• Title/Summary/Keyword: Loss Sensitivity

Search Result 544, Processing Time 0.027 seconds

A Study on the System Loss Minimizing Algorithm by Optimal Re-location of Static Condenser Using System Power Loss Sensitivity (계통손실 감소를 위한 전력용 콘덴서의 適正 再配置에 대한 연구)

  • 이상중;김건중;정태호;김원겸;김용배
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.1
    • /
    • pp.21-24
    • /
    • 1995
  • The larger and the more complicated the system size and configuration grow, the more serious the system loss problem becomes. Exessive system loss causes severs system voltage depression, which even may result in system voltage collapse. This paper proposes an effective tool for minimizing the system power loss by optimal re-location of the static condenser based on the system loss sensitivity index .lambda.$_{Q}$. It is possible to determine the optimal location and amount of VAR investment for minimizing the system loss by priority of .lambda.$_{Q}$ index given for each bus. Several computational techniques for avoiding divergency of the load flow solution are proposed. The loss sensitivity index .lambda.$_{Q}$ uses information of normal power flow equations and their Jacobians. Two case studies proved the effectiveness of the algorithm proposed.posed.

  • PDF

Differential Diagnosis on the Types of Hearing Loss using Short Increment Sensitivity Index(SISI) Test and Bekesy Audiometry (미세증가감수지수검사와 자기청력검사를 이용한 난청 유형의 감별 진단)

  • Kim, Jin-Dong;Jeon, Gye-Rok;Wang, Soo-Geon;Shin, Bum-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.704-713
    • /
    • 2009
  • As using recruitment phenomenon, SISI test and Bekesy audiometry are employed to differentially diagnose both the cochlear hearing loss and the retrocochlear hearing loss. The main purpose of this study is to find out the sensitivity and specificity of the SISI test within the scope of 1 KHz to 4 KHz in diagnosing various types of hearing losses. In this study, the Bekesy audiometry was conducted for Bekesy audiograms of certain groups according to Jerger's classification, which included persons with normal hearing and patients with hearing impairment. Subject persons of the SISI test were categorized into the several groups with normal hearing, mild hearing loss, moderate hearing loss, moderate-severe hearing loss and severe hearing loss, respectively. The sensitivity and specificity of certain groups were evaluated according to the SISI scores of 20 % below, 25 ${\sim}$ 65 %, and more than 70%. Also, the Bekesy audiometry is conducted on the several subject groups with normal hearing, mixed hearing loss, and sensori-neural hearing loss.

Applications of System Loss Sensitivity Index to Power Systems (손실감도지표의 전력계통 적용)

  • Lee, Sang-Jung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.56-61
    • /
    • 2000
  • In the paper, the system loss sensitivity index that implies the incremental system loss with respect to the change of bus power is derived using optimization technique. The index λ reaches $\infty$ at critical loading point and can be applied to actual power systems for following purposes. 1) Evaluation of system voltage stability 2)Optimal investment of reactive power focused on minimizing system loss and maximizing system voltage stability 3)Optimal re-location of reactive power focused on minimizing system loss and maximizing system voltage stability 4)Optimal load shedding in case of severe system contingency focused on minimizing system loss and maximizing system voltage stability. Case studies for each application have proved their effectiveness.

  • PDF

An Initial Synchronization Method to Enhance Receive Sensitivity of the GPS Receiver for Reference Stations (기준국용 GPS 수신기의 수신감도 향상을 위한 초기동기 방법)

  • Park Sang-Hyun;Shin Jae-Ho;Park Jeong-Yeol
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.235-240
    • /
    • 2006
  • In order to enhance receive sensitivity in noisy environment, the previous initial synchronization method of GPS receiver for reference stations adopts not only the coherent integration method but also the non-coherent integration method. However, the previous GPS initial synchronization method causes the non-coherent integration loss, which is a dominant factor among the signal acquisition losses in noisy environment. And the non-coherent integration loss increases with the strength of noise signal. In this pa-per, a GPS initial synchronization method is proposed to enhance receive sensitivity of GPS receiver for reference stations in noisy environment. This paper presents that the proposed GPS initial synchronization method suppresses the non-coherent integration loss. Furthermore, with regard to the mean acquisition time, it is shown that the number of the search cells of the proposed GPS initial synchronization method is much fewer than that of the previous GPS initial synchronization method.

  • PDF

Static Voltage Stability Analysis using Reactive Power Loss Sensitivity (무효전력 손실감도를 이용한 정적 전압 안정도 해석)

  • Kim, Weon-Kyum;Lee, Bok-Yong;Lee, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.52-55
    • /
    • 1999
  • In recent years, much attention has been paid to the voltage collapse phenomena. There has been reported many cases about the voltage collapse in many countries. These voltage collapse phenomena are known as the event that can occur due to reactive power deficits. This paper proposes an efficient method that can pursue the reactive power loss changes and gives the simple voltage collapse proximity indicator(VCPI) based on the reactive power loss sensitivities using optimal techniques. By comparing reactive power loss sensitivity with active power loss sensitivity, it is also proved that VCPI based on reactive power loss sensitivities is more effective. The developed VCPI is derived from the Jacobian matrix of Load Flow and the computational burden is very low and on-line implementation is possible. The proposed method is applied to a IEEE-14 bus test system and reliable and promising results are obtained.

  • PDF

Path-dependency of Transmission Loss Allocation using Transaction Strategy (거래전략에 따른 송전손실배분의 경로의존성에 관한 연구)

  • Min, Kyung-Il;Ha, Sang-Hyeon;Lee, Su-Won;Moon, Young-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.924-931
    • /
    • 2008
  • This paper presents a buswise transmission loss allocation algorithm utilizing the transaction strategy. We prove that whatever calculated by any transaction strategy, the total of the allocated transmission losses of each bus, including no-load loss allocation, almost equals the total loss of AC power flow algorithm and the loss is perfectly slackbus-independent. In this paper, the allocated transmission losses of each bus is calculated by the method of integrating loss sensitivities using by the load level parameter ${\lambda}$. The performance of the proposed algorithm is evaluated by the case studies carried out on the WSCC 9-bus and IEEE 14-bus systems.

Accurate Transmission Loss Allocation Algorithm Based on the Virtual Transaction Strategy: Comparison of Path-integral with Discrete Integral Methods

  • Min, Kyung-Il;Moon, Young-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.511-521
    • /
    • 2010
  • This paper presents a new algorithm to determine accurate bus-wise transmission loss allocation utilizing path-integrals dictated by the transaction strategy. For any transaction strategy, the total sum of the allocated transmission losses of all buses is equal to the actual loss given by the AC power-flow calculation considering the distributed slack. In this paper, the bus-wise allocation of the transmission loss is calculated by integrating the differential loss along a path determined by the transaction strategy. The proposed algorithm is also compared with Galiana's method, which is the well-known transmission loss allocation algorithm based on integration. The performance of the proposed algorithm is evaluated by case studies carried out on the WSCC 9-bus, IEEE 14-bus, New England 39-bus, and IEEE 118-bus systems. The simulation results show that the proposed algorithm is fast and accurate with a large step size.

Voltage collapse proximity index based on system apparent power loss sensitivity and its application to VAR investment (피상전력 손실감도에 의한 전압붕괴 근접도 지표와 무효전력 투자)

  • 이상중;김건중;김원겸;김용배;엄재선
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.10
    • /
    • pp.1290-1294
    • /
    • 1995
  • In this paper, a new voltage collapse proximity index (VCPI) based on system apparent power loss sensitivity is proposed. The newly proposed index .lambda.$^{Sloss}$ reaches -.inf. at system voltage collapse point and can be represented by .root..lambda.$^{Ploss}$$^{2}$+.lambda.$^{Qloss}$$^{2}$ where .lambda.$^{Ploss}$ and .lambda.$^{Qloss}$ are the VCPI based on the system active and reactive power loss sensitivity respectively. These indices can be used for the system VAR investment. .DELTA.Q [VAR] is invested, step by step, by the priority of the VCPI index given for each bus. The indices use information from normal power flow equations and their Jacobians. Computation time for deriving .lambda.$^{Sloss}$ is almost same as that for power flow calculation. Two case studies prove the effectiveness of the .lambda.$^{Sloss}$ index and the VAR investment algorithm proposed.

  • PDF

Rate of softening and sensitivity for weakly cemented sensitive clays

  • Park, DongSoon
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.827-836
    • /
    • 2016
  • The rate of softening is an important factor to determine whether the failure occurs along localized shear band or in a more diffused manner. In this paper, strength loss and softening rate effect depending on sensitivity are investigated for weakly cemented clays, for both artificially cemented high plasticity San Francisco Bay Mud and low plasticity Yolo Loam. Destructuration and softening behavior for weakly cemented sensitive clays are demonstrated and discussed through multiple vane shear tests. Artificial sensitive clays are prepared in the laboratory for physical modeling or constitutive modeling using a small amount of cement (2 to 5%) with controlled initial water content and curing period. Through test results, shear band thickness is theoretically computed and the rate of softening is represented as a newly introduced parameter, ${\omega}_{80%}$. Consequently, it is found that the softening rate increases with sensitivity for weakly cemented sensitive clays. Increased softening rate represents faster strength loss to residual state and faster minimizing of shear band thickness. Uncemented clay has very low softening rate to 80% strength drop. Also, it is found that higher brittleness index ($I_b$) relatively shows faster softening rate. The result would be beneficial to study of physical modeling for sensitive clays in that artificially constructed high sensitivity (up to $S_t=23$) clay exhibits faster strain softening, which results in localized shear band failure once it is remolded.

Opposition Based Differential Evolution Algorithm for Capacitor Placement on Radial Distribution System

  • Muthukumar, R.;Thanushkodi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2014
  • Distribution system is a critical link between customer and utility. The control of power loss is the main factor which decides the performance of the distribution system. There are two methods such as (i) distribution system reconfiguration and (ii) inclusion of capacitor banks, used for controlling the real power loss. Considering the improvement in voltage profile with the power loss reduction, later method produces better performance than former method. This paper presents an advanced evolutionary algorithm for capacitor inclusion for loss reduction. The conventional sensitivity analysis is used to find the optimal location for the capacitors. In order to achieve a better approximation for the current candidate solution, Opposition based Differential Evolution (ODE) is introduced. The effectiveness of the proposed technique is validated through 10, 33, 34 and85-bus radial distribution systems.