공기조화설비(HVAC) 설계시 혼합손실의 정량적 평가방안의 제안 (The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design)

  • 이정재
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.879-885
    • /
    • 2000
  • It is a serious subject for energy conservation to prevent the energy loss caused by mixing of heated and cooled air jets in a building which two types of air-conditioning systems are adopted in perimeter and interior zone. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of the mixing loss and to propose preventive methods for it. In this paper, by using the dynamic heat load calculation method, heat extraction loads of a typical office building in Pusan are calculated. According to the results, numerical simulation based on the computational fluid dynamics were peformed in order to measure the mixing loss in physical size HVAC system. Then, the distributions of air temperature and velocity are analyzed in order to grasp the relations by setting temperature differences influence on the mixing loss.

  • PDF

선박용 HVAC 시스템의 소음저감성능 평가 (Evaluation of Noise Reduction Performance of HVAC System for Ships)

  • 김상렬;김현실;김재승;김봉기;이성현
    • 한국음향학회지
    • /
    • 제29권8호
    • /
    • pp.497-503
    • /
    • 2010
  • 본 논문은 여객선용 HVAC 시스템 목업을 구축하여 HVAC 요소의 성능평가를 수행한 결과를 다루었다. 측정은 룸 유니트 (Room Unit), 소음기 등 6가지 종류에 대해 이루어졌으며 여러 유량에 대해 삽입손실을 측정하였다. 소음기 직경이 작고 유량이 클수록 유동소음이 커져서 소음저감효과를 방해하지만, 직경이 커질수록 유동소음의 효과는 작아지고 삽입손실은 최대 25 dB까지 나타남을 확인하였다. 디퓨저 형태의 룸 유니트는 대체로 삽입손실이 0 - 10 dB 이지만 노즐 형태는 삽입손실이 최대 -15 dB 까지 소음이 커질 수 있음을 확인하였다. 또한 덕트 배열에 따라 최대 2 dB 까지 실내소음이 차이날 수 있음을 보였으며 각 룸 유니트에 동일한 유량이 배출하도록 조절하는 것이 보다 낮은 소음레벨을 얻을 수 있음을 확인하였다.

The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design

  • Yee, Jurng-Jae;Kim, Young-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.62-68
    • /
    • 2001
  • It is a serous subject for energy conservation to prevent the energy loss caused by the mixture of heated and cooled air jets in perimeter and interior zone of a building operated with tow kinds of air-conditioning system simultaneously. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of mixing loss and to propose a evaluation method for it. By using the dynamic heat load calculation, heat extraction load of a typical office building in Busan are calculated. According to the results, numerical simulations based on CFD(Computational Fluid Dynamics) were performed in order to evaluate mixing loss in the physical size of HVAC system. Then, the distributions of air temperature and airflow patterns according to the differences of set-point temperature are analyzed to grasp relations how to influence mixing loss.

  • PDF

선박용 통합 HVAC 소음해석 프로그램 개발 (Development of Integrated HVAC Noise Analysis Program for Ships)

  • 한주범;홍석윤;송지훈;김노성;천승현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.588-593
    • /
    • 2011
  • The Main design parameters of ship HVAC systems are pressure drop and noise analysis of ducts. The Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994), but NEBB's method is not suitable for the ship HVAC systems. In this paper, numerical analysis methods are used to develop a noise prediction method for the ship HVAC systems, especially for large ducts. To develop regression formula of attenuation of sound pressure level in large duct, Boundary Element Method(BEM) is used. Using dynamic loss coefficient which is suggested by ASHRAE fitting data base and numerical methods of HVAC noise analysis, integrated HVAC noise analysis of Program is developed. The developed program can present pressure drop and noise analysis of the ship HVAC systems. To verify the accuracy and convenience of the developed program, prediction of HVAC system for Semi-Submersible Drilling RIG is carried out and the results are compared with measurement of noise level during sea trial.

  • PDF

원전의 공기조화설비(HVAC) 상실사고 분석방법 (Analysis of Loss of HVAC for Nuclear Power Plant)

  • 송동수
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.90-94
    • /
    • 2014
  • 본 논문은 원자력발전소의 내환경기기검증(EQ)을 위한 HVAC 과도분석 방법에 대한 내용을 기술하고 있다. 분석 대상 격실은 비안전관련 HVAC 계통에 의해 공급되는 격실 중에 원자로 안전정지를 담당하는 중요기기가 위치한 구역/격실을 선정하였다. 그리고 해당 HVAC 계통이 공급되는 건물별로 HVAC 과도시 온도조건을 분석하였다. 본 분석을 위해서 GOTHIC 전산코드를 사용하였다. 온도분석 결과는 원자로 보조건물 환기계통(DVN)의 W315/W415 격실에서 $82.2^{\circ}C$로 가장 높은 온도값을 나타내며, 제어봉구동장치 전원공급건물 및 보조급수펌프실(DVG) 계통의 W229 (Auxiliary feedwater pump room) 격실에서 $52.7^{\circ}C$, 기기냉각건물 환기계통(DVI)의 전 격실에서 $42.9^{\circ}C$, 전기건물 주환기 계통(DVL)의 L207 (Hot workshop) 격실에서 $57.3^{\circ}C$를 각각 나타났다. 이러한 온도값은 일반적인 원전의 기기검증 제한값인 $171^{\circ}C$이하이므로 내환경검증 요건을 만족하는 온도이다.

GUI Modeling을 기반으로한 선박의 HVAC System 소음 해석 (The Noise Analysis of Ship HVAC System Based on GUI Modeling)

  • 이철원;김노성;최수현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1300-1305
    • /
    • 2001
  • One of the main noise sources in cabin onboard ships is HVAC system. Up to now, the HVAC system designer manually calculates the HVAC system noise, or uses the program that is generally based on text user interface. In such a case, it is difficult to use the program and also to obtain the flow induced noise. In this study, the HVAC noise analysis program has been developed, which is based on GUI user interface that include 3.D modelling and model modification modules. For calculation of the insertion loss of HVAC system elements, NEBB experimental data and plane wave theory are used. And in order to obtain the flow rate information in each HVAC elements which is used to calculate the flow induced noise calculation, Global Converging Newton-Rapson Method is used.

  • PDF

도파관 배열에 의한 국부저항계수 산정 (Evaluation of Local Loss Coefficients for Different Waveguide-Below-Cutoff (WBC) Arrays of Electromagnetic Pulse (EMP) Shied in Buildings)

  • 방승기;채영태
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.366-372
    • /
    • 2017
  • The objective of this study was to characterize Waveguide-Blow-Cutoff (WBC) array for Electromagnetic Pulse (EMP) shield in air duct or water pipe, the typical pathway of pulse in indoor space with critical electronic device. A numerical investigation with three different WBC designs (circular, rectangular, and hexagonal or honeycomb) was conducted to satisfy recommended shielding effectiveness (SE) levels from 80 dB to 140 dB. Pressure drop between upstream and downstream of EMP shields based on WBC arrays was also investigated to understand air flow feature in air duct of HVAC system. Results showed that honeycomb geometry outperformed other shapes in terms of reducing the depth of EMP shield, thus providing better air flow in duct path with lower local loss coefficient in HVAC system under SE requirements.

등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구 (A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method)

  • 박준석;최길환;조대승
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.