• Title/Summary/Keyword: Low Dose

Search Result 2,926, Processing Time 0.039 seconds

Successful engraftment after infusion of multiple low doses of CD34+ cells from a poorly matched sibling donor in a patient with severe aplastic anemia

  • Kum, Chang Dae;Lee, Mi Jin;Park, Jun Eun
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.148-151
    • /
    • 2019
  • The dose of CD34+ cells is known to influence the outcome of allogeneic peripheral blood stem cell (PBSC) and/or T-cell-depleted transplantation. A previous study proposed that $2{\times}10^6\;CD34+\;cells/kg$ is the ideal minimum dose for allogeneic transplantation, although lower doses did not preclude successful therapy. In the case we present here, CD34+ cells were collected from a matched sibling donor on the day of allogeneic hematopoietic stem cell transplantation; however, the number of cells was not sufficient for transplantation. Consequently, PBSCs were collected three additional times and were infused along with cord blood cells from the donor that were cryopreserved at birth. The cumulative dose of total nuclear cells and CD34+ cells was $15.9{\times}10^8\;cells/kg$ and $0.95{\times}10^6\;cells/kg$, respectively. White blood cells from this patient were engrafted on day 12. In summary, we report successful engraftment after infusion of multiple low doses of CD34+ cells in a patient with severe aplastic anemia.

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

PREVENTION OF CIGARETTE SMOKE INDUCED LUNG CANCER BY LOW LET IONIZING RADIATION

  • Sanders, Charles L.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.539-550
    • /
    • 2008
  • Lung cancer is the most prevalent global cancer, ${\sim}90%$ of which is caused by cigarette smoking. The LNT hypothesis has been inappropriately applied to estimate lung cancer risk due to ionizing radiation. A threshold of ${\sim}1\;Gy$ for lung cancer has been observed in never smokers. Lung cancer risk among nuclear workers, radiologists and diagnostically exposed patients was typically reduced by ${\sim}40%$ following exposure to <100 mSv low LET radiation. The consistency and magnitude of reduced lung cancer in nuclear workers and occurrence of reduced lung cancer in exposed non-worker populations could not be explained by the HWE. Ecologic studies of indoor radon showed highly significant reductions in lung cancer risk. A similar reduction in lung cancer was seen in a recent well designed case-control study of indoor radon, indicating that exposure to radon at the EPA action level is associated with a decrease of ${\sim}60%$ in lung cancer. A cumulative whole-body dose of ${\sim}1\;Gy$ gamma rays is associated with a marked decrease in smoking-induced lung cancer in plutonium workers. Low dose, low LET radiation appears to increase apoptosis mediated removal of $\alpha$-particle and cigarette smoke transformed pulmonary cells before they can develop into lung cancer.

Dosimetric comparison of IMRT versus 3DCRT for post-mastectomy chest wall irradiation

  • Rastogi, Kartick;Sharma, Shantanu;Gupta, Shivani;Agarwal, Nikesh;Bhaskar, Sandeep;Jain, Sandeep
    • Radiation Oncology Journal
    • /
    • v.36 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • Purpose: To compare the dose distribution of three-dimensional conformal radiation therapy (3DCRT) with intensity-modulated radiation therapy (IMRT) for post-mastectomy radiotherapy (PMRT) to left chest wall. Materials and Methods: One hundred and seven patients were randomised for PMRT in 3DCRT group (n = 64) and IMRT group (n = 43). All patients received 50 Gy in 25 fractions. Planning target volume (PTV) parameters-$D_{near-max}$ ($D_2$), $D_{near-min}$ ($D_{98}$), $D_{mean}$, $V_{95}$, and $V_{107}$-homogeneity index (HI), and conformity index (CI) were compared. The mean doses of lung and heart, percentage volume of ipsilateral lung receiving 5 Gy ($V_5$), 20 Gy ($V_{20}$), and 55 Gy ($V_{55}$) and that of heart receiving 5 Gy ($V_5$), 25 Gy ($V_{25}$), and 45 Gy ($V_{45}$) were extracted from dose-volume histograms and compared. Results: PTV parameters were comparable between the two groups. CI was significantly improved with IMRT (1.127 vs. 1.254, p < 0.001) but HI was similar (0.094 vs. 0.096, p = 0.83) compared to 3DCRT. IMRT in comparison to 3DCRT significantly reduced the high-dose volumes of lung ($V_{20}$, 22.09% vs. 30.16%; $V_{55}$, 5.16% vs. 10.27%; p < 0.001) and heart ($V_{25}$, 4.59% vs. 9.19%; $V_{45}$, 1.85% vs. 7.09%; p < 0.001); mean dose of lung and heart (11.39 vs. 14.22 Gy and 4.57 vs. 8.96 Gy, respectively; p < 0.001) but not the low-dose volume ($V_5$ lung, 61.48% vs. 51.05%; $V_5$ heart, 31.02% vs. 23.27%; p < 0.001). Conclusions: For left sided breast cancer, IMRT significantly improves the conformity of plan and reduce the mean dose and high-dose volumes of ipsilateral lung and heart compared to 3DCRT, but 3DCRT is superior in terms of low-dose volume.

Analysis of Individual Exposure Dose of Workers and Clinical Practice Students in Radiation Management Area (방사선관리구역내의 종사자 및 임상실습 학생의 개인피폭선량 비교 분석)

  • Lee, Joo-Ah
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.383-388
    • /
    • 2017
  • The purpose of this study was to compare radiation dose among workers in the radiation zone and to compare the doses of students in clinical practice in the same area to provide basic data on optimization of radiation protection. The subjects were 121 radiation related workers, 36 radiation workers, and 121 students who completed 8 weeks of clinical practice from Jan. 2016 to Dec. The depth and surface dose between the radiation related workers and the radiation workers were the highest with $.7440{\pm}1.676mSv$ and $.7753{\pm}1.730mSv$, respectively, and statistically significant (p<.01). Among the three groups, the depth dose was the highest at $.143{\pm}.136mSv$ for clinical practice students and the highest at surface dose of $.1513{\pm}.139mSv$. The lowest in both cases, The mean difference between the two groups was statistically significant (p<.01). In conclusion, it is necessary to manage thoroughly according to the ALARA(As Low As Reasonably Achievable) principle. Especially, it is necessary to systematically manage the dose of radiation for clinical students who are in the blind spot of radiation safety management.

Effect of high-dose ginsenoside complex (UG0712) supplementation on physical performance of healthy adults during a 12-week supervised exercise program: A randomized placebo-controlled clinical trial

  • Lee, Eon Sook;Yang, Yun Jun;Lee, Jun Hyung;Yoon, Yeong Sook
    • Journal of Ginseng Research
    • /
    • v.42 no.2
    • /
    • pp.192-198
    • /
    • 2018
  • Background: Ginseng has been used as an ergogenic agent, although evidence for its effectiveness is weak. A randomized, double-blind, placebo-controlled clinical trial was conducted to evaluate the effect of a ginsenoside complex (UG0712) on changes in exercise performance. Methods: Sedentary individuals (n = 117) were randomly assigned into one of three groups: low-dose ginsenoside supplementation (100 mg/d, n = 39), high-dose ginsenoside supplementation (500 mg/d, n = 39), or a placebo group (500 mg/d, n = 39). All participants underwent a supervised 12-wk aerobic and resistance exercise training course. To assess the effects of supplementation on physical performance, maximal oxygen consumption ($VO_2max$), anaerobic threshold (AT), lactic acid, and muscle strength of the dominant knee were measured at baseline, every visit, and after the training program. Results: Both ginsenoside groups showed significant increases in $VO_2max$ and muscular strength during exercise training. There were no definite changes in AT and lactic acid levels over time. After exercise training, there were definite differences in the $VO_2max$ (28.64.9 to $33.7{\pm}4.9ml/kg/min$ in high-dose group vs. $30.4{\pm}6.7$ to $32.8{\pm}6.6ml/kg/min$ in placebo, p = 0.029) and AT ($19.3{\pm}4.2$ to $20.9{\pm}3.5ml/kg/min$ in high-dose group vs. $20.0{\pm}5.1$ to $20.0{\pm}4.9ml/kg/min$ in placebo, p = 0.038) between the high-dose ginsenoside and placebo groups. However, there was no difference in $VO_2max$ between the low-dose ginsenoside and placebo groups (p = 0.254). There were no differences in muscular strength during exercise training among the three groups. Conclusion: High-dose ginsenoside supplementation (UG0712) augmented the improvement of aerobic capacity by exercise training.

Change of absolute neutrophil count after intravenous immunoglobulin administration for the children with idiopathic thrombocytopenic purpura (특발성혈소판감소성자반증 환아에서 정주용 면역 글로불린 투여 후 절대 호중구 수치의 변화)

  • Shin, Hyun Jung;Bang, In Kug;Choe, Byung Kyu;Hwang, Jin-Bok;Kim, Jun Sik;Kim, Heung Sik
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.982-986
    • /
    • 2007
  • Purpose : Intravenous immunoglobulin (IVIG) is effective for the treatment of idiopathic thrombocytopenic purpura (ITP) in children. Recently, several reports have been published that show its impact on the absolute neutrophil count. The present study was performed to confirm these findings. Methods : Data on 26 ITP patients were analyzed. Patients with febrile illness or increased C-reactive protein levels at presentation, which would influence the neutrophil counts, were excluded to determine the sole impact of IVIG. In addition, patients who received steroid treatment were also excluded. Results : Sixteen boys and ten girls were analyzed. For patients who received an IVIG dose of 0.4 g/kg/day (n=17), the absolute neutrophil count (ANC) measured next day was significantly decreased. For patients who received an IVIG dose of 1 g/kg/day (n=9), the ANC measured the next day was also significantly decreased. However, the decrease was more profound in the high-dose group compared to the low-dose group. Among six cases with profoundly decreased ANC greater than $1,000/mm^3$, four patients (67%) received IVIG at a dose of 1 g/kg/day. All four cases with increased ANC were treated with IVIG dose of 0.4 g/kg/day, and three cases (75%) among them had a febrile reaction during IVIG administration. None of the cases with decreased ANC had a febrile reaction. No cases had infectious complications reported. Conclusion : IVIG treatment for ITP patients appears to suppress the ANC. This decrease of ANC was more pronounced when a higher dose of IVIG was used. Some cases with increased ANC counts after IVIG use were found only in low-dose IVIG group, and was associated with febrile reactions during IVIG use.

Efficacy and Safety of Human Bone Marrow-Derived Mesenchymal Stem Cells according to Injection Route and Dose in a Chronic Kidney Disease Rat Model

  • Han Kyu Chae;Nayoung Suh;Myong Jin Jang;Yu Seon Kim;Bo Hyun Kim;Joomin Aum;Ha Chul Shin;Dalsan You;Bumsik Hong;Hyung Keun Park;Choung-Soo Kim
    • International Journal of Stem Cells
    • /
    • v.16 no.1
    • /
    • pp.66-77
    • /
    • 2023
  • Background and Objectives: We compared the efficacy and safety of human bone marrow-derived mesenchymal stem cells (hBMSC), delivered at different doses and via different injection routes in an animal model of chronic kidney disease. Methods and Results: A total of ninety 12-week-old rats underwent 5/6 nephrectomy and randomized among nine groups: sham, renal artery control (RA-C), tail vein control (TV-C), renal artery low dose (RA-LD) (0.5×106 cells), renal artery moderate dose (RA-MD) (1.0×106 cells), renal artery high dose (RA-HD) (2.0×106 cells), tail vein low dose (TV-LD) (0.5×106 cells), tail vein moderate dose (TV-MD) (1.0×106 cells), and tail vein high dose (TV-HD) (2.0×106 cells). Renal function and mortality of rats were evaluated after hBMSC injection. Serum blood urea nitrogen was significantly lower in the TV-HD group at 2 weeks (p<0.01), 16 weeks (p<0.05), and 24 weeks (p<0.01) than in the TV-C group, as determined by one-way ANOVA. Serum creatinine was significantly lower in the TV-HD group at 24 weeks (p<0.05). At 8 weeks, creatinine clearance was significantly higher in the TV-MD and TV-HD groups (p<0.01, p<0.05) than in the TV-C group. In the safety evaluation, we observed no significant difference among the groups. Conclusions: Our findings confirm the efficacy and safety of high dose (2×106 cells) injection of hBMSC via the tail vein.