• 제목/요약/키워드: Loss analysis

검색결과 8,478건 처리시간 0.043초

무효전력 손실감도를 이용한 정적 전압 안정도 해석 (Static Voltage Stability Analysis using Reactive Power Loss Sensitivity)

  • 김원겸;이복용;이상철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.52-55
    • /
    • 1999
  • In recent years, much attention has been paid to the voltage collapse phenomena. There has been reported many cases about the voltage collapse in many countries. These voltage collapse phenomena are known as the event that can occur due to reactive power deficits. This paper proposes an efficient method that can pursue the reactive power loss changes and gives the simple voltage collapse proximity indicator(VCPI) based on the reactive power loss sensitivities using optimal techniques. By comparing reactive power loss sensitivity with active power loss sensitivity, it is also proved that VCPI based on reactive power loss sensitivities is more effective. The developed VCPI is derived from the Jacobian matrix of Load Flow and the computational burden is very low and on-line implementation is possible. The proposed method is applied to a IEEE-14 bus test system and reliable and promising results are obtained.

  • PDF

Analytical Study Considering Both Core Loss Resistance and Magnetic Cross Saturation of Interior Permanent Magnet Synchronous Motors

  • Kim, Young-Kyoun
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.280-284
    • /
    • 2012
  • This paper presents a method for evaluating interior permanent magnet synchronous motor (IPMSM) performance over the entire operation region. Using a d-q axis equivalent circuit model consisting of motor parameters such as the permanent magnetic flux, copper resistance, core loss resistance, and d-q axis inductance, a conventional mathematical model of an IPMSM has been developed. It is well understood that in IPMSMs, magnetic operating conditions cause cross saturation and that the iron loss resistance - upon which core losses depend - changes according to the motor speed; for the sake of convenience, however, d-q axis machine models usually neglect the influence of magnetic cross saturation and assume that the iron loss resistance is constant. This paper proposes an analysis method based on considering a magnetic cross saturation and estimating a core loss resistance that changes with the operating conditions and speed. The proposed method is then verified by means of a comparison between the computed and the experimental results.

스위치 손실 감소를 위한 단상 3레벨 NPC 인버터의 새로운 스위칭 방법 (A New Switching Method for Reducing switch loss of Single-phase three-level NPC inverter)

  • 이승주;이준석;이교범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.268-275
    • /
    • 2015
  • This paper proposes a method of switching to improve power loss for the single-phase three-level NPC inverter. The conventional switching methods, which are called as the bipolar and unipolar switching methods, are used for single phase inverters using three-level topology. However, these switching method have disadvantage in the power loss. Because all of the switch are operated. To reduce the power loss of the three-level NPC inverter, clamp switching method is introduced in this paper. This way, one of the lag is fixed that switching loss is reduced. This paper analyzes and compares power losses of unipolar method and clamp method. The validity of the power loss analysis is verified through the simulation and experimental results.

In-situ 소음투과손실 측정 및 검증을 위한 기법 개발 (New Method for Measurement and Validation of In-situ Sound Transmission Loss)

  • 이화수;박홍철;윤성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

사다리꼴 fin: 사각 fin과의 열손실 비교와 열손실에 미치는 경사요소의 효과 (Trapezoidal Fin : Comparison of Heat Loss with Rectangular Fin and the Effect of Slope Factor on the Heat Loss)

  • 강형석;윤세창
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.33-40
    • /
    • 2001
  • Heat loss from the trapezoidal fins haying different upper side slope and that from a rectangular fin are investigated by the three dimensional analytic method. It is shown that the trapezoidal fins having different upper side slope become an approximate rectangular fin by inst adjusting the slope factor. The comparison of the heat loss between a rectangular fin and an approximate rectangular fin is represented as a function of the non-dimensional fin length, fin width and Biot number to make sure that the analysis on the trapezoidal fins having different upper side slope is countable. One of the results is that the relative value of heat loss between a rectangular fin and an approximate rectangular fin is less than 1.5% for given ranges of non-dimensional length and width in case of Bi = 0.1.

  • PDF

Opposition Based Differential Evolution Algorithm for Capacitor Placement on Radial Distribution System

  • Muthukumar, R.;Thanushkodi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.45-51
    • /
    • 2014
  • Distribution system is a critical link between customer and utility. The control of power loss is the main factor which decides the performance of the distribution system. There are two methods such as (i) distribution system reconfiguration and (ii) inclusion of capacitor banks, used for controlling the real power loss. Considering the improvement in voltage profile with the power loss reduction, later method produces better performance than former method. This paper presents an advanced evolutionary algorithm for capacitor inclusion for loss reduction. The conventional sensitivity analysis is used to find the optimal location for the capacitors. In order to achieve a better approximation for the current candidate solution, Opposition based Differential Evolution (ODE) is introduced. The effectiveness of the proposed technique is validated through 10, 33, 34 and85-bus radial distribution systems.

IMF 초기 2년간 흑자/적자병원의 재무구조와 경영성과분석 (Analysis of Financial Structure and Managerial Performance of Profit/Loss-Making Hospitals under the IMF)

  • 이창은;정기선;황인경
    • 한국병원경영학회지
    • /
    • 제6권2호
    • /
    • pp.156-172
    • /
    • 2001
  • Financial ratio indicators of the 73 sample hospitals provided by the Korea Hospital Association in 1998-1999, together with the data by the Korea Health Industry Development Institute in 1007, were analysed to identify the financial structure and managerial performance of the profit/loss-making hospitals under the IMF. The major findings of this study were as belows. 1. Among the general characteristics, there was a statistical significance in the hospital location and the number of operating beds between profit-making hospitals and loss-making hospitals. 2. Financial ratio indicators of the profit-making hospitals were better than those of the loss-making hospitals. 3. Financial ratio indicators, including Liquidity, Performance Indicators and Growth Rate Indicators of profit-making hospitals, were better than those of loss-making hospitals except for Turnover Ratios under the IMF economic impasse.

  • PDF

원형으로 굽은 광도파로의 low bending loss를 위한 trench 구조설계: 원통좌표계 FD-BPM (A Trench Structure for Low Bending Loss of Bent Optical Waveguides)

  • 한영진;김창민
    • 한국광학회지
    • /
    • 제6권4호
    • /
    • pp.373-378
    • /
    • 1995
  • 원통좌표계에서의 FD-BPM(finite difference-beam propagation method)을 이용하여 굽은 광도파로의 bending loss를 계산하였다. Bending loss를 최소화하기 위해 trench구조를 적용하였으며 다음의 세가지 측면에서 해석하였다. 1)trench구조가 없을때 곡률반경에 따른 bending loss, 2)폭과 위치가 일정한 trench구조가 있을때 곡률반경과 굴절율차에 따른 bending loss, 3)trench의 위치가 일정할 때 trench의 폭에 따른 bending loss를 계산하였다.

  • PDF

송전손실을 고려한 온라인 경제급전 알고리즘 (On-Line Economic Dispatch Algorithm including Transmission Loss)

  • 전동훈;김건중;최장흠;장경철;임종호;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.847-849
    • /
    • 1998
  • In this paper, we propose the generalized on-line economic dispatch algorithm including transmission loss. it was derived from the process developing matrix form of the classic ELD problem. it can rapidly calculate generation power using transmission loss and transmission loss sensitivity calculated from the result of power flow analysis. Transmission loss sensitivity ${\partial}P_{loss}/{\partial}P_G$ is derived using optimization technique.

  • PDF

Parameter Optimal Choice of Claw Pole Alternator based on Iron Loss Model

  • Bao, Xiaohua;Wei, Qiong;Wu, Feng;Li, Jiaqing
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.260-268
    • /
    • 2013
  • Based on classical Berotti discrete iron loss calculation model, the iron loss analysis mathematical model of alternator was proposed in this paper. Considering characteristics of high speed and changing frequency of the alternator, Maxwell 3-D model was built to analyze iron loss corresponding to each running speed in alternator. Based on iron loss model of alternator at rated speed, the rotor claw pole size was made an optimization design. The optimization results showed that alternator's output performance had been improved. A new idea was explored in size optimization design of claw pole alternator.