• Title/Summary/Keyword: Low-LF

Search Result 266, Processing Time 0.033 seconds

An Analysis of Relationship between Self-Reported Anxiety, Depressiveness and Parametors of Heart rate variability based on Photoplethysmography (불안 및 우울에 대한 주관적 설문평가 지표와 맥파 신호 기반의 심박변이도 요소들 간의 상관관계 분석)

  • Lee, Chung-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.345-354
    • /
    • 2012
  • The purpose of this study is finding alternative parameters of the HRV so as to minimize the subjective errors by STAI and BDI, could be have two types of significant correlation levels depending on normalized method. Particularly, the LF/HF presented as the quantitative physiological parameter that can reflect both state-anxiety and trait-anxiety.

  • PDF

The Change of Heart Rate Variability in Anxiety Disorder after Given Physical or Psychological Stress (불안장애 환자에서 육체적 및 정신적 스트레스 시 심박변이도의 변화)

  • Cho, Min-Kyung;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • Objectives: This study was designed to assess the change of heart rate variability (HRV) at resting, upright, and psychological stress in anxiety disorder patients. Methods: HRV was measured at resting, upright, and psychological stress states in 60 anxiety disorder patients. We used visual analogue scale (VAS) score to assess tension and stress severity. Beck depression inventory (BDI) and state trait anxiety inventories I and II (STAI-I and II) were used to assess depression and anxiety severity. Differences between HRV indices were evaluated using paired t-tests. Gender difference analysis was accomplished with ANCOVA. Results: SDNN (Standard deviation of normal RR intervals) and low frequency/high frequency (LF/HF) were significantly increased, while NN50, pNN50, and normalized HF (nHF) were significantly decreased in the upright position compared to resting state (p < 0.01). SDNN, root mean square of the differences of successive normal to normal intervals, and LF/HF were significantly increased, while nHF was significantly decreased in the psychological stress state compared to resting state (p < 0.01). SDNN, NN50, pNN50 were significantly lower in upright position compared to psychological stress and nVLF, nLF, nHF, and LF/HF showed no significant differences between them. Conclusion: The LF/HF ratio was significantly increased after both physical and psychological stress in anxiety disorder, but did not show a significant difference between these two stresses. Significant differences of SDNN, NN50, and pNN50 without any differences of nVLF, nLF, nHF, and LF/HF between two stresses might suggest that frequency domain analysis is more specific than time domain analysis.

A Study of the Characteristics of the HRV of the Girl Showing a Precocious Puberty (성조숙 증상을 보이는 여아들의 HRV의 특성 연구)

  • Yang, Seung-Jeong;Park, Kyung-Mi;Cho, Seong-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.10-22
    • /
    • 2016
  • Objectives: The aim of the study was to investigate the characteristics of the autonomic innervation of the heart in Precocious Puberty (PP) Girls.Methods: We studied 87 girls visiting Dongshin University Suncheon Oriental Medicine hospital from first Januarty 2013 to 31th December 2015. Among the 87 girls who were selected 14 people under the age of 8. The subjects were categorized in two groups, 2 PP girls and 12 healthy controls. We studied the difference of Heart rate variability (HRV) between two groups by Independent samples T-test using SPSS for windows (version 22.0).Results: The Standard deviation of all normal R-R intervals (SDNN), The spuare root of the sum of the spuare of difference between adjacent normal R-R intervals (RMS-SD) of PP group was non-significantly lower than non-PP group. Total power (TP), Very low frequency power (VLF), High frequency power (HF), Low frequency power (LF) of PP group was non-significantly lower than non-PP group, LF/HF ratio of PP group was significantly higher than non-PP group. Normalized high frequency power (HF norm) of PP group was non-significantly lower than non-PP group. Normalized low frequency power (LF norm) of PP was non-signficantly higher than non-PP group.Conclusion: The results suggest that imbalance of sympathetic and parasympathetic nervous system from girls of precocious puberty can be seen.

A Study on Oriental Medicine Diagnostic Application through Analysis of Heart Rate Variability in Polycystic Ovary Syndrome Females (PCOS 여성의 HRV 특성 분석을 통한 한의학적 진단 활용성에 관한 연구)

  • Lee, Mi-Joo;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Khung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.4
    • /
    • pp.155-163
    • /
    • 2010
  • Purpose: The aim of the study was to compare the characteristics of the autonomic innervation of the heart in polycystic ovary syndrome(PCOS) patients with regulary cycling controls. Methods: We studied 21 patients visiting $\bigcirc\bigcirc$hospital from 25th June 2009 to 25th June 2010. The subjects were categorized in two groups, 11 PCOS patients and 10 healthy regularly cycling controls. We studied the difference of Heart rate variability (HRV) between two groups by Independent samples T-test using SPSS for windows(version 17.0). Results: The Standard deviation of all normal R-R intervals (SDNN), The spuare root of the sum of the spuare of difference between adjacent normal R-R intervals (RMS-SD) of PCOS group was non-significantly lower than non-PCOS group. High frequency power (HF) and Normalized high frequency power (HF norm) of PCOS group was significantly higher than non-PCOS group. Normalized low frequency power (LF norm) of PCOS was signficantly lower than non-PCOS group. The results means increased sympathetic and decreased vagal modulation. Total power (TP), Very low frequency power (VLF) of PCOS group was non-significantly lower than non-PCOS group. Low frequency power (LF), LF/HF ratio of PCOS group was non-significantly higher than non-PCOS group. Conclusion: The results suggest that PCOS can be related to decreased activity of parasympathetic nervous system.

Characteristics of Low-frequency Ambient Seismic Noise in South Korea (국내 저주파수 무작위 지진잡음의 특성 연구)

  • Park, Iseul;Kim, Ki Young;Byu, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.67-75
    • /
    • 2016
  • To investigate spatial and temporal variations of low-frequency (${\leq}5Hz$) ambient seismic noise, we analyzed the noise data recorded for one whole year of 2014 at surface accelerometer stations in South Korea. After decomposed into low-frequency (LF; < 1 Hz) and high-frequency (HF; ${\geq}1Hz$) components, the root-mean-squared (RMS) amplitudes and power spectral densities (PSD) of the noise data were computed. The RMS amplitudes were larger on islands and near-shore stations, but also large RMS amplitudes were observed at inland stations in large cities only for HF components. The RMS amplitudes of HF components were larger in the daytime than at nighttime and during weekdays than on Sunday and holidays. This indicates the HF components are closely related to human activities. On the contrary, daily and weekly variations were not clear in the LF components while they showed seasonal variations with its maximum during the winter and a good correlation with significant wave height. Therefore, we interpret the mechanism of LF components is closely related to natural phenomena such as sea. The amplitude of LF components decreased as an exponential function of the distance to the center of typhoons. The exponential index of -0.76 suggested that ambient seismic noise included both surface and body waves. Peak frequencies of the PSD curves were near 0.34 Hz indicating the double frequency. No temporal variation in the peak frequency was clearly noticed.

Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

  • Kim, Dae Gun;Jung, James J;Cho, Kwang Hwan;Ryu, Mi Ryeong;Moon, Seong Kwon;Bae, Sun Hyun;Ahn, Jae Ouk;Jung, Jae Hong
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.250-257
    • /
    • 2016
  • The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, $^{\circ}$) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.

Change of Heart Rate Variability in Depressive Disorder after Physical or Psychological Stress (우울장애 환자에서 육체적 및 정신적 스트레스 시 심박변이도의 변화)

  • Lee, Jong-Hwa;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon;Jeon, Hong-Jun;Park, Doo-Heum
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • Objectives: This study was designed to assess the change of heart rate variability (HRV) at resting, upright, and psychological stress states in depressive disorder patients. Methods: HRV was measured at resting, upright, and psychological stress states in 62 depressive disorder patients. We used visual analogue scale (VAS) score to assess tension and stress severity. Beck depression inventory (BDI) and state trait anxiety inventories I and II (STAI-I and II) were used to assess depression and anxiety severity, respectively. Differences between HRV indices and VAS score were evaluated using paired t-tests. Gender difference analysis was conducted with ANCOVA. Results: SDNN (standard deviation of normal to normal intervals), LF/HF (low frequency/high frequency), and VLF (very low frequency) were significantly increased, while NN50 and pNN50 were significantly decreased in the upright position compared to resting state. SDNN, RMSSD (root mean square of the differences of successive normal to normal intervals), and VLF were significantly increased, while pNN50 was significantly decreased in the psychological stress state compared to resting state. SDNN, NN50, and pNN50 were significantly lower in an upright position compared to a state of psychological stress, and LF, HF, and LF/HF showed no significant differences Conclusion: The LF/HF ratio was significantly increased after physical stress in depressive disorder. However, the LF/HF ratio was not significantly increased after psychological stress, and the change in LF/HF ratio after physical stress and psychological stress did not significantly differ from each other. Significant increase in SDNN, NN50, and pNN50 in an upright posture compared to psychological stress suggests that depressive patients react more sensitively to physical stress than psychological stress.

Development of a Quadrivalent Combined DTaP-HepB Vaccine with a Low Toxicity and a Stable HBsAg Immunogenicity

  • Bae, Cheon-Soon;Park, Kwung-Nam;Ahn, Sang-Jeom;Kim, Jong-Su;Hur, Byung-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.5
    • /
    • pp.787-792
    • /
    • 2002
  • When developing a combined DTaP-HepB vaccine, toxicity and HBsAg immunogenicity are both important considerations. Thus, for a combined DTaP-HepB vaccine with a low toxicity, the effect of the DTaP content and $Al(OH)_3$, gel concentration on the vaccine toxicity was investigated. Within the range studied, the higher the concentrations, the higher the vaccine toxicity. The importance of the tetanus toxoid content in the combined DTaP-HepB vaccine was also revealed. A higher concentration of the tetanus toxoid was found to have a negative effect on the stability of the HBsAg immunogenicity in the combined vaccine. Accordingly, considering the factors affecting toxicity and HBsAg immunogenicity, a novel DTaP-HepB vaccine (30 Lf/ml of diphtheria toxoid, 5 Lf/ml of tetanus toxoid, 10 $\mu\textrm{g}$ PN/ml of acellular pertussis, 24 $\mu\textrm{g}$/ml of HBsAg, and 500 $\mu\textrm{g}$ Al/ml of $Al(OH)_3$ gel) was developed. It has a low toxicity and a stable HBsAg immunogenicity and also satisfies the potency criteria of K-FDA for a combined DTaP vaccine.

Optimal Control of Dynamic Positioned Vessel Using Kalman Filtering Techniques (칼만필터를 이용한 부유체운동의 최적제어)

  • Lee, Pan-Muk;Lee, Sang-Mu;Hong, Sa-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.37-45
    • /
    • 1988
  • A dynamically positioned vessel must be capable of maintaining a specified position and direction by controlling the thruster devices. The motions of a vessel are often assuned to tne sum of low frequency(LF)motions and high frequency(HF)motions. The former is mainly due to wind, current and second order wave forces, while the latter is mainly due to first order wave forces. In order to avoid the high frequency thruser modulation, the control system must include filters to estimate the low frequency motions from the measured motion signals, This paper presents a control system based on Kalman filtering technique and optimal control tyeory. Using the combined kalmam filter, LF motion estimates and HF ones are achieved from the motion measurement of the vessel. The estimated low frequency motions are used as inputs to the dynamic positioning system. The thruster modulation is minimized using the optimal control theory; Linear Quadratic Gaussian(LQG)controller. The performances of the Kalman filter and the dynamic positioned vessel are investigated by computer simulation.

  • PDF

Power Conditioning System using LLC Resonant Inverter with Two Resonant Tanks (두개의 공진탱크회로를 갖는 LLC 공진 인버터 적용 PCS)

  • Yoon, Kwang-Ho;Chung, Bong-Gun;Lee, Kwang-Ho;Kim, Joo-Hoon;Kim, Eun-Soo;Choi, Joon-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.477-486
    • /
    • 2010
  • Recently, Power Conditioning System (PCS) tends to become more compact, and tends to require higher efficiency, and higher power density with better performance. To meet these requirements, a novel topology consisted of LLC resonant inverter with two resonant tanks for low power losses and Low Frequency (LF) cyclo-converter for sine wave filtering is proposed. The operating schemes are analyzed and described. A 400W proto product is built, tested and verified the performances by connecting the 110Vac 60Hz utility line.