• 제목/요약/키워드: Low Energy

Search Result 11,965, Processing Time 0.124 seconds

Floor Plan Analysis of Detached Houses for the Low-income Households

  • Kim, Junghwa;Ahn, Byunglip;Jang, Cheolyong;Jeong, Hakgeun;Kim, Jonghun
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.39-45
    • /
    • 2014
  • Energy poverty has been defined as low-income households who paid energy cost more than 10% of their ordinary income. Therefore, there are various subsidy programs focused on house remodeling for low-income households and one of them is the Home Energy Efficiency Assistance Program which have done by Korea Energy Foundation since 2007. The aim of the program is to improve the thermal performance of dilapidated dwellings and analyzed the detached house for the low-income households to develop the building typology. The database contained approximately 3,061 households which was obtained from the program in 2013 and the results of the study were like this; 1) For the shape of residential houses, the number of rectangular shaped building was higher than non-rectangular shaped ones. 2) For the orientation of buildings, the south layout of the detached housing was dominant to gain heating energy into buildings. 3) For the floor area, the average floor area was $44.2m^2$, although its size varied wide variations, which range from $6.3m^2$ to $107.1m^2$. 4) For the windows and doors, the south-facing window was larger than the other side. Finally it would be possible to determine the characteristics of residential houses for low-income families. A future study could establish typology of low-income housing that it would estimate the performance of each model building before and after the retrofit to improve the energy performance.

MEVVA ion Source And Filtered Thin-Film Deposition System

  • Liu, A.D.;Zhang, H.X.;Zhang, T.H.;Zhang, X.Y.;Wu, X.Y.;Zhang, S.J.;Li, Q.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.2
    • /
    • pp.55-57
    • /
    • 2002
  • Metal-vapor-vacuum-arc ion source is an ideal source for both high current metal ion implanter and high current plasma thin-film deposition systems. It uses the direct evaporation of metal from surface of cathode by vacuum arc to produce a very high flux of ion plasmas. The MEVVA ion source, the high-current metal-ion implanter and high-current magnetic-field-filtered plasma thin-film deposition systems developed in Beijing Normal University are introduced in this paper.

  • PDF

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

Comparative Evaluation of Steam Gasification Reactivity of Indonesian Low Rank Coals (인도네시아 저등급 석탄의 스팀 가스화 반응성 비교 평가)

  • KIM, SOOHYUN;VICTOR, PAUL;YOO, JIHO;LEE, SIHYUN;RHIM, YOUNGJOON;LIM, JEONGHWAN;KIM, SANGDO;CHUN, DONGHYUK;CHOI, HOKYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.693-701
    • /
    • 2016
  • Steam gasification of low rank coals is possible at relatively low temperature and low pressure, and thus shows higher efficiency compared to high rank coals. In this study, the gasification reactivity of four different Indonesian low rank coals (Samhwa, Eco, Roto, Kideco-L) was evaluated in $T=700-800^{\circ}C$. The low rank coals containing $53.8{\pm}3.4$ wt% volatile matter in proximate analysis and $71.6{\pm}1.2$ wt% carbon in ultimate analysis showed comparable gasification reactivity. In addition, $K_2CO_3$ catalyst rapidly accelerated the reaction rate at $700^{\circ}C$, and all of the coals were converted over 90% within 1 hour. The XRD analysis showed no significant difference in carbonization between the coals, and the FT-IR spectrum showed similar functional groups except for differences due to moisture and minerals. TGA results in pyrolysis ($N_2$) and $CO_2$ gasification atmosphere showed very similar behavior up to $800^{\circ}C$ regardless of the coal species, which is consistent with the steam gasification results. This confirms that the indirect evaluation of the reactivity can be made by the above instrumental analyses.

An Energy-Efficient Broadcast Method based on Nack Mechanism for Bluetooth Low Energy Environment (Bluetooth Low Energy 환경에서 에너지 효율을 위한 Nack 기반 Broadcast 전송 기법 연구)

  • Jung, Yeon-Seung;Son, Bong-Ki;Lee, Jae-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.457-459
    • /
    • 2015
  • Bluetooth Low Energy 기술은 IoT 환경의 개인 영역 통신 시스템의 발달과 함께 저전력 근거리 통신 기술의 대표되는 기술로써 현재까지 에너지 효율을 우선시하여 개발되어 왔다. 하지만 홈 네트워크 환경이나 공공지역에서 서비스되는 음성안내 등의 환경에서 Bluetooth Low Energy 기술이 적용될 경우 Broadcast 형태의 음성 데이터 전달이 요구될 수 있으며, 이 경우 Bluetooth Low Energy를 포함한 대부분의 저전력 근거리 통신 기술에서는 Duty Cycle 등의 에너지 고효율 정책으로 인하여 Broadcast 데이터 수신에 대한 신뢰성이 보장되기 힘들기 때문에, 보편적으로 n-repetition 방식의 데이터 전달 방식을 적용하고 있다. 본 고에서는 이러한 n-repetition 방식의 데이터 전달에 대한 중복 송신에서 발생되는 에너지 소모를 개선시키고자 Nack 기반의 선택적 재전송 형태의 새로운 Broadcast 기법을 제안하며, 실험을 통하여 이에 대한 효율성을 검증하였다.

Production Performance and Carcass Characteristics of Malpura and Mutton Synthetic Lambs Fed Low and High Energy Rations in a Semiarid Region of India

  • Singh, N.P.;Sankhyan, S.K.;Prasad, V.S.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.5
    • /
    • pp.655-659
    • /
    • 2003
  • Forty eight lambs (24 each of Malpura and Mutton synthetic breeds) were weaned at 90 days of age and divided into two groups. One group of 12 lambs from each of the two breeds was maintained on low energy (52% TDN) and the other group of 12 on high energy (58% TDN) feedlot ration until 6 of the lambs attained 20 kg and the other 6 attained 25 kg live weight in each of the two groups. Daily feed intake and weekly body weights were recorded. Conventional metabolism trials were conducted on the two breeds and the two rations. The growth rate was found to be higher for lambs on high energy ration (p<0.01). The growth rate was also higher for higher target weight groups (p<0.01). The breed did not significantly affect the live weight gains. Mutton synthetic lambs required less number of days to reach 20 kg live weights but took more time to reach 25 kg target weight as compared to Malpura lambs (p<0.01). The lambs of both the breeds reached 25 kg live weight earlier on high energy than those on low energy ration (p<0.01). The dry matter intake, irrespective of breed, was significantly higher (4.57% or 93.4 g per kgW$^{0.75}$) on low energy than that on high energy ration (4.20% or 87.2 g per kg W$^{0.75}$). The digestibility coefficients of all the nutrients excepting crude fibre were significantly higher on high energy diet irrespective of the breed. Lambs on low energy ration, however, digested the crude fibre more than those on the high energy ration (p<0.05). Although there were no significant differences in the intakes of nitrogen, calcium and phosphorus, the balance of nitrogen was higher on high energy ration. The DCP and TDN values were 9.70 and 52.76% for low energy and 9.89 and 57.68 % for high energy ration, respectively. The dressing percentages on live weight basis were 50.2 on low and 51.6 on high energy ration, 50.5 at 20kg and 51.3 at 25 kg slaughter weight and 51.0 in Malpura and 50.8 in Mutton synthetic lambs, respectively. The percent of bones in the carcass was higher on low energy ration in Mutton synthetic lambs at 20 kg slaughter weight than others. It was concluded that the performance of the lambs in respect of mutton production was significantly better on high energy ration fed upto 25 kg slaughter weight with no or little breed differences.

Characteristics for making the mask of low-energy EPL (Low-energy EPL 마스크 구현을 위한 특성 연구)

  • 김태근;함동은;신수범;김우삼;김치호;정용재;안진호
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.191-194
    • /
    • 2003
  • Low energy EPL용 마스크 구현을 위한 특성을 연구하였다. Monte Carlo 법을 이용하여 시뮬레이터를 제작하였고, pattern side wall의 slope와 membrane의 Thickness, 전자빔의 가속전압에 따른 전자빔의 거동을 확인함을 통하여 Low energy EPL용 마스크 제작을 위한 spec.을 도출하였다. 또한 실제 제작을 위한 기초단계로 Si etching을 수행하였으며, mask 제작법에 대한 가능성을 확인할 수 있었다.

  • PDF

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

Energy Conversion Efficiency Improvement of Piezoelectric Micropower Generator Adopting Low Leakage Diodes (저누설 다이오드를 사용한 저전력 압전발전기의 효율 개선에 관한 연구)

  • Kim, Hye-Joong;Kang, Sung-Muk;Kim, Ho-Seong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.938-943
    • /
    • 2007
  • In this paper, we show that, in case of piezoelectric micropower generator, just replacing Schottky diodes in the bridge rectifier with ultra-low reverse leakage current diodes improves the mechanical-to-electrical energy conversion efficiency by more than 100%. Experimental and PSPICE simulation results show that, due to the ultra-low leakage current, the charging speed of the circuit employing PAD1 is higher than that of the circuit employing Schottky diodes and the saturation voltage of the circuit employing PAD1 is also higher. This study suggests that , when the internal impedance of source is very large (a few tens of $M{\Omega}$) such that maximum charging current is a few microamperes or less, in order to realize literally the energy scavenging system, ultra-low reverse leakage current diodes should be used for efficient energy conversion. Since low-level vibration is ubiquitous in the environment ranging from human movement to large infrastructures and the mechanical-to-electrical energy conversion efficiency is much more critical for use of these vibrations, we believe that the improvement in the efficiency using ultra-low leakage diodes, as found in this work, will widen greatly the application of piezoelectric micropower generator.

A BIM-based Design Method for Energy-Efficient Housing (BIM 기반의 저에너지 주거공간 설계 기법 연구)

  • Yoon, Seung-Hyun;Park, Nam-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.187-192
    • /
    • 2009
  • Nowadays, global warming and high oil prices were a threat to the survival of the whole human race. One of a solution to respond to these problems is to reduce energy consumption of building. By adopting energy-saving design, the dissemination of low energy building is required. Therefore, to improve energy efficiency while reducing the usage of the design method is necessary to study actively. BIM-based systems applied to buildings, scheduled to be built by reducing the amount of energy reduction technologies can be analyzed. Depending on various design and equipment to set energy savings goals, you can select an alternative. If it is possible to predict the energy efficiency from the initial stage of design and support designing low energy building, we would be able to expect improvement in the economics of housing due to the reduction of energy consumption.

  • PDF