• 제목/요약/키워드: Low density

검색결과 7,811건 처리시간 0.039초

뇌경색환자의 고지혈증에 대한 부항요법의 임상적 효과 (Clinical Effect of Cupping Therapy on Cerebral Infarction Patients with Hyperlipidemia)

  • 박회진;황규선;박현애;이창희;박현호;송수철;전성하
    • Journal of Acupuncture Research
    • /
    • 제25권4호
    • /
    • pp.41-49
    • /
    • 2008
  • Objectives : This study was aimed at examining significant curative effects of Cupping therapy on Cerebral infarction patients with hyperlipidemia. Methods : The subjects in this study were fifty-two patients visited or admitted to Dong-seo Oriental Hospital who broke out with Cerebral infarction from March 2007 through February 2008, with high total cholesterol(240mg/$d\ell$ above) or high triglyceride(200mg/$d\ell$ above) or low density lipoprotein(160mg/$d\ell$ above) Before prescription, they were tested for total cholesterol, triglyceride, low density lipoprotein with fasting and were then rescribed the cupping therapy for 4 weeks(take an average ten times), after which they were retested for total cholesterol, triglyceride, low density lipoprotein. Results : 1. In the high total cholesterol group(triglyceride and low density lipoprotein are normal), statistical significance of total cholesterol changes was recognized before and after the treatment. 2. In the high triglyceride group(total cholesterol and low density lipoprotein are normal), statistical significance of triglyceride changes was recognized before and after the treatment. 3. In the high low density lipoprotein group(total cholesterol and triglyceride are normal), statistical significance of triglyceride changes was recognized before and after the treatment. 4. In the high total cholesterol and high triglyceride group(low density lipoprotein is normal), statistical significance of total cholesterol changes was recognized before and after the treatment. But, triglyceride changes was not that. 5. In the high total cholesterol and high low density lipoprotein group(triglyceride is normal), statistical significance of total cholesterol and low density lipoprotein changes were recognized before and after the treatment. 6. In the high triglyceride and high low density lipoprotein group(total cholesterol is normal), statistical significance of triglyceride changes was recognized before and after the treatment. But, low density lipoprotein changes was not that. 7. In the high total cholesterol and high triglyceride and high low density lipoprotein group, statistical significance of total cholesterol changes and low density lipoprotein changes were recognized before and after the treatment. But, triglyceride changes was not that. Conclusions : Cupping therapy decreased total cholesterol in whole hyperlipidemia group including high total cholesterol.

  • PDF

잰킷 행렬을 이용한 저밀도 부호의 구성 (Low Density Codes Construction using Jacket Matrices)

  • 문명룡;이광재;;황기연;이문호
    • 대한전자공학회논문지TC
    • /
    • 제42권8호
    • /
    • pp.1-10
    • /
    • 2005
  • 본 논문에서는 대수 이론과 관련된 일반화된 치환 행렬로부터 저밀도 부호의 명시적 구성을 고찰하였으며, 순환공식과 치환행렬에 관한 재킷 역 블록 행렬을 설계하였다. 설계 결과로부터 제안 기법은 저밀도 부호를 얻기 위한 간단하며, 고속화된 기법임을 알 수 있다. 또한, $\pi$-회전 LDPC(low density parity check) 부호와 같은 구조화 LDPC 부호 역시 저밀도 재킷 역 블록 행렬임을 증명하였다.

Gas and Magenetic Field Effect to Low Pressure Plasma

  • 배인식;나병근;설유빈;유신재;김정형;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.557-557
    • /
    • 2013
  • Plasma hardly grows in lowpressure because of lack of collision. But low pressure plasma has useful properties because it has typically low electron density. In here, thermal electron is used to make breakdown in low pressure easily. We changed magnetic field strength and gas to control electron density or temperature. IV characteristic and electron density of the discharge are examined and the characteristic of the discharge in presence of magnetic field is also examined. Results showed that depending on the ionization cross section of the gas, electron density is changed and proper strength of magnetic field is required for high electron density.

  • PDF

지중배전케이블 기저수지의 수증기 투과 전달특성 (Chararcteristics of Water Vapor Transmission in Base Resin for Underground Residential Distribution Power Cable)

  • 송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.149-153
    • /
    • 2003
  • In URD(Underground Residential Distribution) power cable, experiments of WVT(Water Vapor Transmission) test on the Base Resin accomplished to specimens which contained CB(Carbon Black), anti-oxidant to base resin and made by pressing to resin of pellet or lump form. a kind of specimens was HDPE(High Density Polyethylene), MDPE(Medium Density Polyethylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). as a results of WVT test, we saw that WVT ratio was HDPE < LLDPE < MDPE≒LDPE${\ll}$ PVC. WVT properties of PVC using for jacket showed properties 15-20 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials.

  • PDF

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

등전점초점(等電點焦點) 맞추기 획분법(劃分法)에 의(依)한 극저밀도(極低密度) 혈청(血淸) 지단백질(脂蛋白質) Polypeptide의 특성(特性) (Characterization of Polypeptides From Human Serum Very Low Density Lipoproteins by Isoelectric Focusing Fractionation)

  • 임창택
    • Applied Biological Chemistry
    • /
    • 제16권3호
    • /
    • pp.112-117
    • /
    • 1973
  • The very low density apolipoproteins were separated by a newly developed method of isoelectric focusing in a narrow pH gradient. Four polypeptides were isolated that differed from the major proteins of the high density or low density lipoproteins. Three of these proteins had indistinguishable amino acid compositions, but different isoelectric points, COOH-terminal alanine, no isoleucine, cysteine or cystine. Two of these polypeptides had $NH_2-terminal$ serine. The polymorphism of apolipoprotein-Ala, so designated from the COOH-terminal residue, was related to sialic acid content; one form contained 2 moles of sialic acid per mole of protein, the second, 1 mole of protein, and the third, no sialic acid. The fourth polypeptide had an amino acid composition different from the first three polypeptides and from other polypetides obtained from very low density lipoprotein. This polypeptide had $NH_2-terminal$ threonine, COOH-terminal resistant to carboxypeptidase A, no histidine, cysteine, cystine or sialic acid. These four polypeptides constituted approx. 40% of the total protein in very low density lipoprotein.

  • PDF

Effect of Ensiling Density on Fermentation Quality of Guineagrass (Panicum maximum Jacq.) Silage during the Early Stage of Ensiling

  • Shao, Tao;Wang, T.;Shimojo, M.;Masuda, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권9호
    • /
    • pp.1273-1278
    • /
    • 2005
  • This study is to evaluate the effect of different levels of ensiling density on the fermentation quality of guineagrass silages during the early stage of ensiling. Guineagrass at the milky ripe stage was chopped and ensiled into a small-scale laboratory silo at two ensiling density levels (high density at 95 g/silo and low density at 75 g/silo). Three silos per level were opened after six ensiling periods (0.5, 1, 1.5, 2, 3 and 7 days of ensiling) and the fermentation qualities were analyzed. Within the initial 1.5 days of ensiling there were not significant (p>0.05) differences in the fermentation qualities between two density levels silages, and an almost constant pH and no or only small amounts of lactic acid, acetic acid and total volatile fatty acids were detected. However, the high density silage significantly (p<0.05) increased the rate and extent of fermentation after 1.5 days of ensiling, which was well reflected in significantly (p<0.05) faster and larger pH decline and lactic acid production at each elapsed time as compared with the low density silage. This resulted in significantly (p<0.05) lower finial pH and significantly (p<0.05) higher lactic acid content at the end of the experiment. Moreover, there was higher AA content relative to LA in both the H-D and L-D silages during the full fermentation course, and resulted in the AA-type silage. There were generally somewhat or significantly (p<0.05) higher acetic acid, volatile fatty acids and ammonia-N/total nitrogen in the high density silage than in the low density silage during the initial 3 days of ensiling. However, there were higher (p>0.05) ammonia-N/total nitrogen and significantly (p<0.05) higher butyric acid content in the low density silage at day 7 of ensiling. The silages of two density levels showed an initial increase in glucose between 0.5 and 1 day for the high density silage and between 1 and 1.5 days for the low density silage, respectively, thereafter showed a large decrease until the end of the experiment. There were not large differences (p>0.05) in ethanol content between the low density and high density silages that showed small amounts within initial 3 days of ensiling. However, the low density silage had a significantly (p<0.05) higher ethanol content than the high density silage at the end of experiment. From the above results it was suggested that the increase in ensiling density was an effective method to improve the fermentation quality, especially for tropical grasses.

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.

REPEATED LOW-DENSITY BURST ERROR DETECTING CODES

  • Dass, Bal Kishan;Verma, Rashmi
    • 대한수학회지
    • /
    • 제48권3호
    • /
    • pp.475-486
    • /
    • 2011
  • The paper deals with repeated low-density burst error detecting codes with a specied weight or less. Linear codes capable of detecting such errors have been studied. Further codes capable of correcting and simultaneously detecting such errors have also been dealt with. The paper obtains lower and upper bounds on the number of parity-check digits required for such codes. An example of such a code has also been provided.

LOW-DENSITY CLOSE-CLOSED LOOP BURST ERROR DETECTING CODES

  • Dass, Bal-Kishan;Jain, Sapna
    • Journal of applied mathematics & informatics
    • /
    • 제9권1호
    • /
    • pp.231-238
    • /
    • 2002
  • In this paper, we study cyclic codes detecting a subclass of close-closed loop bursts viz. low-density close-closed loop bursts. A subclass of CT close-closed loop berets called CT low-density close-closed loop bursts is also studied.