• 제목/요약/키워드: Low-Impedance

검색결과 1,115건 처리시간 0.032초

병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석 (An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel)

  • 이복희;조성철;성창훈
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

Autonomous hardware development for impedance-based structural health monitoring

  • Grisso, Benjamin L.;Inman, Daniel J.
    • Smart Structures and Systems
    • /
    • 제4권3호
    • /
    • pp.305-318
    • /
    • 2008
  • The development of a digital signal processor based prototype is described in relation to continuing efforts for realizing a fully self-contained active sensor system utilizing impedance-based structural health monitoring. The impedance method utilizes a piezoelectric material bonded to the structure under observation to act as both an actuator and sensor. By monitoring the electrical impedance of the piezoelectric material, insights into the health of the structured can be inferred. The active sensing system detailed in this paper interrogates a structure utilizing a self-sensing actuator and a low cost impedance method. Here, all the data processing, storage, and analysis is performed at the sensor location. A wireless transmitter is used to communicate the current status of the structure. With this new low cost, field deployable impedance analyzer, reliance on traditional expensive, bulky, and power consuming impedance analyzers is no longer necessary. A complete power analysis of the prototype is performed to determine the validity of power harvesting being utilized for self-containment of the hardware. Experimental validation of the prototype on a representative structure is also performed and compared to traditional methods of damage detection.

해양 IT 소자에의 응용을 위한 RFIC/MMIC용 초소형 저임피던스 윌킨슨 전력분배기 설계 (Highly Miniaturized and Low impedance Wilkinson Power Divider on RFIC/MMIC for application to IT components of Ocean Engineering)

  • 김충열;윤영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.412-416
    • /
    • 2005
  • In this paper we propose low-impedance and miniaturized a wilkinson power divider on MMIC passive component which was fabricated by a novel microstrip line structure employing periodically perforated ground metal (PPGM). The novel microstrip line structure showed much lower impedance and shorter guided-wavelength than conventional one. Using the novel microstrip line with periodically perforated ground metal, a miniaturized 17 ${\Omega}$ power divider was fabricated. The line width of the power divider was 20 ${\mu}m$, and the size of it was 0.110 $mm^2$, which is 21 % of conventional one. The power divider exhibited good RF performances from 10 to 20 GHz.

  • PDF

Characterization of In-Situ Film Thickness and Chamber Condition of Low-K PECVD Process with Impedance Analysis

  • Kim, Dae Kyoung;Jang, Hae-Gyu;Kim, Yong-Tae;Kim, Hoon-Bae;Chae, Hee-Yeop
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.461-461
    • /
    • 2010
  • For a low dielectric constant inter-metal dielectric application, the low-k SiCOH film with a dielectric constant of 2.8-3.2 has been deposited by plasma-enhanced chemical vapor deposition with decamethylcyclopentasiloxane, cyclohexane, and helium which is carrier gas. In this work, we investigated chemical deposition rate, dielectric constant, characterization of plasma polymer films according to temperature(25C-200C) of substrate and change of component concentration. We measured impedance by using V-I prove during process. From experimental result, deposition rate decrease with increasing temperature. Through real time impedance analysis of chamber, we find corelation between film thickness and impedance by assuming equivalent circuit.

  • PDF

Literature Review on Recent Magnetocardiography and Impedance-Magnetocardiography Technologies

  • Kandori, A.;Miyashita, T.;Ogata, K.;Seki, Y.;Suzuki, D.;Tsukamoto, A.;Saito, K.;Yokosawa, K.;Tsukada, K.;Yamada, Satsuki;Watanabe, Shigeyuki;Horigome, Hitoshi;Yamaguchi, Iwao
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2006
  • We have developed magnetocardiography(MCG) and impedance magnetocardiography(I-MCG) for detecting heart disease by using dc-SQUID technology. The MCG system, using low-Tc SQUID, is being applied commercially for diagnosing heart disease. Using the low-Tc MCG system, many clinical studies on detection of abnormality have been performed. Furthermore, we have developed a portable MCG system using high-Tc SQUID. For detecting changes in kinetic impedance in the heart, an I-MCG system has been demonstrated. The I-MCG system could detect the mechanical movement of the heart. In this report, we review current clinical applications of magnetocardiography and impedance magnetocardiography.

  • PDF

EMTP를 이용한 매설지선의 규약접지임피던스 해석 (Analysis for the conventional impedance of counterpoise using EMTP)

  • 김종호;조정현;백영환;이강수;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2009
  • When the lightning currents flow through the ground electrode, the grounding system should be evaluated by the grounding impedance rather than the ground resistance because a grounding system shows the transient impedance characteristic by the inductance of the ground electrode and the capacitance of the soil. The ratio of the peak values of electric potential and currents is the conventional impedance that shows the transient characteristic about impulse currents of the grounding system in a roundabout way. The grounding system having low conventional impedance is a fine grounding system with low electric potential when the lightning currents flow. In this paper the conventional impedance of the counterpoise is calculated by using the distributed parameter circuit model and embodied the distributed parameter circuit model by using the EMTP program The adequacy of the distributed parameter model is examined by comparing the simulated and the measured results. The conventional impedance of the counterpoise is analyzed for first short stroke and subsequent short stroke currents.

  • PDF

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구 (Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC))

  • 박영진;김관호
    • 대한전자공학회논문지TC
    • /
    • 제41권8호
    • /
    • pp.93-97
    • /
    • 2004
  • 전력선 통신의 매체인 전력선은 60Hz 전력 공급을 위해 설계되었기 때문에 고속 전력선 통신을 위한 1MHz∼30MHz 대역에서는 전력선은 전기적으로 많은 다른 특징을 갖는다. 따라서 고속 전력선 통신을 위해서는 전력선의 고주파 특성-감쇄 지연, 임피던스-등이 자세하게 분석되고 연구되어야 한다. 본 논문에서는 고속 전력선 통신용 1MHz∼30MHz 주파수 대역 옥내저압 전력선 (220V) 임피던스를 측정하였다. 벡터 회로망 분석기와 저압 전력선 결합 장치(coupling unit)를 이용하여 임피던스를 측정하였다. 결합 장치를 T형 등가회로로 바꾸어, 전체 회로에서 얻은 산란계수를 이용하여 저압 전력선 임피던스를 구했다. 제안된 방법으로 표준 한국형 저층 연립 아파트에 대한 임피던스를 측정하고, 그 특성을 분석하였다. 또한 임피던스 정합을 위하여 평균 임피던스를 구하였고, 측정결과 평균 임피던스는 약 100Ω이었다.

배전계통에 사용되는 봉형 접지전극의 접지 특성 분석 (Grounding Characteristics Analysis of the Rod-Type Grounding Electrodes used for Electric Distribution Systems)

  • 김경철;정지원
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.49-56
    • /
    • 2011
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the copper and concrete rod grounding electrodes. An equivalent transfer function model of the ground impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing the conventional grounding impedance.

스피커의 전기적 임피던스를 이용한 시료의 음향임피던스와 흡음계수 도출 기법 (Method of deriving the acoustic impedance and sound absorption coefficient of materials by manipulating electrical impedance of a loudspeaker)

  • 두세진
    • 한국음향학회지
    • /
    • 제40권3호
    • /
    • pp.254-260
    • /
    • 2021
  • 시료의 흡음률 측정을 위해서는 비용이 많이 드는 잔향실 혹은 저주파수에서의 측정에 한계가 있는 임피던스 튜브를 사용한다. 본 논문에서는 마이크로폰을 사용하지 않고 단지 스피커 임피던스와 이로부터 도출된 Thiele/Small 변수만을 사용하여 시료의 음향임피던스와 흡음률을 구하는 기법을 제안하였다. 스피커의 등가회로를 이용하여 이 방법의 이론을 설명하였으며, 시료의 측정을 통하여 본 방법의 유효성을 증명하였다. 본 방법은 기존에 신뢰하기 어려웠던 저주파 대역에서의 흡음률을 매우 쉽게 측정할 수 있음을 확인하였다. 본 방법의 장점과 제한사항, 그리고 응용 분야에 대해서 검토하였다.