• Title/Summary/Keyword: Low Perfusion

Search Result 150, Processing Time 0.034 seconds

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Calcium Modulation of Insulin Secretion in Perfused Pancreata of Obese Zucker Rats

  • Park, Hyun-Ju
    • Preventive Nutrition and Food Science
    • /
    • v.2 no.2
    • /
    • pp.144-148
    • /
    • 1997
  • Insulin secretory response to various calcium concentrations was investigated in 10- to 12-week old male lean and obese Zucker rats using an in vitro pancreatic perfusion procedure. There was no significant difference in insulin secretion response to low, medium, and high calcium concentrations in the lean rat. However, the obese rat shows a characteristics of hypersecretion of insulin. The obese rat pancreas perfused with the low calcium concentration released as low insulin as the lean rat. When perfused with the medium calcium concentration, th obese rat pancreas released twice as much insulin as the lean rat. eh hypersecretory phenomenon was also seen in the obese rat pancreas perfused with the high calcium concentration during the first phase of erfusion period, but his phenomenon was gradually diminished during he second phase of perfusion period. These results indicate that there may be a selective insulin secretory response to the extracellular calcium in he obese Zucker rat pancreas.

  • PDF

INTESTINAL WALL PERMEABILITY STUDY OF RANITIDINE IN DOGS

  • Kim, Ok-Nam;Gordon L. Amidon
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.273-273
    • /
    • 1996
  • Recently a novel in vivo approach in dogs, using a regional segmental intestinal perfusion technique, has been developed. The perfusion tube consists of a highly sophisticated multichannel tube with two inflatable occluding balloons, which are placed in 10cm apart. The tube was introduced orally from the stomach through the upper jejunum under the guidance of solid-state pH meter. In the present study, four healthy dogs were infused in the proximal jejunum on two periods. The two perfusion experiments used the same flow rate, 2 $m\ell$/min, and the same perfusion solution to determine the intrasubject variability. The mean (${\pm}$ S. E.) fractions of ranitidine absorbed calculated from the perfusion data were 21.32${\pm}$2.01% (n=3) (1st period), 27.88 ${\pm}$ 17.54% (n=4) (2nd period), respectively. The effective permeabilities (Peffs${\times}$10$\^$4/) of ranitidine were 1.51${\pm}$0.47cm/sec (n=3) (1st period), 1.50 ${\pm}$ 0.31 cm/sec (n=4) (2nd period), respectively. The pH and osmolarity of perfusion solution were 7.50 ${\pm}$ 0.03 and 300 ${\pm}$ 0.06 mOsm/L, There was no significant intrasubject variation. Mixing equilibrium (steady-state) was reached at about 50 min. l-Phenylalanine was absorbed almost completely. Intrinsic intestinal wall permeability of ranitidine showed low permeable characteristics, suggesting permeability-limited absorption. The absorption of 1-phenylalanine, an actively transported nutrient, was not inhibited by ranitidine. The low intestinal membrane permeability is one of the important factors responsible for the variable oral absorption of ranitidine. Supported by FDA Grant FD01462-04 and KOSEF Grant.

  • PDF

An Assessment of Allograft Function in Canine Single Lung Transplantation (일측 폐이식 실험견에서 이식폐의 기능 평가연구)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1096-1106
    • /
    • 1995
  • We experienced 7 cases of left single lung transplantation in 14 mongrel dogs and analyzed graft lung function by hemodynamics, blood gas analysis, chest X-ray, biopsy and perfusion lung scan. We performed right pulmonary artery cuff[PA cuff for analysis of graft lung function in 3 cases. The donor lungs were flushed with modified Euro-Collins solution[n=3 or low potassium dextran glucose solution[n=4 and preserved for 4 to 5 hours[n=4 or 24 hours[n=3 at 10o C and implanted to the dogs with similar weight . Assessment of left graft lung was done by occluding the right pulmonary artery for 10 minutes using PA cuff. Assessment for graft lung function was done immediately after an operation and after 3 days, 7days and 3 weeks postoperatively. Four dogs survived for 3days, 7days[2 cases and 3 weeks respectively. Other three dogs expired within 3 hours of reperfusion. Immediate perfusion scans of left lung in four survived dogs after reperfusion were 42.1%, 36% , 11% and 5.9% respectively, and another dog with 4.8% perfusion to left lung was dead due to left atrial thrombi after 3 hours reperfusion. In one case among three acute rejections follow-up perfusion scan was done on 3rd and 11th postoperative day and the result decreased from 36% perfusion immediate postoperatively to 21% and 15% respectively. Three expired dogs postoperatively couldn`t tolerate occlusion of right pulmonary artery with above 40 mmHg of mean pulmonary artery pressure. On the other hand, three survival dogs postoperatively tolerated occlusion of right pulmonay artery with less than 30 mmHg of mean pulmonary artery pressure. and one dog couldn`t tolerate same procedure immediate postopertively but in 2 hours reperfusion later tolerated with 29 mmHg of mean pulmonary artery pressure.In conclusion we couldn`t compare the effect of two flushing solutions but low potassium dextran glucose solution showed relatively safe preservation effect in cases with preservation of more than 20 hours. Also canine left single lung transplantation model with PA cuff indicated useful method for the assessment of graft lung function with effect of lung preservation.

  • PDF

Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation (소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향)

  • Lee Seung-Jun;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF

A Light Control Algorithm for Pulse Oximeter (펄스옥시미터 시스템의 광조절 알고리즘 구성 방법)

  • Kang, Min-Soo;Lee, Jeong-Whan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.229-231
    • /
    • 2012
  • 본 논문에서는 펄스옥시미터 시스템의 측정 신뢰성 향상을 위해 Perfusion Index값을 이용한 광량조절의 방법을 제시한다. 본 방법은 펄스옥시미터의 광출력 값의 조정을 미약한 신호 상황에 대한 적응 가능한 광출력을 줄 수 있으며, 산소포화도 측정값의 변화율에 직접적으로 영향을 주는 광량을 보다 정확하게 조절하여 안정적인 측정이 가능하다. 또한 미약한 신호의 측정을 일괄적으로 조절 가능한 기능을 통해 다양한 사람들에게 사용되는 펄스옥시미터의 특성상 보다 정확한 값을 제공할 수 있다.

  • PDF

Value of Perfusion Weighted Magnetic Resonance Imaging in the Diagnosis of Supratentorial Anaplastic Astrocytoma

  • Lee, Kyung Mi;Kim, Eui Jong;Jahng, Geon-Ho;Park, Bong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.3
    • /
    • pp.261-264
    • /
    • 2014
  • We report perfusion weighted imaging (PWI) findings of nonenhanced anaplastic astrocytoma in a 30-year-old woman. Brain magnetic resonance imaging showed a nonenhanced brain tumor with mild peritumoral edema on the right medial frontal lobe and right genu of corpus callosum, suggesting a low-grade glioma. However, PWI showed increased relative cerebral blood volume, relative cerebral blood flow, and permeability of nonenhanced brain tumor compared with contralateral normal brain parenchyma, suggesting a high-grade glioma. After surgery, final histopathological analysis revealed World Health Organization grade III anaplastic astrocytoma. This case demonstrates the importance of PWI for preoperative evaluation of nonenhanced brain tumors.

The usability of the MR Breast perfusion image and Time-Signal Intensity curve in Breast cancer patients (유방암 환자에서 MR Breast perfusion 영상과 시간-신호강도 곡선의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4068-4074
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of MR Breast perfusion image and time-signal intensity curve in patients diagnosed with breast cancer. We selected on 20 patients who were histologically diagnosed to have invasive ductal carcinoma (IDC) from March 2009 to December 2010. First, the Breast perfusion mapping image was reconstructed after obtaining the dynamic contrast enhancement image. The reconstructed image measured the slope, maximal relative enhancement, and time to peak on the detail including the lesion region, normal region, back ground region after obtaining the time-signal intensity curve. The lesion region and normal and slope of the back ground part were measured with the quantitive analytical method about the research and the average was compared and was analyze. In the qualitative analysis, the signal strength of each pixel was analyze with the macroscopic and being high it was low, the medium (2) performed the division of (a) by the three-point standard and the average was measured. The findings from the quantitative image analysis are the following: In the lesion region, the slope and maximal relative enhancement were the highestest among and the time to peak was the highestest in the back ground region. In the qualitative analysis, the breast perfusion image showed a diagnostic efficiency.

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.