• Title/Summary/Keyword: Loop Type

Search Result 951, Processing Time 0.048 seconds

Resting cysts and vegetative cells of Pheopolykrikos hartmannii (W. Zimmermann) Matsuoka & Fukuyo(Dinophyceae): Morphology, phylogeny, and effect of temperature on germination (Pheopolykrikos hartmannii(W. Zimmermann) Matsuoka & Fukuyo 휴면포자와 유영세포: 형태적 특징 및 계통 분류, 발아에 미치는 온도 영향)

  • Kyeong Yoon Kwak;Joo Yeon Youn;Hyun Jung Kim;Kyong Ha Han;Zhun Li;Hyeon Ho Shin
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.387-397
    • /
    • 2022
  • The germination characteristics of the resting cysts of Pheopolykrikos hartmannii collected from the southern coastal sediments of Korea were studied at different temperature conditions, and the morphology and phylogeny of the germlings were examined. The resting cysts of Ph. hartmannii were round and characterized by a red accumulation body and many arrow-like spines and could germinate at temperature of 10 to 30℃. High germination rates (>90%) were observed at 15 and 20℃, indicating that the resting cysts could act as seed populations for the bloom initiation of Ph. hartmannii in Korean coastal waters in early summer or early fall. The morphology of the germlings was generally consistent with the previous description, and an apical groove characterized by a fully enclosed loop was observed. Phylogenetic analysis based on large SubUnit (LSU) rRNA gene sequences revealed that the germlings shared an identical sequence with the Korean and American isolates of Ph. hartmannii and was a sister clade of Polykrikos species.

The Immunological Position of Fibroblastic Reticular Cells Derived From Lymph Node Stroma (림프절 스트로마 유래 Fibroblastic Reticular Cell의 면역학적 위치)

  • Jong-Hwan Lee
    • Journal of Life Science
    • /
    • v.34 no.5
    • /
    • pp.356-364
    • /
    • 2024
  • Lymph nodes (LNs) are crucial sites where immune responses are initiated to combat invading pathogens in the body. LNs are organized into distinctive compartments by stromal cells. Stromal cell subsets constitute special niches supporting the trafficking, activation, differentiation, and crosstalk of immune cells in LNs. Fibroblastic reticular cells (FRC) are a type of stromal cell that form the three-dimensional structure networks of the T cell-rich zones in LNs, providing guidance paths for immigrating T lymphocytes. FRCs imprint immune responses by supporting LN architecture, recruiting immune cells, coordinating immune cell crosstalk, and presenting antigens. During inflammation, FRCs exert both spatial and molecular regulation on immune cells through their topological and secretory responses, thereby steering immune responses. Here, we propose a model in which FRCs regulate immune responses through a three-part scheme: setting up, supporting, or suppressing immune responses. FRCs engage in bidirectional interactions that enhance T cell biological efficiency. In addition, FRCs have profound effects on the innate immune response through phagocytosis. Thus, FRCs in LNs act as gatekeepers of immune responses. Overall, this study aims to highlight the emerging roles of FRCs in controlling both innate and adaptive immunity. This collaborative feedback loop mediated by FRCs may help maintain tissue function during inflammatory responses.

An Analysis of Students' Conceptions on Blood Circulation as Components: A Cross-sectional Study (혈액 순환 요소별 학생들의 개념 분석 : 횡단적 연구)

  • Kim, Mi-Young;Kim, Heui-Baik
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.6
    • /
    • pp.753-764
    • /
    • 2006
  • The concept of blood circulation is so complex, dynamic and abstract that students have difficulty in understanding it and students' preconceptions hardly change into scientific concepts even after the lessons. The purpose of this study is to examine middle school, high school, and undergraduate students' understanding of blood circulation and to find the reason why the lack of deep understanding is displayed in students' explanations for the blood circulation. The study consists of three parts. First, the test was designed to investigate students' ideas for blood circulation as components of the structure, the function, the behavior and the mechanism. Second, the test was applied to 7th, 10th and 13th graders to investigate the students' understanding of blood circulation and categorize the types of students' blood circulation model according to their academic level. Finally, the concepts the students had little understanding of were analyzed to decide which ontological category they fell into and further to inquire the characteristics of each concept. The results showed that many students comprehend the structure and the function of blood circulation components well, and there was no significant difference in students' understanding according to the academic level. In contrast, understanding the behavior and the mechanism of circulatory components has remarkably improved in high school students and undergraduates majoring in science and engineering. Also, students' blood circulation models were classified into seven different types. High school students and undergraduates majoring in science and engineering demonstrated a significantly higher percentage on the type of double-loop-branch compared to other academic levels. In addition, it was found that the lack of deep understanding was caused by students' misconceiving the 'equilibrium' category as 'event' category.

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) - (내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) -)

  • Ahn, Jin-Hwan;Ha, Chul-Won;Kim, Ho;Kim, Sung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 1999
  • Purpose : The importance of meniscal repair is well recognized. But transeciton of the posterior horn of the medial meniscus at the posterior tibial attachment is rarely documented and known irreparable. We experienced 9 cases of transection, and present clinical features and pull out suture technique. Methods and Materials : There were 9cases of transection of the posterior horn of medial meniscus from September 1998 to July 1999 in our hospital. Age was 59.3 years in average and ranged from 38 to 70years. Clinical features and MRI made diagnosis in all cases. We confirmed the diagnosis with arthroscopy and repaired the transection with pullout suture technique. Clinical features : Transection of the posterior horn of the medial meniscus at the posterior tibia attachment occurred frequently in middle aged people. They complained posterior knee pain, but they have no history of definitive trauma. Characteristically they had difficulty in full flexion of the knee and in having a squatting position. MRI is very important in diagnosis of transection, especially in coronal view, there is separation of the posterior horn of the meniscus from the posterior tibial attachment. Surgical technique : Pullout suture technique includes debridement of fibrous or scar tissue, exposure of the subchondral bone of the posterior tibial attachment site, suture the transected end of the meniscus with PDS suture, bone tunnel formation from the anteromedial aspect of the proximal tibia, insertion of wire loop through the tibia tunnel, pull the PDS suture through the tibia tunnel out of the joint and stabilize the PDS with post-tie technique to the proximal tibia. Conclusion : Transection of the posterior horn of the medial meniscus at the posterior tibial attachment is not common clinically and rarely documented. Clinical features and MRI are very important in diagnosis of this type tear. Arthroscopic pullout sutures is useful for treatment of this type tear of the meniscus.

  • PDF

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

Qualities and Anti-inflammatory Activity of Kyungokgos Sold in Local Markets (국내 시판 경옥고 제품의 품질 특성 및 항염증 활성)

  • Lee, Ka-Soon;Kim, Gwan-Hou;Kim, Hyun-Ho;Seong, Bong-Jae;Kim, Sun-Ick;Han, Seung-Ho;Kang, Eun Ju;Yoo, Yung Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.335-341
    • /
    • 2013
  • Kyungokgos purchased in local markets in Korea vary in their combination and mixing ratios during processing. This study was investigated qualities of Kyungokgos manufactured traditionally to evaluating its qualities. The general components of Kyungokgos were moisture (18.62~49.78%), ash (0.198~1.211%), protein (0.89~3.58%), lipid (0.16~1.14%) and carbohydrates (47.95~77.08%). The color values of L, a, and b were 26.49~73.87, 16.51~38.64, and 45.41~88.94, respectively. The viscosity was classified into three non-Newtonian type groups: high, medium, and non-dilatant, according to the increase of loop execution times. Three extracts (KOG-1, -7, and -8, in a 30-fold dilution) showed no cytotoxicity toward RAW 264.7 cells, while the extracts of KOG-2, -4, and -5 showed a low cytotoxic effect. KOG-1 and -2 extracts with low cytotoxicity markedly inhibited the production of the inflammatory mediators-nitric oxide (NO) and tumor necrosis factor-alpha (TNF-${\alpha}$) in LPS-stimulated RAW 264.7 cells. These results indicate that KOG-1 and -2 extracts have anti-inflammatory activity in LPS-stimulated RAW 264.7 macrophages.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.