building and Comparison of Energy Tariffs between Korea and USA (업무시설용 건물 적용 복합 지열원 공조시스템의 경제성 평가 및 한미 요금 비교)

  • Koh, Jae-Yoon;Park, Yool;Seo, Dong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.599-607
    • /
    • 2008
  • In this study, air conditioning systems include ground source heat pump (GSHP), are evaluated for economic feasibility. The building is modeled an air conditioned for 280kW scale. This analysis is compared with the energy tariff programs of Korea and USA. The objectives of this paper are to evaluate the cost-effectiveness of the GSHP and combined system using Life-Cycle Cost (LCC) analysis, and to carry out the sensitivity analysis of key parameters. The paper considered the cases including the base case of air source heat pump and the other two alternates for comparisons. The combined system is not only a cost-effective way to the low energy consumption but also a way to avoid a high initial investment. The variations of initial investment and energy rates give a significant effect on the total LCC and payback period.

A Study on the Interoperability Improvement of IFC Property Information for Energy Performance Assessment in the Early Design Phase (초기 설계단계 건물 에너지 성능평가를 위한 IFC 속성정보 호환성 향상에 관한 연구)

  • Kim, Inhan;Yoo, Hyunjae;Choi, Jungsik
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.6
    • /
    • pp.456-465
    • /
    • 2012
  • Nowadays, AEC industry tries to adopt BIM for low-carbon and eco-friendly building development. With increasing environment policies, many of global construction projects require the adoption of BIM for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some troubles in representation and property information in the process of Open BIM based energy performance assessment. To examine such troubles, this study focuses on differences between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. Two issues the study addresses are form representation and property information. The study figures out the different definition of IFC and IDF, and suggests the way of interoperability. The interoperability test of IFC for building energy performance assessment hope to develop of Open BIM based energy assessment.

Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions (창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구)

  • Choi, Min-Seo;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

A Study on the Improvement of G-SEED through Analysis of the Previous Studies - Based on Apartment Houses (선행연구 분석을 통한 녹색건축 인증제의 개선방향에 관한 연구 - 공동주택 부문을 중심으로)

  • Yun, Yo Sun;Ryu, Soo Hoon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.31-42
    • /
    • 2013
  • Green Standard for Energy and Environmental Design (G-SEED) is evaluates the eco-friendliness of the building as an abjective means. Study in green building is made actively, and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard. Therefore, this study analyzes the previous studies about G-SEED and checks the reflection of requirements. This study will be a reference of future revision of G-SEED. Score of items are divided into low and high score items. These items should be reflected appropriately in the standard through the score adjustment. Some requirements proposed in previous studies was reflected, while substantial requirements was not reflected. Proposed improvement requirements are classed as to establish specific standards, strengthen standards, propose a new evaluation method to existing items, and add new items.

Review of New Technologies' Energy Conservation Rate in High-Performance Buildings (High-Performance Buildings 구현을 위한 신기술 연구 동향 및 에너지 절감 효과 평가)

  • Kim, Chul-Ho;Yang, Ja-Kang;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy performance by applying new technologies for passive and active control. Method: We selected new technologies for passive and active control which are based on formal study by analyzing technology applied to the High-Performance Buildings in various countries. Also, we analyzed energy saving potential for each technologies by breakdown the result of the energy saving rates in detail. Result: For the wall and roof insulating methods, preceding studies showed that up to 21% energy could be saved by improving roof insulation and applying proper outside insulation compared to non-insulation. For the windows and glazing system, preceding studies showed that Low-E glazing system could save up to 11% energy compared to single glazing system. Studies about solar and daylighting controls revealed that effective daylighting dimming control could save 13% of energy compared to uncontrolled situation. Studies on DOAS (Dedicated Outdoor Air System) showed that about 23% energy could be saved compared to standard VAV system. Studies on the active chilled beam showed that about 25% energy could be saved compared to standard VAV system and studies of applying UFAD (Under Floor Air Distribution) could consume 31% less energy than applying overhead system.

A Study of Microscopic Energy Simulation based on BIM - Illuminance & Energy Analysis of Illuminance Sensor Lighting (BIM 기반의 미시적 에너지 시뮬레이션에 관한 연구 -조도센서등의 조도 및 에너지 분석을 중심으로)

  • Baek, Ji-Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.384-390
    • /
    • 2019
  • The importance of architecture design focused on eco-friendly and low energy continues to grow. In addition, the energy conservation design is required from a micro-perspective. Energy simulations based on BIM have attracted recent attention because of the high efficiency. On the other hand, the parameters concerned with microscopic energy are not included in BIM data. This study examined the necessity of the sensor-light parameter using a simulation of illuminance sensor light. In this study, illuminance sensors were installed into the BIM data and the operating schedule data of sensor light were generated by an illuminance simulation. The schedule data was then inputted into the simulation application, and the reduction ratio of power consumption was verified by the simulation. According to research, the power consumption and thermal load decreased by more than 20 %. Therefore, it is necessary to supplement the sensor-light parameter into BIM data for microscopic energy conservation design. This study was not confined to checking whether sensor-light parameter is necessary or not, but to ascertaining the necessary of applying a microscopic factor to generate BIM data.

Development of control and monitoring board for building energy saving valve (빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발)

  • Oh, Jin-Seok;Kang, Young-Min;Jang, Jae-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.895-902
    • /
    • 2018
  • Energy consumption in buildings is close to 40% of the total national energy consumption in developed countries such as US and Japan, and Korea accounts for 24% of total energy consumption. In buildings, HVAC can't freely control the cooling flow rate according to the required calorie, so energy is not used efficiently. Therefore, by using the energy saving valve, the flow rate can be controlled by the required amount of heat and the energy can be saved. In this paper, we define basic conditions and develop control and monitoring boards for building energy saving valves based on PIC processor with low power and high cost-effectiveness. The designed board displays and transmits in real time information about two temperature values, flow values and calculated calories for temperature difference measurement. The developed board will be useful for real - time monitoring of the state of the valve in the future and development of the valve for the offshore.

A Study on Characteristics of the Spectrum of Building Materials : Based on Granite (건축 재료의 스펙트럼 특성에 관한 연구 : 화강석을 중심으로)

  • Cho, Su-Hyun;Kim, Won-Woo;Shin, In-Jung;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.150-155
    • /
    • 2011
  • It is a wide range of types of building materials. Depending on the flow of time for the increased interest in building appearance of quality new and different materials are being developed. In particular, the case of granite widely used as cladding, recently, China's low-cost stone disguised as a large number of local granite stone as the domestic industry has been a big hit. Therefore, the purpose of study is establishment of the database for granite building exterior materials. For that, the domestic granite and chinese granite are selected. The spectrums of these material are investigated and analyzed.

  • PDF

Application of Accelerated Carbonation Reaction for Low Alkalinity of Recycled Aggregate

  • Lee, Jong-Chan;Lee, Sae-Hyun;Yoon, Sang-Hyuck;Song, Tae-Hyeob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.515-522
    • /
    • 2011
  • As Construction and Demolition (C&D) debris increases every year, systems have been adopted to compel the use of recycled aggregate made from C&D debris, and the use of recycled aggregate in the construction field has increased. But environmental problems linked to the alkalinity of recycled aggregate have occurred, and a study on approaches to lower the alkalinity of recycled aggregate is needed. It was certified by this study that a large amount of recycled aggregate could be carbonated in the C&D debris midterm-treatment field. As a result, the density and the water absorption of recycled aggregate after carbonation reaction was improved, and pH of recycled aggregate was lowered from over 11 to 9.4. X-ray Diffraction (XRD), Scanning Electron Microscope (SEM), Energy Dispersive Spectroscopy (EDS), and Thermogravimetry/Differential Thermal Analysis (TG/DTA) methods also indicated the carbonation of recycled aggregate.