• Title/Summary/Keyword: Low Pressure Stage

검색결과 312건 처리시간 0.021초

왕복동 압축기의 성능에 대하여 (THE CHARACTERISTIC OF A TWO STAGE AMMONIA RECIPROCATING COMPRESSOR)

  • 조권옥;오후규
    • 한국수산과학회지
    • /
    • 제10권1호
    • /
    • pp.65-69
    • /
    • 1977
  • The characteristics of two stage compressor which is constituted of two separated reciprocating compressors was tested measuring the volumetric efficiency of each compressor at suction of both bighandlowpressdresideusillgorificetypeflolrmeters. The volumetric efficiency of low pressure side compressor was lower than that of the high side when they were operating under the same compression ratio. And it tended to reduce obviously by lowering evaporating temperature resulting in a markable reduction of refrigerating capacity at the same time. It is assumed that the falling of volumetric efficiency at low side compressor was directed by the decrease in evaporating temperature which derives the falls of gas pressure at suction, increase in compression ratio, and gas flow resistance at suction and discharge valves.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

액화질소 초저온과 이원냉동 초저온 냉열의 비교 실험적 연구 (A Study on the Cold Energy for Liquefied Nitrogen Gas and Cascade Refrigeration System)

  • 김철수;장현순;정효민;정한식
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.56-62
    • /
    • 2007
  • This paper represents the cold energy for liquefied nitrogen gas and cascade refrigerator. In this study, the vaporizer of liquefied nitrogen gas has the fin coil tube type with the dimension of inside diameter of 10mm and outside diameter of 12mm. Also, the total length of vaporizer is 20,000mm. The main experimental parameters are the mean velocity in duct and the supplied flow-rates of liquefied nitrogen gas. For the cascade refrigeration system, the refrigerants are ethane(R 170) in the high pressure stage and R 22 in the low pressure stage.

  • PDF

개별적 저 나트륨 투석 액 적용이 말기 신부전증 환자의 혈압, 투석 간 체중 증가, 갈증 및 투석 중 불편감에 미치는 영향 (Effect of Individual Low Sodium Dialysate on Blood Pressure, Interdialytic Weight Gain, Thirst and Intradialytic Discomfort In End-Stage Renal Disease Patients)

  • 김상숙;최영실
    • Journal of Korean Biological Nursing Science
    • /
    • 제21권3호
    • /
    • pp.169-177
    • /
    • 2019
  • Purpose: The purpose of this paper was to identify blood pressure, interdialytic weight gain, thirst and intradialytic discomfort in subjects after applying individual low-sodium dialysis fluid (1,2,3 mEq/L) to hemodialysis patients for 12 weeks. Methods: This study was a non-equivalent pre-post design. For 12 weeks, dialysate concentration was maintained at 1 mEq/L or 2 mEq/L or 3 mEq/L based on average sodium concentration of each individual, and the difference was compared after applying individually. Results: Change in blood pressure significantly decreased in the group where in pre-hemodialysis systolic pressure decreased the gradient of sodium concentration in serum sodium and dialysis solution by 2mEq/L. Interdialytic weight gain, and thirst showed significant decrease in all three groups. But in all three groups, intradialytic discomfort among dialysis showed no significant changes. Conclusion: Although application of low sodium dialysis fluid showed no change in intradialytic discomfort, lowered blood pressure, thirst, and interdialytic weight gain, which could be used for individual showing increased interdialytic weight gain and increased blood pressure. There is need for continued study on this.

저온 압력용기용 SA516강의 응력비에 따른 피로크랙 전파특성에 관한 연구 (A Study on the Stress ratio affect on the Fatigue Crack Characteristics of Pressure Vessel SA516 Steel at Low Temperature)

  • 박경동;하경준;박형동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1228-1236
    • /
    • 2001
  • In this study, CT specimens were prepared from ASTH A5l6 steel which was used for pressure vessel plates for moderate and lower temperature service. And we got the fellowing characteristics from fatigue crack growth test carried out in the environment of room and low temperature at $25^{\circ}C$ , $-30^{\circ}C$, $-60^{\circ}C$, $-80^{\circ}C$, $-100^{\circ}C$ and $-120^{\circ}C$ and in the range of stress ratio of 0.1, 0.3 by means of opening mode displacement. At the constant stress ratio, the Threshold stress intensity factor range ΔAKth in the early stage of fatigue crack growth (Region I) and stress intensity factor range $\DeltaK$ in the stable of fatigue crack growth (Region II) was increased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region. The straight line slope relation of logarithm da/dN-$\Delta$K in Region II that is, the fatigue clack growth exponent m increased with descending temperature at the constant stress ratio. It assumed that the fatigue crack growth rate da/dN is rapid in proportion to descend temperature in Region II and the cryogenic-brittleness greatly affect a material with decreasing temperature.

  • PDF

저온 압력용기용 SA516강의 응력비에 따른 피로크랙 전파특성에 관한 연구 (A Study of Stress ratio on the Fatigue Crack Growth Characteristics of Pressure Vessel SA516 Street at Low Temperature)

  • 박경동;하경준
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2001년도 춘계학술발표대회 개요집
    • /
    • pp.220-223
    • /
    • 2001
  • In this study, CT specimens were prepared hem ASTM SA516 which was used for pressure vessel plates for room and low temperature service. And we got the following characteristics from fatigue crack growth test carried out in the environment of room and low temperature at $25^{\circ}C$, -3$0^{\circ}C$, -6$0^{\circ}C$, -8$0^{\circ}C$, -l$0^{\circ}C$ and -l2$0^{\circ}C$ and in the range of stress ratio of 0.1, 0.3 by means of opening mode displacement. At the constant stress ratio, the threshold stress intensity factor range ΔK$_{th}$ in the early stage of fatigue crack growth ( Region I ) and stress intensity factor range ΔK in the stable of fatigue crack growth ( Region II) was increased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region. The straight line slope relation of logarithm da/dN - ΔK in Region II, that is, the fatigue crack growth exponent m increased with descending temperature at the constant stress ratio. It assumed that the fatigue crack growth rate da/dN is rapid in proportion to descend temperature in Region H and the cryogenic-brittleness greatly affect a material with decreasing temperature.e.greatly affect a material with decreasing temperature.

  • PDF

저압가스질화에서 탄소강의 초기 화합물층 형성 거동 (Behavior of Initial Formation of Iron Nitride on Carbon Steel at Low Pressure Gas Nitriding)

  • 김윤기;김상권
    • 한국표면공학회지
    • /
    • 제44권3호
    • /
    • pp.75-81
    • /
    • 2011
  • Growth behaviors of iron-nitride on S45C steels at low pressure gas nitriding were examined. Surfaces of the steels covered with fine and porous oxide during the pre-oxidation using $N_2O$ gas. Well faceted particles connected with them were observed after 1 min nitriding. They grew steadily and filled inter-pores during additional nitriding process. From the X-ray diffraction analysis, ${\gamma}'$-iron nitride was dominantly formed at the initial stage but the amount of ${\varepsilon}$-iron nitride was rapidly increased as nitriding treatment time. The porous layer was formed on the particles and thickened up to half of nitride layer after 60 min nitriding. The observed growth behaviors were discussed in internal stress related with volume expansion involved in transforming from iron to iron-nitrides.

150 MW급 가스터빈 저압 1단 회전익 교체주기 연장 가능성 연구 (Extension Feasibility on Replacement Cycle of Rotor Blade Equipped for Low Pressure First Stage in a 150 MW Gas Turbine)

  • 임종호;이재헌
    • 플랜트 저널
    • /
    • 제9권4호
    • /
    • pp.31-36
    • /
    • 2013
  • 국내 A 복합발전소에서 운전 중인 150 MW급 가스터빈 저압 1단 회전익의 교체주기 연장가능성을 다각적으로 모색하였다. 제작사가 추천한 24,000 등가운전시간 이상을 사용한 저압 1단 회전익의 외관검사, 열차폐코팅 제거 후 모재의 표면검사 및 균열검사를 각각 실시하였다. 또한 제작사별 150 MW급 가스터빈의 교체주기를 비교 분석하였다. 제작사가 추천한 24,000 등가운전시간 이상이 경과하여 27,000 등가운전시간을 운전한 저압의 외관을 검사한 결과 냉각홀 부위에 다수의 균열이 관찰되었다. 그러나 열차폐코팅을 제거한 상태에서 실시한 모재의 표면검사에서는 균열이 거의 관찰되지 않았으며, 모재까지 진행된 일부 미세 균열에 대해서는 절단면 검사를 통하여 균열깊이가 기능에 영향을 미치지 않는 수준임을 확인하였다. 따라서 본 연구대상 가스터빈 저압 1단 회전익의 교체정비주기는 현행 24,000 등가운전시간에서 3,000 등가운전시간의 연장이 가능할 것으로 보인다. 또한 연구대상 저압 1단 회전익에 대하여 제작사가 추천한 교체주기는 타제작사 1단 회전익 교체주기의 2/3 수준으로 짧게 설정되어 있어 교체주기 연장이 가능할 것으로 판단된다.

  • PDF

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

유체력을 이용한 직동식 비례 유량 조절 밸브에 관한 연구 (A Study on a Direct-Type Proportional Flow Control Valve Utilizing Flowforces)

  • 배상기;현장환;이정오
    • 한국정밀공학회지
    • /
    • 제15권4호
    • /
    • pp.68-75
    • /
    • 1998
  • A one-stage direction and flow control valve was studied theoretically and experimentally. A direction and flow control valve maintains a constant flow rate by changing the spool-orifice area under the variation of valve pressure drop, since the spool-orifice area is varied by the action of flowforces on the spool. A direction and flow control valve has the advantage of simple and low-cost structure compared to a conventional flow control valve utilizing a pressure regulating spool which regulates the pressure drop caused by flow through the metering orifice. The static and dynamic characteristics of a one-stage direction and flow control valve was analyzed. Experimental results on the flow control characteristics of the manufactured valve show satisfactory agreement with simulation results.

  • PDF