• 제목/요약/키워드: Low head

검색결과 1,402건 처리시간 0.026초

Design of a Low Distortion Head-Mounted Display with Freeform Reflective Mirror Based on Two Ellipsoids Structure

  • Wang, Junhua;Liang, Yuechao;Xu, Min
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.234-238
    • /
    • 2016
  • A new method to design a low distortion, even relative illumination, optical see-through head-mounted display (HMD) with a freeform reflective mirror (FFRM) based on the two similar ellipsoids structure is proposed. The HMD we have realized has a simple structure which consists of two similar ellipsoid surfaces, an FFRM, a 7-piece co-axis relay lens, and an OLED. This structure can be applied to offset distortion, reach even relative illumination, and correct the off-axis aberrations. The HMD we finally have realized has a near 3% low distortion, a higher than 80% relative illumination, and a 40°×30° field of view (FOV).

Experimental Study on Adjustment of Inlet Nozzle Section to Flow Rate Variation for Darrieus-type Hydro-Turbine

  • Watanabe, Satoshi;Shimokawa, Kai;Furukawa, Akinori;Okuma, Kusuo;Matsushita, Daisuke
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권1호
    • /
    • pp.30-37
    • /
    • 2012
  • A two dimensional Darrieus-type turbine has been proposed for the hydropower utilization of extra-low head less than 2m. In a practical use of Darrieus-type hydro-turbine, head and flow rate may be varied temporally and seasonally. Considering that the cost advantage is required for the low head hydro turbine system, the Darrieus turbine should be operated with high efficiency in the wider range of flow rate possibly by using an additional device with simpler mechanism. In the present paper, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed to obtain the preferable inlet velocity in low flow rate conditions. Effects of resulting spanwise partial inlet flow are investigated. Finally, an effective modification of inlet nozzle height over flow rate variation is shown.

Experimental and Numerical Investigations on Performances of Darriues-type Hydro Turbine with Inlet Nozzle

  • Matsushita, Daisuke;Tanaka, Kei;Watanabe, Satoshi;OKuma, Kusuo;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권4호
    • /
    • pp.151-159
    • /
    • 2014
  • Low head hydropower is one of realistic renewable energies. The Darrieus-type hydro turbine with an inlet nozzle is available for such low head conditions because of its simple structure with easy maintenance. Experimental and numerical studies are carried out in order to examine the effects of gap distances between the runner pitch circle and two edges of inlet nozzle on turbine performances. By selecting narrower gaps of left and right edges, the performance could be improved. From the results of two dimensional numerical simulations, the relation between the performance and flow behaviors around the Darrieus blade are discussed to obtain the guideline of appropriate inlet nozzle design.

고화질 VCR용 복합 MIG HEAD (Composite MIG Head for High Definition VCRs)

  • 권상일
    • 한국자기학회지
    • /
    • 제6권1호
    • /
    • pp.7-14
    • /
    • 1996
  • 고밀도화, 광대역화하는 자기기록계의 요구에따라 복합 MIG head를 개발하였다. Head 동특성 측정기와 ME tape를 사용하여 기록 및 재생 특성을 SD VCR 포맷에 대해 검토한 결과, 기록시 20 MHz에서 포화가 발생되지 않았고, 재생시 우수한 상대효율의 주파수 의존성과 접동 잡음특성이 확보됨으로서 C/N 특성의 개선을 도모할 수 있었고 또한 ME tape에 대한 우수한 compatibility는 SD VCR 용 head로서의 적용을 유력하게 하고 있다.

  • PDF

전산유체역학 해석에 기반한 20kW급 도립형 횡류수차의 제작 및 성능 실증 (Fabrication and Performance Demonstration of the 20kW Class Inverted-type Cross-flow Turbine Based on Computational Fluid Dynamics Analysis)

  • 함상우;최지웅;정창호;김태윤;최상인;진근영;이정완;하호진
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.107-119
    • /
    • 2021
  • The cross-flow turbine is one of the most famous and widely used hydraulic power systems for a long time. The cross-flow turbine is especially popular in many countries and remote regions where off-grided because of its many benefits such as low cost, high efficiency at low head, simple structure, and easy maintenance. However, most modern turbines, including the cross-flow turbine, are unsuitable for the ultra-low head situation, known as less than 3m water head or zero head with over 0.5m/s flow velocity. In this study, we demonstrated a 20kW class inverted-type cross-flow turbine's performance. First, we reevaluated our previous studies and introduced how to design the inverted-type cross-flow turbine. Secondly, we fabricated the 20kW class inverted-type cross-flow turbine for the performance test. And then, we designed a testbed and installed the turbine system in the demonstration facility. In the end, we compare the demonstration with its previous CFD results. The comparing result shows that both CFD and real model fitted on guide vane angle at 10 degrees. At the demonstration, we achieved 42% turbine efficiency at runner speed 125 RPM.

추돌시 Head Restraints 시스템의 구속 효과와 인체 상해에 관한 연구 (A Study on Restraint Effects of Head Restraint Systems and Neck Injuries in Rear-End Crash)

  • 이창민
    • 대한인간공학회지
    • /
    • 제17권3호
    • /
    • pp.1-11
    • /
    • 1998
  • Focuses of this study are to investigate the usage status of head-restraint system(H/R) in usual driving and to simulate usage conditions of H/R at rear-end crashes. The usage of H/R was categorized into five classes according to the height and distance from occupant's head ; Large-$90^{\circ}$ H/R for enough height and short distance. Large-$70^{\circ}$ H/R for enough height and long distance. Small-$90^{\circ}$ H/R for low height and short distance. Small-$70^{\circ}$ H/R for low height and long distance. and No H/R. Then. these five conditions were tested to find out the degree of neck injuries by using a car-crash simulation package, DYNAMAN. Results from the investigation of H/R usage show that most of drivers(60%) have Small-$70^{\circ}$ H/R for low height and long distance. Results from the simulation performed at 15mph and 30mph show that: 1) at 15 mph, there is a possibility for neck injury in Small-$90^{\circ}$ H/R and Small-$70^{\circ}$ H/R. 2) at 30 mph. there is a high possibility of death in Small-$70^{\circ}$ H/R and Small-$90^{\circ}$ H/R.

  • PDF

Design and Analysis of A Pico Propeller Hydro Turbine Applied in Fish Farms using CFD and Experimental Method

  • Tran, Bao Ngoc;Kim, Jun-ho
    • 해양환경안전학회지
    • /
    • 제25권3호
    • /
    • pp.373-380
    • /
    • 2019
  • In this paper, a pico hydro turbine employing low head circulation water at fish farms is designed and evaluated. Due to the advantages of simple structures, small head requirements, and low-cost investment, the constant thickness propeller turbine is considered as a feasible solution. The design process based on the free vortex method is presented in full detail, and a 4-blade runner is built using BladeGen. The turbine performance is analyzed both numerically and via experimental methods. Despite slight differences, the results show similar trends between CFD simulations and experiments carried out on factory test-rigs in a wide range of working conditions. At the design flow rate, the turbine achieves the best efficiency of 70 %, generating 3.5 kW power when rotating at 420 rpm. The internal flow field, as well as the turbine's behavior, are investigated through the distribution of blade streamlines, pressure, and velocity around the runner. Moreover, the pressure coefficient on the blade surface at 3 span positions is plotted while the head loss for each simulation domain is calculated and displayed by charts.

흉쇄유돌근에서 기인한 Low-Grade Myofibroblastic Sarcoma 1예 (Low Grade Myofibroblastic Sarcoma of the Sternocleidomastoid Muscle)

  • 심남석;홍현준;송기재;최성은;서연석;이은정
    • 대한두경부종양학회지
    • /
    • 제30권1호
    • /
    • pp.23-27
    • /
    • 2014
  • Low-grade myofibroblastic sarcoma is a rare disorder of malignant soft tissue tumor and is usually occurred various regions that often manifests in the head and neck region. The most common clinical presentation of this entity is non-tender cervical lymphadenopathy. This disease usually presents high possibility of local recurrence and low possibility of distant metastasis. We report a rare case of low-grade myofibroblastic sarcoma occurring in the sternocleidomastoid muscle and invading to the mastoid tip. A 56-year-old male visited the clinic with a complaint of slowly growing postauricular mass for 6 months. Mass originating from sternomastoid muscle and invasion to mastoid tip was observed by imaging studies. Surgical complete excision with simple mastoidectomy was performed via modified facelift approach. The histopathologic findings revealed malignant spindle cell tumor with positive staining with smooth muscle actin. The patient has no recurrence for 2years without any complication.

Feasibility of Revision Cochlear Implant Surgery for Better Speech Comprehension

  • Hwang, Kyurin;Lee, Jae Yong;Oh, Hyeon Seok;Lee, Byung Don;Jung, Jinsei;Choi, Jae Young
    • Journal of Audiology & Otology
    • /
    • 제23권2호
    • /
    • pp.112-117
    • /
    • 2019
  • Background and Objectives: The purpose of this study was to evaluate the efficacy of revision cochlear implant (CI) surgery for better speech comprehension targeting patients with low satisfaction after first CI surgery. Subjects and Methods: Eight patients who could not upgrade speech processors because of an too early CI model and who wanted to change the whole system were included. After revision CI surgery, we compared speech comprehension before and after revision CI surgery. Categoies of Auditory Performance (CAP) score, vowel and consonant confusion test, Ling 6 sounds, word and sentence identification test were done. Results: The interval between surgeries ranged from eight years to 19 years. Same manufacturer's latest product was used for revision surgery in six cases of eight cases. Full insertion of electrode was possible in most of cases (seven of eight). CAP score (p-value=0.01), vowel confusion test (p-value=0.041), one syllable word identification test (p-value=0.026), two syllable identification test (p-value=0.028), sentence identification test (p-value=0.028) had significant improvement. Consonant confusion test (p-value=0.063), Ling 6 sound test (p-value=0.066) had improvement but it is not significant. Conclusions: Although there are some limitations of our study design, we could identify the effect of revision (upgrade) CI surgery indirectly. So we concluded that if patient complain low functional gain or low satisfaction after first CI surgery, revision (device upgrade) CI surgery is meaningful even if there is no device failure.

Feasibility of Revision Cochlear Implant Surgery for Better Speech Comprehension

  • Hwang, Kyurin;Lee, Jae Yong;Oh, Hyeon Seok;Lee, Byung Don;Jung, Jinsei;Choi, Jae Young
    • 대한청각학회지
    • /
    • 제23권2호
    • /
    • pp.112-117
    • /
    • 2019
  • Background and Objectives: The purpose of this study was to evaluate the efficacy of revision cochlear implant (CI) surgery for better speech comprehension targeting patients with low satisfaction after first CI surgery. Subjects and Methods: Eight patients who could not upgrade speech processors because of an too early CI model and who wanted to change the whole system were included. After revision CI surgery, we compared speech comprehension before and after revision CI surgery. Categoies of Auditory Performance (CAP) score, vowel and consonant confusion test, Ling 6 sounds, word and sentence identification test were done. Results: The interval between surgeries ranged from eight years to 19 years. Same manufacturer's latest product was used for revision surgery in six cases of eight cases. Full insertion of electrode was possible in most of cases (seven of eight). CAP score (p-value=0.01), vowel confusion test (p-value=0.041), one syllable word identification test (p-value=0.026), two syllable identification test (p-value=0.028), sentence identification test (p-value=0.028) had significant improvement. Consonant confusion test (p-value=0.063), Ling 6 sound test (p-value=0.066) had improvement but it is not significant. Conclusions: Although there are some limitations of our study design, we could identify the effect of revision (upgrade) CI surgery indirectly. So we concluded that if patient complain low functional gain or low satisfaction after first CI surgery, revision (device upgrade) CI surgery is meaningful even if there is no device failure.