• 제목/요약/키워드: Low voltage operation

검색결과 1,030건 처리시간 0.028초

전동기 친화형 출력필터를 이용한 영구자석 동기전동기의 센서리스 구동 성능 향상 (Performance Improvement of Sensorless PMSM Drives using Motor Friendly Output Filter)

  • 부한영;백승훈;한상훈;조영훈
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.329-332
    • /
    • 2020
  • A back-electromotive force (back-EMF) estimator for a permanent magnet synchronous motor (PMSM) uses the three-phase voltage references of a current controller to estimate rotor position. However, owing to voltage drops caused by the nonlinear characteristics of switches and passive components, the actual voltage in the motor and the three-phase voltage reference may not match. This study proposes a sensorless control method using a sine-wave output filter applied between the motor drive system and PMSM. The precise voltage in the motor can be measured with the sine-wave output filter and applied to the input of the estimator. Moreover, given that the voltage in the motor can be measured precisely at extremely low speeds, the stable operation range of the back-EMF estimator can be secured. Experimental results show that the proposed sensorless control method has stable operation at extremely low speeds compared with conventional sensorless control.

적정 전압 여자를 적용한 이중 정격 SRM의 가변속 운전 (Variable speed operation of SRM with dual rating using proper voltage excitation)

  • 안영주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.348-352
    • /
    • 2016
  • 본 논문은 적정 전압 여자를 적용한 스위치드 릴럭턴스 전동기의 효율 개선에 대하여 기술한다. 세탁기와 같이 적용 속도에 큰 차이가 있는 부하의 경우 일정한 직류링크전압으로는 효율 개선에 어려움이 있다. 저속운전영역에서 과도한 직류전압의 영향을 줄이기 위해 보통 사용되고 있는 구동회로내의 다이오드 정류기 대신 SCR을 사용한 AC-DC 컨버터가 SRM 드라이버에 포함된다. AC-DC 컨버터는 저속에 알맞은 적정한 여자전압을 공급한다. 실험결과를 통하여 저속영역에서 효율이 개선됨을 확인하였다.

배전계통에서의 분산전원 도입운용 관리방법 : LDC 운전을 하지 않을 경우 (A Control Method of Distributed Generation System Which is Connected to Power Distribution System : Without LDC Operation)

  • 정원재;김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.231-233
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers. So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper computes permissible operation limit of DGS when the DGS is connected to power distribution system using fixed tap(without LDC operation). For this simulation, KEPCO distribution system is used.

  • PDF

저전압/저전력 고성능 배럴 쉬프터의 설계 (Design of Low Voltage/Low Power High performance Barrel Shifter)

  • 조훈식;손일헌
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1093-1096
    • /
    • 1998
  • The architecture and circuit design of low voltage, high performance barrel shifter is proposed in this paper. The proposed architecture consists of two arrays for byte and bit rotate/shift to perform 32-bit operation and is preferred for even bigger data length as it can be adapted for 64-bit extention with no increase of number of stages. NORA logic structure was used for circuit implementation to achieve the best performance in terms of speed, power and area. The complicated cloking control has been resolved with the ingenious design of clock dirver. The circuit simulation results in 3.05ns delay, 9.37㎽ power consumption at 1V, 160MHz operation when its implemented in low power $0.5\mu\textrm{m}$ CMOS technology.

  • PDF

A High Voltage, High Side Current Sensing Boost Converter

  • Choi, Moonho;Kim, Jaewoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.36-37
    • /
    • 2013
  • This paper presents high voltage operation sensing boost converter with high side current. Proposed topology has three functions which are high voltage driving, high side current sensing and low voltage boost controller. High voltage gate driving block provides LED dimming function and switch function such as a load switch of LED driver. To protect abnormal fault and burn out of LED bar, it is applied high side current sensing method with high voltage driver. This proposed configuration of boost converter shows the effectiveness capability to LED driver through measurement results.

  • PDF

Multi-bit Sigma-Delta Modulator for Low Distortion and High-Speed Operation

  • Kim, Yi-Gyeong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제29권6호
    • /
    • pp.835-837
    • /
    • 2007
  • A multi-bit sigma-delta modulator architecture is described for low-distortion performance and a high-speed operation. The proposed architecture uses both a delayed code and a delayed differential code of analog-to-digital converter in the feedback path, thereby suppressing signal components in the integrators and relaxing the timing requirement of the analog-to-digital converter and the scrambler logic. Implemented by a 0.13 ${\mu}m$ CMOS process, the sigma-delta modulator achieves high linearity. The measured spurious-free dynamic range is 89.1 dB for -6 dBFS input signal.

  • PDF

저압 AC회로의 MOV 적용방안 연구 (A Study on the Utilization of Metal Oxide Varistor for Low-Voltage AC Circuits)

  • 최효열;이원빈;강영석;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1822-1824
    • /
    • 1996
  • Damage and upset of control and communication equipment due to transient overvoltages which occur due primarily to internal switching surge and external lightning surge are an important problems in electromagnetic compatibility(EMC). In this paper, we analyzed operation characteristic of metal oxide varistor widely used low voltage AC line using the electromagnetic transients program(EMTP) and compare it with experimental results and also, we modeled combination generator producing $1.2/50{\mu}s$ open circuit voltage and $8/20{\mu}s$ short circuit current as a source which is critical in calculating operation characteristic. Simulation results showed that most of Transient energy consumes at MOV located in service entrance side than load side, and it showed similar to experimental results. Therefore, entrance side MOV should be selected more energy capacity than that of load side MOV.

  • PDF

A Novel Inter-Digital Tunable Capacitor for Low-Operation Voltage Applications

  • Lee, Young Chul
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.586-589
    • /
    • 2012
  • In this paper, a tunable capacitor like an interdigital one is presented for low-voltage applications. In order to reduce operation voltage by enhancing fringing electric fields, two finger-patterned electrodes are vertically separated by employing a multi-layer thin film dielectric of a para-/ferro-/para-electrics without spacing between electrodes. The proposed tunable capacitor was fabricated on a quartz wafer and its characteristics are analyzed in terms of effective capacitance and tunability with a function of applied voltages, compared to the conventional interdigital capacitor (IDC). At 8V and 2 GHz, the proposed tunable capacitor shows the tunability of 18 % that is 10.3 % higher than that of the compared one.

  • PDF

V/F 제어 고속 유도전동기의 전류 진동 억제 방법 (Suppression method for current oscillation of V/F controlled high speed induction motor)

  • 이진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.150-151
    • /
    • 2017
  • This paper deals with the suppression of subharmonic current oscillation of V/F controlled high speed induction motor drive in turbo blower applications. High speed induction motor has a relatively low stator impedance for high speed operation and therefore the dc link voltage ripple may result in subharmonic current oscillation at the steady state in high speed operation. This paper shows that the subharmonic oscillation is caused by the dc link voltage ripple and also proposes the suppression method, which generates the compensation voltage through the proportional current controller to reduce the subharmonic current oscillation. The simulation and experimental results show that the proposed suppression method reduces the subharmonic current oscillation to the acceptable low level in turbo blower applications.

  • PDF

Electrical Applications of OTFTs

  • Kim, Seong-Hyun;Koo, Jae-Bon;Lim, Sang-Chul;Ku, Chan-Hoi;Lee, Jung-Hun;Zyung, Tae-Hyoung
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.170-170
    • /
    • 2006
  • [ ${\pi}-conjugated$ ] organic and polymeric semiconductors are receiving considerable attention because of their suitability as an active layer for electronic devices. An organic inverter with a full swing and a high gain can be obtained through the good qualities of the transfer characteristics of organic thin-film transistors (OTFTs); for example, a low leakage current, a threshold voltage ($V_{th}$) close to 0 V, and a low sub-threshold swing. One of the most critical problems with traditional organic inverters is the high operating voltage, which is often greater than 20 V. The high operating voltage may result in not only high power consumption but also device instabilities such as hysteresis and a shift of $V_{th}$ during operation. In this paper, low-voltage and little-hysteresis pentacene OTFTs and inverters in conjunction with PEALD $Al_{2}O_{3}\;and\;ZrO_{2}$ as the gate dielectrics are demonstrated and the relationships between the transfer characteristics of OTFT and the voltage transfer characteristics (VTCs) of inverter are investigated.

  • PDF