• Title/Summary/Keyword: Loss of field

Search Result 2,339, Processing Time 0.028 seconds

$100 A/mm^2$ Class Bi-2223 Tapes in Electromechanical Devices (전력기기에서 $100 A/mm^2$급 Bi-2223테이프)

  • 류경우;최경주;성기철;류강식
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • $100 A/mm^2$ class Bi-2223 tapes have recently become commercially available. Some important characteristics of the tapes, e .g. critical current, ac loss, characteristics at joint, fault current characteristics, are required for an application such as a power cable or a power transformer. In this paper they have been investigated experimentally. The results indicate that the self-field loss of the high current density tapes is not negligible, compared to resistive loss in a copper wire for the same currents. In a cable, the self-field loss for relatively large currents is much larger than the magnetization loss due to an external field. But in a transformer, the magnetization loss is dominant, compared to the self-field loss. Finally the fault current characteristics show that the high current density tapes are never safe from burn-out even for fault currents with a few cycles.

Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor (자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향)

  • 류경우;김현준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.

AC Loss Characteristics of Multifilamentary HTS Tapes

  • Amemiya, Naoyuki
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.69-72
    • /
    • 2000
  • AC losses in multifilamentary HTS tapes can be classified to hysteresis loss, coupling loss, and eddy current loss from the viewpoint of their generation mechanism. From the viewpoint of the major magnetic field component generating them, they can be classified to magnetization loss, transport loss, and total loss. Dividing superconductor to fine filaments, twisting filaments bundle and increasing transverse resistivity are effectively reduce magnetization loss and total loss when the external magnetic field is relatively large. Recently, twisted multifilamentary Bi 2223 tapes with pure silver matrix were fabricated and the reduction of magnetization loss was proved experimentally in the parallel magnetic field to the tape wide face. However, when the perpendicular magnetic field is applied, increasing transverse resistivity is required essentially to reduce the AC losses. The transverse resistivity was increased successfully by the introduction of resistive barrier between filaments.

  • PDF

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

Calculation of Coupling Loss in a HTS Tape by using Analytic Method and Numerical Method (해석적인 방법과 수치적인 방법에 의한 고온초전도테이프의 결합손실 계산)

  • Sim, Jeong-Uk;Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.309-315
    • /
    • 1999
  • Coupling loss is generated by the time-varying external magnetic field in the normal matrix of the multi-filamentary HTS tape. This paper calculates the coupling loss in the HTS tape. Analytic calculation of the coupling loss cannot consider the effect of the different shapes and the arrangement of the filaments. Numerical calculation by using finite element method and analytic calculation of the coupling loss have been done in this paper and results of two calculations have been compared. Transverse magnetic field and longitudinal magnetic field were considered as the external field.

  • PDF

Effect of an External AC Magnetic field on Dynamic Resistance and Loss Characteristic in a Bi-2223 Tape (외부 교류자장이 Bi-2223테이프의 동저항 및 손실특성에 미치는 영향)

  • Ryu, Kyung-Woo;Choi, Byoung-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.473-477
    • /
    • 2005
  • A Bi-2223 tape has been developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called 'dynamic resistance' We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external at magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results ana discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

Estimation Iron Loss Coefficients and Iron Loss Calculation of IPMSM According to Core Material (철심 재질에 따른 철손 계수 산정 및 IPMSM의 철손 계산)

  • Kang, Bo-Han;Kim, Yong-Tae;Cho, Gyu-Won;Lee, Jung-Gyu;Jang, Ki-Bong;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1269-1274
    • /
    • 2012
  • In this paper, the iron loss was calculated using estimated iron loss coefficient at 650W Interior Permanent Magnet Synchronous Motor(IPMSM) and 250W IPMSM. The iron loss coefficients was estimated different according to electrical steel material used to stator and rotor core in motor. Aspect of The rotating flux field and alternating flux field was confirmed by magnetic field behavior and harmonic analysis in stator core, the iron loss was calculated using flux density by Finite Element Method(FEM) and estimated coefficients by iron loss coefficient estimation proposed in this paper. The iron loss experiment was performed for verified to iron loss calculation, and the iron loss coefficients were verified by comparison of iron loss calculation value and experimental value.

Effect of Bundle icing Forces on the Shattering Loss of Grains (바인다의 효출력이 곡물탈립손실에 미치는 영향)

  • 백풍기;정창주
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.20-36
    • /
    • 1978
  • The effect of binder kicking forces on the shattering losses of paddy rice, which has been widely understood as an outstanding loss factor in harvesting with a binder, were experimentally assessed in this thesis.Through the field tests the optimum time of harvest, in terms of grain moisture contents, was found by considering harvesting losses for two rice varieties, harvested by two different binders, at four or five grain moisture levels.A device was designed and manufactured to apply various kicking forces to the bundles and was used in the bundle kicking tests. It was intended to find out the optimum range of kicking force to minimize the kicking losses. Based on the study, modification of the existing binder kicking mechanism was suggested. The following is a summary of the results of this thesis. 1. In Suweon 258 variety, as the grain moisture content is reduced, so the cutting loss and the kicking loss increase. The grain losses range from 0.77 to 0.82 percent of total field yield for the cutting loss, from 1.83 to 2.01 percent for the kicking loss, and from 2.60 to 2.83 percent for the field loss, when the moisture content is about 22 percent. 2. In Jinheung variety , the field losses increased as the grain moisture content decreased . When the moisture content was 20 percent, the field loss, cutting loss and kicking loss was 0.42-0.49 % , 0.30-0.35, and 0.12 -0.14% of the total field yield, respectively. 3. The difference in the field loss , cutting loss, and kicking loss for the two binders was 0.23% , 0.05% and 0.18% respectively in Suweon 258 variety, and 0.07% , 0.02% and 0.05% respectively ini Jinheung variety. The grain losses for binder B were slightly higher than those for binder A. 4. In the statistical analysis of each variety , the kicking force and the moisture content of the grain, and its interaction were all highly significant at 1% level by T test .The optimum kicking force was found to be in the 3.0-0.4kg range. This does not interrupt the binder operation, while ioses are kept to an acceptale level. 5. To reduce the kicking force of the eXlstmg binder mechanism, the speed of rotation of the kicking arm needs to be redued by increasing the number of driving sprocket teeth, and the position and gear ratio of the knotter-bill and driving bevelgear have to be change to give a !motter-bill speed of 1110 rpm. It is also desirable to attach a belt conveyor which smoothly carries the bundle to the ground. 6. The optimum harvesting time cased on maximum field yield was found to be at a grain moisture content of around 22 percent for Suweon 258 variety, and 20 percent for Jinheung variety. Tota] field yield and field yield at the time amounted to 9, 812.5 kg/ha, 9, 302. 5kg/ha respectively for the Suweon 258, and 7, 819.5 kg/ ha, 7, 158.7 kg/ha respectively for the Jinheung variety.

  • PDF

Measurement of the Self-field Loss in the HTS Tape (고온초전도체의 자기자계손실 측정)

  • Sim, Jung-Wook;Cha, Guee-Soo;Lee, Ji-Kwang;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.274-276
    • /
    • 1999
  • Transport current is the HTS tape generates the self field loss. To measure the self field loss, rectangular voltage tap has been used. In this paper, self field loss was measured using the spiral voltage tap method. Result of the measurement was compared with that of the theoretical.

  • PDF

AC loss of HTS magnet for AMR refrigerator using magnetic field formulation and edge element in cylindrical coordinates

  • Kim, Seokho;Park, Minwon;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • AMR (Active Magnetic Regenerative) refrigerators require the large variation of the magnetic field and a HTS magnet can be used. The amount of AC loss is very important considering the overall efficiency of the AMR refrigerator. However, it is very hard to estimate the precise loss of the HTS magnet because the magnetic field distribution around the conductor itself depends on the coil configuration and the neighboring HTS wires interact each other through the distorted magnetic field by the screening current Therefore, the AC loss of HTS magnet should be calculated using the whole configuration of the HTS magnet with superconducting characteristic. This paper describes the AC loss of the HTS magnet by an appropriate FEM approach, which uses the non-linear characteristic of HTS conductor. The analysis model is based on the 2-D FEM model, called as 'magnetic field formulation and edge-element model', for whole coil configuration in cylindrical coordinates. The effects of transport current and stacked conductors on the AC loss are investigated considering the field-dependent critical current. The PDE model of 'Comsol multiphysics' is used for the FEM analysis with properly implemented equations for axisymmetric model.