A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

Wear Loss Presumption of Motorcycle Disk Brake Using Regression Analysis (회귀분석을 이용한 모터싸이클 브레이크 디스크의 마멸량 예측)

  • Jeun, Hwan-Young;Bae, Hwo-Jun;Kim, Young-Hee;Ryu, Mi-Ra;Park, Heung-Sik
    • Tribology and Lubricants
    • /
    • v.23 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • The friction test using disk-on-pad type was carried out and regression analysis with friction parameters was applied fur wear loss presumption of motorcycle break disk. The wear loss has an effect on the frictional factor such as applied load, sliding speed, and number of ventilated disk hole. However, it is difficult to know the mutual relation of these factors on wear loss of motorcycle break disk. From this study, the result was shown that the regression analysis equation containing 4 elements were constructed and this equation had a trust of 95% in wear loss presumption of motorcycle break disk. It is possible to apply for another automobile parts.

A Study on the Efficiency Characteristics of the Interleaved CRM PFC using GaN FET (GaN FET를 적용한 인터리브 CRM PFC의 효율특성에 관한 연구)

  • Ahn, Tae-Young;Jang, Jin-Haeng;Gil, Yong-Man
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.65-71
    • /
    • 2015
  • This paper presents the efficiency analysis of a critical current mode interleaved PFC rectifier, in which each of three different semiconductor switches is employed as the active switch. The Si FET, SiC FET, and GaN FET are consecutively used with the prototype PFC rectifier, and the efficiency of the PFC rectifier with each different semiconductor switch is analyzed. An equivalent circuit model of the PFC rectifier, which incorporates all the internal losses of the PFC rectifier, is developed. The rms values of the current waveforms main circuit components are calculated. By adapting the rms current waveforms to the equivalent model, all the losses are broken down and individually analyzed to assess the conduction loss, switching loss, and magnetic loss in the PFC rectifier. This study revealed that the GaN FET offers the highest overall efficiency with the least loss among the three switching devices. The GaN FET yields 96% efficiency at 90 V input and 97.6% efficiency at 240 V, under full load condition. This paper also confirmed that the efficiency of the three switching devices largely depends on the turn-on resistance and parasitic capacitance of the respective switching devices.

Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit (부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계)

  • Byun Jei-Young;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

Characteristics Analysis of Power Capacitor with Unbalanced Voltage Operation (불평형 전압 동작시 전력 커패시터 특성 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.64-72
    • /
    • 2008
  • In the three phase four wire system, voltage unbalance caused by the unbalanced load operation, gives rise to current unbalance and de-rates by the increase of machine's loss and eventually enlarges power capacity and besides has a bad effect on power quality. Power capacitor has been used for the power factor correction of inductive load and the voltage stability of power system. And it uses instead of power side for magnetic excitation of induction motor. If voltage unbalance keeps up, it affects on voltage stress at the power capacitor and finally can be caused breakdown. In this paper, we analysed that voltage and current of power capacitor increases by the voltage unbalance factor and its stress is growing more and more.

Service Deployment Strategy for Customer Experience and Cost Optimization under Hybrid Network Computing Environment

  • Ning Wang;Huiqing Wang;Xiaoting Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.3030-3049
    • /
    • 2023
  • With the development and wide application of hybrid network computing modes like cloud computing, edge computing and fog computing, the customer service requests and the collaborative optimization of various computing resources face huge challenges. Considering the characteristics of network environment resources, the optimized deployment of service resources is a feasible solution. So, in this paper, the optimal goals for deploying service resources are customer experience and service cost. The focus is on the system impact of deploying services on load, fault tolerance, service cost, and quality of service (QoS). Therefore, the alternate node filtering algorithm (ANF) and the adjustment factor of cost matrix are proposed in this paper to enhance the system service performance without changing the minimum total service cost, and corresponding theoretical proof has been provided. In addition, for improving the fault tolerance of system, the alternate node preference factor and algorithm (ANP) are presented, which can effectively reduce the probability of data copy loss, based on which an improved cost-efficient replica deployment strategy named ICERD is given. Finally, by simulating the random occurrence of cloud node failures in the experiments and comparing the ICERD strategy with representative strategies, it has been validated that the ICERD strategy proposed in this paper not only effectively reduces customer access latency, meets customers' QoS requests, and improves system service quality, but also maintains the load balancing of the entire system, reduces service cost, enhances system fault tolerance, which further confirm the effectiveness and reliability of the ICERD strategy.

Measurement of Transpiration Rate of Apple with a Microcomputer-Based Data Acquisition System during CA Storage (마이크로컴퓨터 시스템을 이용한 CA 저장 중 사과의 증산속도 측정)

  • 강준수;서명교
    • Food Science and Preservation
    • /
    • v.1 no.1
    • /
    • pp.37-43
    • /
    • 1994
  • A microcomputer system consisting of 16-bit microcomputer, PCL-711S interface board, censors, and converters have been set up in order to automatically measure temperature, humidity and weight loss which are major variables of storage of apple. This system was operated by PC-LabDAS software. It has been possible to measure continuously the weight loss of Fuji apple stored in CA with the weight converter made by a miniature load cell and a strain amplifier. The temperature was checked by a k-type thermocouple and Pt 100 $\Omega$ RTD, and humidity by PQ653JAl humidity sensor. It has been possible to set up a linear equation which showers high correlationship between the estimate of temperature, weight humidity and the output of the converter in that r2 is more than 0.99. Transpiration rate, a significant factor of quality deterioration for CA storage of apple, can be estimated with these values.

  • PDF

A Study on Influence of Synchronous Rectification Switch on Efficiency in Totem Pole Bridgeless PFC (토템폴 브리지리스 PFC에서 동기정류 스위치의 효율 영향에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.108-113
    • /
    • 2021
  • In this paper, a totem pole PFC was structured in two methods with FET and diode for low-speed switch while GaN FET was used for high-speed switch. Internal power loss, power conversion efficiency and steady-state characteristics of the two methods were compared in the totem pole bridgeless PFC circuit which is widely applied in large-capacity and high-efficiency switching rectifier of 500W or more. In order to compare and confirm the steady-state characteristics under equal conditions, a 2kW class totem pole bridgeless PFC was constructed and the experimental results were analyzed. From the experimental results, it was confirmed that the low-speed switch operation has a large difference in efficiency due to the internal conduction loss of the low-speed switch at a low input voltage. Especially, input power factor and load characteristic showed no difference regardless of the low-speed switch operation.

A Study on Application for Y-Tz Transformer Winding Method to Decrease the Current Unbalance on the Source Side (전원측 전류불평형 감소를 위한 변압기 Y-Tz 결선방식 적용에 관한 연구)

  • Lee, Jung-Eun;Song, Young-Joo;Choi, Hong-Kyoo;Kim, Tae-Hoon;Kim, In-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1206-1211
    • /
    • 2014
  • Most LV customers have been applying three-phase four-wire electric distribution system which supplies 1-phase and 3-phase load concurrently. Due to its structural simplicity, This system is easy to run. But it can also cause many problems from the unbalance, such as reduced output, increased loss etc. Also the unbalance in the load side causes the unbalance in the source side; it may lower the stability of the whole power system. In this paper, we propose the Y-Tz transformer winding method to reduce the current unbalance in the source side. Efficiency of this method was proven through the simulation and verification experiment.

Wear Loss Presumption of Motorcycle Disk Brake Using Design of Experiment (실험계획법에 의한 이륜자동차 브레이크 디스크의 마멸량 예측)

  • Park, Gyu-Jung;Park, Heung-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.4
    • /
    • pp.15-21
    • /
    • 2007
  • The effect of manufacturing parameters on friction characteristics of motorcycle break system was studied using a disk-on-pad type friction tester. Such parameters conditions have an effect on the frictional factor such as number of ventilated disk hole, applied load, sliding speed, and sliding distance. However, it is difficult to know the mutual relation of these factors. In this study, the friction characteristics using design of experiment containing 4 elements were investigated for an optimal condition for the best motorcycle break system employing regression analysis method. From this study, the result was shown that the applied load in frictional factors was the most important, next to sliding speed, number of ventilated disk hole.

  • PDF