• 제목/요약/키워드: Losses

검색결과 5,298건 처리시간 0.035초

고속 전철용 매입형 영구자석 전동기의 풍량에 따른 열해석 (Thermal Analysis of Traction Motor in the High Speed Train with various Flow Rate)

  • 임재원;이경표;정현교
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.165-170
    • /
    • 2010
  • Recently, Interior Permanent Magnet Machine(IPM) is widely used for traction motor in the high speed train. Higher efficiency and power density are the superb performance of IPM. Due to the high power density, however, it has lots of heat source which are originated from copper losses and core losses. These heat source can cause the permanent demagnetization in magnet and the loss of torque and power. To prevent the undesirable loss in the traction motor, the accurate loss calculation and the thermal analysis should be preceded. Especially, the end-winding area and permanent magnet area should be examined correctly. In this paper, the electromagnetic fields were examined by finite element method to analyze the electromagnetic properties of IPM and thermal analysis are carried out with pre-calculated losses. To validate the analysis result, the experiment set with forced air cooling system is manufactured.

  • PDF

필라멘트 구조의 YBCO 박막의 자기이력 손실 (Hysteresis loss of YBCO thin film strip with filamentary structure)

  • 박현욱;나동현;김맹준;장용식;김지만;이형철;이용호
    • Progress in Superconductivity
    • /
    • 제6권2호
    • /
    • pp.99-103
    • /
    • 2005
  • For ac applications a detailed understanding of the ac power losses associated with different conductor configurations is of crucial importance. YBCO thin films were divided into parallel filaments with widths of 1, 2, and 4 mm to reduce hysteresis losses. The measured hysteresis losses show a linear relationship between the strip width and hysteresis loss as anticipated. The influence of different inter-filament separations on the hysteresis loss is investigated.

  • PDF

손실 저감을 위한 인버터 구동 유도 전동기의 고정자 슬롯 형상 최적화 (Optimal Stator Slot Design of Inverter-Fed Induction Motor for Reduction of Core and Winding Losses)

  • 김재우;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.86-88
    • /
    • 2004
  • In this paper, optimal stator slot shape of 3-phase inverter-fed induction motor is designed to reduce stator core and winding losses. For the analysis, the F.E.M on 1 phase band periodic condition in stator is coupled with harmonic equivalent circuit. For the optimal design, the conjugate gradient method is used as an optimizing algorithm. The stator core and winding losses are reduced by the design method. The results are verified by those of the time-step finite element analysis.

  • PDF

Cu-Al 전도체에서의 홀손실과 자기저항에 관한 연구 (A Study on the Hall losses and Magnetoresistance in Cu-Al Composite Conductor)

  • 김상걸;정일형;김진사;이준웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.408-410
    • /
    • 1997
  • An anomalous magnetoresistance effect has been observed at very low temperatures for composite normal metal conductors. This anomalous behavior is due to transverse Hall currents in the composite which would result in increased $I^2R$ losses and a higher effective resistance for the composite conductor. In this paper, transverse current flow and effective resistance of Cu-Al double-strip was analyzed using finite element method for predicting the Hall losses to be resulted in anomalous magnetoresistance effect, and then be able to visualized.

  • PDF

YBCO CC 적층 및 BSCCO tape 적층선재에서 수직자화 손실 값을 이용한 임의 방향 자화손실 평가 (Magnetization Loss Characteristics at Arbitrary Directional Magnetic Field by Perpendicular Magnetization Loss in YBCO CC and BSCCO Stacked Conductors)

  • 이지광;임형우;박명진;차귀수
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.282-288
    • /
    • 2007
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCOCC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses under various angles of external magnetic field in BSCCO tape stacked conductors and YBCO CC stacked conductors are presented and compared with each other. Also, we present the compared results of magnetization losses measured at arbitrary reaction magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization losses of YBCO CC single and stacked conductors agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO single and stacked conductors are not.

전자계해석을 이용한 고효율 몰드변압기 손실 평가기술 연구 (A study on Loss Evaluation Technology of High Efficiency Mold Transformers using Electromagnetic Field Simulation)

  • 정상훈;이곤;최명준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.774-775
    • /
    • 2015
  • In this paper, a series of electromagnetic analyses carried out for a high efficiency 22.9/0.38kV mold transformer are presented. The simulations were performed in order to calculate the losses which eventually verify the performance(efficiency) of the designed product. Here, losses include core loss, stray losses of non-current carrying metallic structural parts(core plate and clamp), ohmic loss and eddy current loss of current carrying metallic parts(busbars, leads, terminals and windings). The obtained results of the simulations were compared to the test results and showed high level of accuracy. The loss evaluation technology will allow designers avoid any potential over-design or under-design of the high efficiency products, reducing the manufacture cost and development period compared to the conventional experience-based design procedures.

  • PDF

TEIS 모델과 두 영역 모델을 이용한 원심 펌프의 탈 설계 성능 예측 (Off-design Performance Prediction of Centrifugal Pumps by Using TEIS model and Two-zone model)

  • 윤인호;백제현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.574-579
    • /
    • 2000
  • In this study. an off-design performance prediction program for centrifugal pumps is developed. To estimate the losses in an impeller flow passage, two-zone model and two-element in series(TEIS) model are used. At impeller exit. the mixing process occurs with an increase in entropy. In two-zone model. there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller was calculated by using TEIS model. While internal losses in an impeller an automatically estimated by using the above models, some empirical correlations far estimating external losses. far example, disk friction loss, recirculation loss and leakage loss are used. In order to analyze the vaneless diffuser flow. the momentum equations for the radial and tangential directions are used and solved together with continuity and energy equations.

  • PDF

An Improved Zero Voltage Switching Forward DC/DC Converter For Reducing Switching Losses

  • Kim, Eun-Soo;Joe, Kee-Yeon;Park, Hae-Young;Kim, Yoon-Ho;Kim, Choon-Same
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1051-1055
    • /
    • 1998
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

주 스위치의 전도손실을 최소화한 ZVT 부스터 컨버터 (ZVT boost converter with minimizing conduction losses of the main switch)

  • 진기호;강안종;김태우;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2003
  • A ZVT PWM Boost Converter is proposed to reduce current stresses and conduction losses of main switch in a conventional circuit. By attaching resonant inductor Lr1 in parallel with capacitor Cr, the resonant circulating current is diverted to the additional component and then the main switch is subjected to minimum current stresses same as those in their PWM counterparts. Moreover, the operation of the auxiliary switch in a half wave mode to prevent reverse resonant energy from freewheeling can be able to lessen the conduction losses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed circuit.

  • PDF

New Control Strategy for Reducing Switching Losses in Three-Phase Voltage-Source PWM Converters

  • Dong, Xiaopeng;Wang, Zhaoan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.366-373
    • /
    • 1998
  • In this paper, a new control strategy to reduce switching losses in three-phase voltage-source PWM converters is proposed according to Modified-Period-Average-Model (MPAN). The basic concept of this strategy is aimed at calculating the phase control voltages for controlling the source currents to be sinusoidal and in phase with the source voltages, and reducing the number of switching in each period. The phase control voltages of Period-Average-Model(PAM) is obtained according to analyzing the operation of PWM converter. In order to reduce the sensitivity to system parameters in PAM, MPAM is deduced. Then a square wave whose frequency is three times of utility frequency is added to the phase control voltages derived from MPAM. The control strategy reduces the switching losses since there exists about one-third blanking time for every phase in one period. The theoretical derivation and the control strategy are experimentally verified on a 2.5 kW three-phase voltage source converter.

  • PDF