연질 PE관을 이용한 여름딸기 부분냉방기술 개발 (Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe)

  • 문종필;강금춘;권진경;이수장;이종남
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

열화시간에 따른 폴리에틸렌 파이프의 기계적 물성 거동 (Mechanical Property Behaviors of Polyethylene Pipe due to Thermal-Degradation)

  • 원종일;최길영
    • 폴리머
    • /
    • 제33권5호
    • /
    • pp.446-451
    • /
    • 2009
  • 신뢰성 평가 시험법인 RS M 0042에 따라, 열화시간 경과에 따른 선형저밀도 폴리에틸렌 파이프의 신뢰성 평가를 수행하였다. 열화시간이 증가함에 따라, 인장강도는 250일 열화시점까지 비례적으로 증가하였고, 경도는 비교적 미소한 증가를 보였으며, 연신율은 점진적으로 감소하는 경향을 보였다. 이러한 결과는 열화시간이 증가함에 따른, 결정화도의 증가와 열산화에 의한 가교밀도의 증가, 사슬 전단 및 사슬 운동성의 감소 등에 기인한 것으로 판단된다. 장기정수압시험 결과는 초기의 연성파괴에서 차후 취성파괴로 전환되는 시점이 존재함을 확인하였다. 산화유도시간 측정은 선형저밀도폴리에틸렌 파이프의 열산화 정도를 관찰하기 위해 도입되었다. 측정 결과는 250일 이후 선형저밀도폴리에틸렌 파이프에 첨가된 산화방지제가 거의 고갈되었음을 보여준다. $100^{\circ}C$ 열화 조건에서 산화방지제의 잔존량을 계산할 수 있는 실험식을 열화시간의 함수로 표현하여 제안하였다. 적외선분광분석 결과는 열화된 선형저밀도폴리에틸렌 파이프 표면상에 카르보닐 및 하드록실 관능기가 증가하였음을 보여준다. 이는 선형저밀도폴리에틸렌 표면의 탄화수소 그룹의 산화가 국부적으로 발생하였음을 나타낸다.

폐폴리에틸렌 필름의 재활용에 관한 연구 (A Study on Recycling of Waste Polyethylene Film)

  • 이환광
    • 한국산학기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.182-188
    • /
    • 2008
  • 폐폴리에틸렌 필름을 재활용하기 위하여 폐폴리에틸렌과 비산재를 사용하여 콤파운드를 제조하였다. 실험에 사용한 고분자는 생활쓰레기에서 분리수거한 폴리에틸렌(PE)과 포장용 필름을 생산하는 공장에서 발생하는 스크랩에서 얻어지는 저밀도폴리에틸렌(LDPE)과 선형저밀도폴리에틸렌(LLDPE)이다. 폐폴리에틸렌의 물리적 성질을 개량시키기 위하여 화력발전소 굴뚝에서 포집한 석탄재와 생활쓰레기 소각로굴뚝에서 얻어지는 비산재를 사용하였다. 발전소 석탄재를 투입하면 재활용 LDPE와 LLDPE 콤파운드의 인장강도는 감소하고 굴곡모듈러스는 증가하였다. 역청탄재를 혼합한 경우에 비하여 무연탄재를 투입한 LLDPE 콤파운드의 인장강도와 굴곡강도가 약간 높았으며, 이는 무연탄재가 다소 많은 량의 미연소 탄소를 가지기 때문으로 사료된다. 생활쓰레기에서 얻어진 PE 단독에 소각로 비산재를 투입하면 인장강도와 굴곡강도가 모두 증가하였다. 이와 같은 소각로 비산재에 의한 상승효과는 생활쓰레기 PE에 포장용 필름 스크랩의 LDPE를 섞게 되면 Filler 입자가 LDPE의 결정화를 방해하기 때문에 상쇄되는 현상이 관찰되었다. 소각로 비산재를 혼합하여 생활쓰레기 PE를 재활용한 콤파운드는 하수관 등을 제조하는 원료로 사용이 가능하다. 본 연구결과를 폐플라스틱의 재활용에 적용시키면 폐기물처리 비용을 절감하고 환경보존과 자원절약에 기여할 수 있다.

실해역 환경에서 생물부착에 관한 기초실험 연구 (Preliminary Experimental Study on Biofouling in Real Sea Environment)

  • 정동호;김아리;문덕수;이승원;김현주;함윤호
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.39-43
    • /
    • 2009
  • A flow and low temperature of deep seawater the biofouling properties in a seawater environment of different materials, such as a steel pipe, polyethylene pipe, and nylon net, used for ocean industries. Experiments in a real sea environment were performed to grasp the quantitative and qualitative biofouling from diatoms attached to materials by measuring the Chlorophyll-a density. Experimental samples were placed under five types of ocean environmental conditions and analyzed every month for five months. It is shown that the biofouling by diatoms was strongly affected by the seawater temperature for all of the experimental samples. It was found that diatoms mainly adhered to the nylon net, while crustaceans prefer polyethylene, under a high temperature condition. It is believed that the biofouling properties are strongly related to the surface roughness of a material. The biofouling under the low temperature condition of deep seawater was rare and stable for the experimental periods. The inside of a pipe conveying deep seawater can be presumed to remain clear without biofouling on the condition of a flow and low temperature of deep seawater.

온수배관을 이용한 시설딸기 부분난방기술 개발 (Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe)

  • 문종필;강금춘;권진경;백이;이태석;오성식;남명현
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

고설 딸기 관부 난방시스템의 에너지 절감 효과 (Energy Saving Effect for High Bed Strawberry Using a Crown Heating System)

  • 문종필;박석호;권진경;강연구;이재한;김형권
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.420-428
    • /
    • 2019
  • 본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관(백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 $20{\sim}23^{\circ}C$, 관부 온도를 $13{\sim}15^{\circ}C$로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 $20{\sim}23^{\circ}C$의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 $4^{\circ}C$ + 관부난방(처리 1), 공간 난방 $8^{\circ}C$ (대조구), 공간 난방 $6^{\circ}C$ + 관부난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 $8^{\circ}C$(대조구)의 경우 1,320L(100%), 공간난방 $4^{\circ}C$ + 관부난방의 경우 928L(70.3%), 공간난방 $6^{\circ}C$ + 관부난방의 경우 1,161L (88%)로 계측되었다. 공간난방 $4^{\circ}C$ + 관부난방(처리 1) 및 공간난방 $6^{\circ}C$ + 관부난방(처리 2)은 $8^{\circ}C$ 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.

Investigation on the thermal butt fusion performance of the buried high density polyethylene piping in nuclear power plant

  • Kim, Jong-Sung;Oh, Young-Jin;Choi, Sun-Woong;Jang, Changheui
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1142-1153
    • /
    • 2019
  • This paper presents the effect of fusion procedure on the fusion performance of the thermal butt fusion in the safety class III buried HDPE piping per various tests performed, including high speed tensile impact, free bend, blunt notched tensile, notched creep, and PENT tests. The suitability of fusion joints and qualification procedures was evaluated by comparing test results from the base material and buttfusion joints. From the notched tensile test result, it was found that the fused joints have much lower toughness than the base material. It was also identified that the notched tensile test is more desirable than the high speed tensile impact and free bend tests presented in the ASME Code Case N-755-3 as a fusion qualification test method. In addition, with regard to the single low-pressure fusion joint performances, the procedure given by the ISO 21307 was determined to be better that the one specified in the Code Case N-755-3.