• Title/Summary/Keyword: Loss and damage

Search Result 1,702, Processing Time 0.03 seconds

Web based evaluation of earthquake damages for reinforced concrete buildings

  • Isik, Ercan;Isik, Mehmet F.;Bulbul, Mehmet A.
    • Earthquakes and Structures
    • /
    • v.13 no.4
    • /
    • pp.387-396
    • /
    • 2017
  • The first determination and assessment of the damages to structures after the earthquake is important for preventing increase in loss of life and property that may occur in later times. When rapid damage assessment is performed after an earthquake, damage assessment forms are generally used. The forms that are filled in the field are assessed in the office environment later. In this study, while the process of earthquake damage assessment was being carried out, the ready-made form was moved to web base and the data to be obtained in the field was transferred to the database by means of tablets and smart phones. Keeping earthquake damages in a database will contribute to the studies to be conducted on earthquake and the earthquake regulations to be prepared. Furthermore, emergency damage assessment will be performed faster and more reliably after the earthquake through this study. As the data transferred to the web base is accessible to different people, savings will be provided for both time and personnel. Furthermore, the assessment will have a healthier and scientific basis. In this study, exemplification was conducted for six different reinforced concrete buildings that were damaged during Van earthquake in October 23. With this study, damage assessment procedures can be completed as soon as possible.

A Review on the Determination of the Protecting Duration of Frost Damage at Early Ages in Cold Weater Concreting Based on the Analysis of Strength Development (강도증진해석에 의한 한중콘크리트의 초기동해 방지기간 설정에 관한 검토)

  • 한민철;김효구;황인성;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.179-182
    • /
    • 1999
  • A protections from the frost damage at early ages is one of the serious problems to be considered in cold weather concreting. Frost damage at early ages brings about the harmful influences on the concrete structures such surface cracks and the loss of strength. Therefore, in this paper, the protecting durations of frost damage at early ages according to the standard specifications provided in KCI(Korean Concrete Institute) are suggested by appling logistic curve, which evaluates the strength development of concrete with maturity. According to the results, as W/C and compressive strength for protecting from frost damages at early ages increased, longer protecting duration is required. It shows that the protecting durations of FAC(Fly Ash Cement) are longer than those of OPC(Ordinary Portland Cement).

  • PDF

Laboratory Simulation of Corrosion Damage in Reinforced Concrete

  • Altoubat, S.;Maalej, M.;Shaikh, F.U.A.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.3
    • /
    • pp.383-391
    • /
    • 2016
  • This paper reports the results of an experimental program involving several small-scale columns which were constructed to simulate corrosion damage in the field using two accelerated corrosion techniques namely, constant voltage and constant current. A total of six columns were cast for this experiment. For one pair of regular RC columns, corrosion was accelerated using constant voltage and for another pair, corrosion was accelerated using constant current. The remaining pair of regular RC columns was used as control. In the experiment, all the columns were subjected to cyclic wetting and drying using sodium chloride (NaCl) solution. The currents were monitored on an hourly interval and cracks were visually checked throughout the test program. After the specimens had suffered sufficient percentage steel loss, all the columns including the control were tested to failure in compression. The test results generated show that accelerated corrosion using impressed constant current produces more corrosion damage than that using constant voltage. The results suggest that the constant current approach can be better used to simulate corrosion damage of reinforced concrete structures and to assess the effectiveness of various materials, repair strategies and admixtures to resist corrosion damage.

Effect of Flow Rate on Erosion Corrosion Damage and Damage Mechanism of Al5083-H321 Aluminum Alloy in Seawater Environment (해수 환경에서 Al5083-H321 알루미늄 합금의 침식부식 손상에 미치는 유속의 영향과 손상 메카니즘)

  • Kim, Young-Bok;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.115-121
    • /
    • 2020
  • In this study, erosion tests and erosion-corrosion tests of Al5083-H321 aluminum alloy were conducted at various flow rates in seawater. The erosion tests were conducted at a flow rate of 0 to 20 m/s, and erosion-corrosion tests were performed by potentiodynamic polarization method at the same flow rate. Characteristic evaluation after the erosion test was conducted by surface analysis. Characteristic evaluation after the erosion-corrosion test was performed by Tafel extrapolation and surface analysis. The results of the surface analysis after the erosion test showed that surface damage tended to increase as the flow rate increased. In particular, intermetallic particles were separated due to the breakdown of the oxide film at 10 m/s or more. In the erosion-corrosion test, the corrosion current density increased as the flow rate increased. Additionally, the surface analysis showed that surface damage occurred in a vortex shape and the width of the surface damage tended to increase as the flow rate increased. Moreover, damage at 0 m/s, proceeded in a depth direction due to the growth of pitting corrosion, and the damaged area tended to increase due to acceleration of the intermetallic particle loss by the fluid impact.

GIS-based Slope Damage Assessment of Highways During Heavy Rainfalls (집중호우시 GIS를 이용한 고속도로 사면붕괴 영향평가)

  • Jeon, Sang-Soo;Yun, Hong-Sik;Lee, Dong-Ha;Kim, Doo-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.191-198
    • /
    • 2005
  • Slope failures during heavy rainfall have resulted in death of life and economic loss. In recent years, the research on slope damage assessment using Geographical Information System(GIS) has been actively carried out by researchers of several goverment organizations and schools. The researchers in Highway and Transportation Technology Institute (HTTI) of Korea Highway Corporation has developed the GIS database(DB), including highway, rainfalls, soil or rock geometry, types of damage, etc. and have been working on the damage assessment of highway slopes. The DB has been established and summarized in two different ways, such as highway routes and administrative districts. Grid of rainfall intensity generated by maximum rainfalls of each administrative district has been devloped. It shows good correlation of slope damage with heavy rainfalls. Most of damaged slopes were found in the amount of 100 mm to 300 mm rainfalls.

  • PDF

Root resorption

  • Kwon, Anne-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.243-244
    • /
    • 2001
  • Root resorption is conventionally divided into internal and external varieties. Internal resorption occurs where there is loss of the internal wall of the root canal. and is usually associated with a localized area of necrotic pulp(Trope '||'&'||' Chivian 1984). External resorption occurs where there is loss of the external surface of the root and the resorption may be either transient or progressive(Tronstad 1988). External inflammatory resorption usually occurs following damage to the periodontal ligament or where there is communication between the periodontal ligament and a necrotic pulp. via open dentinal tubules or accessory canals. This type of resorption is usually progressive until root canal treatment is instituted (Barclay 1993).

  • PDF

Structure damage estimation due to tunnel excavation based on indoor model test

  • Nam, Kyoungmin;Kim, Jungjoo;Kwak, Dongyoup;Rehman, Hafeezur;Yoo, Hankyu
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.95-102
    • /
    • 2020
  • Population concentration in urban areas has led traffic management a central issue. To mitigate traffic congestions, the government has planned to construct large-cross-section tunnels deep underground. This study focuses on estimating the damage caused to frame structures owing to tunnel excavation. When constructing a tunnel network deep underground, it is necessary to divide the main tunnel and connect the divergence tunnel to the ground surface. Ground settlement is caused by excavation of the adjacent divergence tunnel. Therefore, predicting ground settlement using diverse variables is necessary before performing damage estimation. We used the volume loss and cover-tunnel diameter ratio as the variables in this study. Applying the ground settlement values to the settlement induction device, we measured the extent of damage to frame structures due to displacement at specific points. The vertical and horizontal displacements that occur at these points were measured using preattached LVDT (Linear variable differential transformer), and the lateral strain and angular distortion were calculated using these displacements. The lateral strain and angular distortion are key parameters for structural damage estimation. A damage assessment chart comprises the "Negligible", "Very Slight Damage", "Slight Damage", "Moderate to Severe Damage", and "Severe to Very Severe Damage" categories was developed. This table was applied to steel frame and concrete frame structures for comparison.

Method of Optimum Efficiency to Coefficient of Utilization for Single Phase Induction Motor (단상 유도전동기의 이용률 변동에 대한 최적효율 산정기법)

  • Kim, Yang-Ho;Kim, Young-Sun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.155-160
    • /
    • 2006
  • In this paper, deduced suitable optimization to request output condition after taking closely characteristic data of single phase induction motor(SIM) which is the possibility becoming economic is coming to be demanded. Motor proper move connection data took advantage of result of existing data and iron loss and copper loss, mechanical loss took advantage of statistical data, and decide motor move laking advantage of saving data and secondary resistance and optimum purpose of method that is proposed through single phase induction motor and comparison performance evaluation having on the same output parameter. That decide material factor, electric power damage ratio, and coefficient of utilization for optimum function by method that search request output and optimum values of efficiency case by case and decided is proper that is saved after take magnetizing reactance relationship. This research result which it sees against a material expense with use coefficient of utilization which is included in loss expense decides the same plan variable back the place efficiency is useful and will be applied.

Changes of modal properties of simply-supported plane beams due to damages

  • Xiang, Zhihai;Zhang, Yao
    • Interaction and multiscale mechanics
    • /
    • v.2 no.2
    • /
    • pp.153-175
    • /
    • 2009
  • Damage detection methods using structural dynamic responses have received much attention in the past decades. For bridge and offshore structures, these methods are usually based on beam models. To ensure the successful application of these methods, it is necessary to examine the sensitivity of modal properties to structural damages. To this end, an analytic solution is presented of the modal properties of simply-supported Euler-Bernoulli beams that contain a general damage with no additional assumptions. The damage can be a reduction in the bending stiffness or a loss of mass within a beam segment. This solution enables us to thoroughly discuss the sensitivities of different modal properties to various damages. It is observed that the lower natural frequencies and mode shapes do not change so much when a section of the beam is damaged, while the mode of rotation angle and curvature modes show abrupt change near the damaged region. Although similar observations have been reported previously, the analytical solution presented herein for clarifying the mechanism involved is considered a contribution to the literature. It is helpful for developing new damage detection methods for structures of the beam type.

Biological Assessment of Blasting Noise and Vibration in Residential Area: I. Damage of Residents and Dogs

  • Choi, Won-Chul;Seo, Seok-Jin;Son, Joo-Young
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.2
    • /
    • pp.123-133
    • /
    • 1998
  • As the results of investigation, the noise level was between 60 dB and 80 dB in the area of explosion. The residents living within 1 Km would feel uncomfortable. However, hearing loss is not happened by this range. The maximum range that the human can hear is 20,000 Hz and the maximum range that the dog can hear is between 20 Hz and 40,000 Hz. The auditory range for humans to be uncomfortable toward noise is between 1,000 Hz and 2,000 Hz. As the result of this experiment, the auditory range of dog is more wide than of a human. The change of hair cells in the Corti's organ occurred when the dog was exposed to 1,000 Hz at 100 dB for 1 month. Therefore, the structure change of the ear could happen by hearing loss because of noise, but the structure change of hair cells is the worst symptom by hearing loss because of noise.

  • PDF