• 제목/요약/키워드: Loss Estimation

Search Result 1,098, Processing Time 0.032 seconds

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

Insights from existing earthquake loss assessment research in Croatia

  • Hadzima-Nyarko, Marijana;Sipos, Tanja Kalman
    • Earthquakes and Structures
    • /
    • v.13 no.4
    • /
    • pp.365-375
    • /
    • 2017
  • Seismic risk management has two main technical aspects: to recommend the construction of high-performance buildings and other structures using earthquake-resistant designs or evaluate existing ones, and to prepare emergency plans using realistic seismic scenarios. An overview of seismic risk assessment methodologies in Croatia is provided with details regarding the components of the assessment procedures: hazard, vulnerability and exposure. For Croatia, hazard is presented with two maps and it is expressed in terms of the peak horizontal ground acceleration during an earthquake, with the return period of 95 or 475 years. A standard building typology catalogue for Croatia has not been prepared yet, but a database for the fourth largest city in Croatia is currently in its initial stage. Two methods for earthquake vulnerability assessment are applied and compared. The first is a relatively simple and fast analysis of potential seismic vulnerability proposed by Croatian researchers using damage index (DI) as a numerical value indicating the level of structural damage, while the second is the Macroseismic method.

Integrated Model for Assessment of Risks in Rail Tracks under Various Operating Conditions

  • G. Chattopadhyay;V. Reddy;Larsson, P-O
    • International Journal of Reliability and Applications
    • /
    • v.4 no.4
    • /
    • pp.183-190
    • /
    • 2003
  • Rail breaks and derailments can cause a huge loss to rail players due to loss of service, revenue, property or even life. Maintenance has huge impact on reliability and safety of railroads. It is important to identify factors behind rail degradation and their risks associated with rail breaks and derailments. Development of mathematical models is essential for prediction and prevention of risks due to rail and wheel set damages, rail breaks and derailments. This paper addresses identification of hazard modes, estimation of probability of those hazards under operating, curve and environmental condition, probability of detection of potential hazards before happening and severity of those hazards for informed strategic decisions. Emphasis is put on optimal maintenance and operational decisions. Real life data is used for illustration.

  • PDF

The prediction of train interior noise with Statistical Energy Analysis (통계적 에너지 해석법을 이용한 전동차의 실내소음 분석)

  • Lee, Seoung-Woo;Kim, Jae-Chul;Lee, Dong-Hoon;Choo, Don-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1413-1419
    • /
    • 2008
  • As the improvements of service quality is becoming an important issue the, interior noise level of a train is an important factor of comfortable ride. To reduce the interior noise level, noise sources of the train need to be removed. However, in case with a structure of large scale and multiple noise sources, an estimation of influences of major noise sources, with indentification of its traveling paths needs to be performed. In current state, to improve the interior noise reduction, consideration of sound transmission loss of the train body prior to manufacturing is usually performed. In this study, the sound transmission loss of the train body of new model train of seoul metro's line no.2 under test opeation is measured and modeling of the train body is performed. And train interior noise is predicted using the measured values.

  • PDF

Estimation of Head Loss Coefficient Empirical Formulas Using Model Experimental Results in a 90° Angle Dividing Channel Junction (90도 각도를 갖는 분기수로에서 모형실험결과를 이용한 손실계수 경험식 산정)

  • Park, Inhwan;Seong, Hoje;Kim, Hyung-Jun;Rhee, Dong Sop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.989-999
    • /
    • 2017
  • In this study, hydraulic experimental studies were conducted to estimate the empirical formulas of loss coefficient, which is necessary to calculate the energy loss occurred in the dividing channel junction of sewer system. The experimental apparatus was consisted of two outflow conduit with a $90^{\circ}$ angle to the inlet conduit, and the pressure and velocity heads are measured to analyze the energy losses in the branch. The measurements of the hydraulic grade line show that the hydraulic grade line was steeply descended at the dividing point due to the head loss, and the decreasing amount of velocity head increased with the increase of flowrate ratio. The head loss exponentially increased in the outlet with larger runoff as the increase of flowrate ratio and Froude number, and the head loss coefficient also increased. On the other hands, the head loss coefficients decreased in the outlet with smaller runoff as the increase of the flowrate ratio and Froude number. Using the experimental results, the empirical formulas of loss coefficient was suggested for each outlet, and the error of empirical formula was 3.91 and 5.19%, respectively. Furthermore, the total head loss coefficient calculated by the two empirical formulas was compared with the experimental results, and the error was 3.62%.

An Experimental Study for Estimation of Head Loss Coefficients at Surcharged Circular Manhole (과부하 원형맨홀에서의 손실계수 산정을 위한 실험적 연구)

  • Kim, Jung-Soo;Song, Ju-Il;Jang, Suk-Jin;Yoon, Sei-Eui
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.3
    • /
    • pp.305-314
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at circular manholes are usually not significant. However, the energy loss at manholes, often exceeding the friction loss of pipes under surcharge flow, is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharge flow. Hydraulic experimental apparatus which can be changed the invert type(CASE A, B, C) and step height(CASE I, II, III) was installed for this study. The range of the experimental discharges were from $1.0{\ell}/sec$ to $5.6\;{\ell}/sec$. As the manhole diameter ratio($D_m/D_{in}$) increases, head loss coefficient increases due to strong horizontal swirl motion. Head loss coefficient was maximum because of strong oscillation of water surface when the range of manhole depth ratios($h_m/D_{in}$) were from 1.0 to 1.5. The average head loss coefficients for CASE A, B, and C were 0.45, 0.37, and 0.30, respectively. Accordingly, U-invert is most effective for energy loss reduction at circular manhole. This head loss coefficients could be available to design the urban sewer system with surcharge flow.

Development of Estimation Equations for Solid Deposition in Sewer Systems (관거 내 고형물 퇴적량 산정식 개발)

  • Lee, Jae-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.5
    • /
    • pp.409-418
    • /
    • 2007
  • Combined sewer solid deposition during dry weather periods and their resuspension during wet weather periods has long been recognized as a major contributor to the first-flush phenomenon. Also, these deposition of sewer solids results in a loss of flow capacity that may restrict flow and cause a local flooding at urban area. In order to solve these problems, measurement of solid deposition for a given sewer system for extended period is needed but this task is very difficult and extremely expensive. This paper presents the development and applicability of estimation equations for solid deposition in sewer systems based on the solid deposition estimated using MOUSE model. As results, the comparison between estimated and measured solid deposition is difficult due to the absent of measured data, but the estimated values using developed equations show applicability compared with the results of MOUSE model and the estimation equations developed by the EPA.

Development of Estimation Equations for Solid Deposition in Sewer Systems due to Rainfall (강우로 인한 관거 내 고형물 퇴적량 산정식 개발)

  • Lee, Jae-Soo;Lee, Se-Won
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.885-894
    • /
    • 2008
  • The deposition of solids in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. In order to solve these problems and proper pipe management, estimations of solid loads on land surface in a drainage basin and solid deposition in sewer system due to rainfall are needed but these tasks are very difficult and very expensive. In this study, procedures for estimating solid loads on surface in a drainage basin were applied and analyzed in Gunja drainage basin in Korea. Also, this paper presents the development and application of estimation equation for solid deposition in sewer system due to rainfall based on the solid deposition estimated using MOUSE model. As results, the comparison between estimated and measured solid deposition is difficult due to the absent of measured data, but the estimated values using developed equations show applicability compared with the results of MOUSE model and the application of the other basin. The developed estimation equations can be used usefully for the management of combined sewer system.

Two-Part Tax for Polluting Oligopolists with Endogenous Entry (내생적 시장진입 구조에서 오염배출 과점기업에 대한 이부 환경세)

  • Park, Chul-Hi;Lee, Sang-Ho
    • Environmental and Resource Economics Review
    • /
    • v.19 no.3
    • /
    • pp.459-483
    • /
    • 2010
  • This paper constructs the two-part tax-a combined form of output tax and entrance fee-for polluting oligopolists under endogenous entry. In the presence of external damage that varies exogenously with aggregate output, we show that the two-part tax produces the ex post Pigouvian rule and thus achieves the first-best optimum. We also examine a detailed analysis of the impact of the two-part tax on social welfare and government revenues. Finally, when estimation errors exist in the process of regulation, we identify the incentive conflicts between interest groups and analyze the effects of estimation errors on determining optimal tax. In particular, we show that if the regulator takes care of both welfare loss and revenue gain under the proposed two-part tax, not only over-estimation on the slope of external damage but also under-estimation on the slope of market demand should be taken into the policy consideration.

  • PDF

Recommendation of I-D Criterion for Steep-Slope Failure Estimation Considering Rainfall Infiltration Mechanism (강우침투 메커니즘을 이용한 급경사지 붕괴예측 I-D 기준식 제안)

  • Song, Young-Karb;Kim, Young-Uk;Kim, Dong-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.65-74
    • /
    • 2013
  • The natural disaster occurrences and the loss of lives caused by the steep-slope failures in Korea were investigated in this study. The investigation includes the frequency rate of the steep-slope failures with respect to the characteristics of precipitation, underlying bedrock, and weathered soils. Analysis on the problems in the existing estimation methods of steep-slope failure was also undertaken, and a new model using unsaturated infinite slope stability was developed for the better slope failure estimation. The slope analyses by the newly developed model were performed considering unsaturated infinite slope, the gradient of slope, and hydro/mechanical properties of soils. Steep-slope failure estimation criterion is proposed based on the analysis results. In addition, the precipitation amount corresponding to warning stages against steep-slope failure is provided as an equation of Intensity-Duration criterion.