• Title/Summary/Keyword: Longitudinal rib

Search Result 52, Processing Time 0.024 seconds

Local Behavior of Structural Details for Orthotropic Steel Deck Bridge with Longitudinal Rib of Open Section and Retrofitting Method of Fatigue Cracks (개단면리브를 갖는 강바닥판 교량의 국부거동 분석 및 피로균열 보강방안)

  • Lee, Sung Jin;Kyung, Kab Soo;Lee, Hee Hyun;Jeon, Jun Chang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.33-44
    • /
    • 2013
  • Although many studies have been performed for the structural details of orthotropic steel deck, most of them were focused on the trough rib of standard type, but not for orthotropic steel deck with longitudinal rib of open section used at beginning of the deck. In order to investigate the cause of fatigue crack for orthotropic steel deck bridge serviced 31 years with longitudinal rib of open section, in this study, the behavior characteristics of target structural details were analyzed based on measurement data under real traffic condition. Also the typical loading truck passing the target bridges was estimated with the structural analysis detailed, and the stresses and deformation patterns of target structural details were analyzed by performing the detailed structural analysis. Based upon the analysis, retrofitting methods of the fatigue crack were suggested and its validation was examined. From this study, it was clarified that fatigue crack of longitudinal rib with open section were affected with the stress increment by shear deformation in the rib and the occurrence of alternative stress due to moving vehicle. In addition, it was known that it is important to perform fatigue design reflected the local behavior of the structural details.

Stress Concentration of Longitudinal Rib to Deckplate Welded Joint in Orthotropic Steel Bridge Decks (강상판 종리브.바닥강판 응접연결부의 응력집중)

  • 장동일;최동호;최준혁;김도환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.343-350
    • /
    • 1999
  • Orthotropic steel bridge decks are potentially liable to cause fatigue cracks due to weld defects, residual stresses, and in-plane or out-of-plane stresses. In particular, the cracks propagated through deckplate in longitudinal rib to deckplate joints occur at weld toe and weld root due to stress concentrations. Numerical parametric studies are performed to show the Influence of the parameters on the stress concentration at the connection between the longitudinal rib and the deckplate. The parameters include root gap, toe angle $\theta$, toe radius $\rho$, and weld penetration. This study provides a fundamental point for the improvement of fatigue resistance and the estimation of the fatigue crack propagation in wekded joint details.

  • PDF

A Numerical Analysis on the Diaphragm and Cutout Structures for Improvement of Structure Performance in Orthotropic Steel Decks (강바닥판 구조성능 개선을 위한 보강재 설치에 관한 매개변수해석)

  • Shin, Jae-Choul;An, Ju-Og
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • Transverse rib web of orthotropic steel decks is highly susceptible to stress concentration due to out-of-plane and oil canning deformation caused by longitudinal rib distortion. In particular, stress concentrations are observed in the crossing point of longitudinal rib-transverse rib-deck plate, and cutout parts of transverse rib. The main objective of this study is to improve structure performance and to reduce the stress concentration of aforementioned susceptible parts. It is known that the installation of diaphragm alleviates stress concentrations between crossing point ant cutout. The influence of transverse rib placement and cutout width on stress concentrations was thoroughly investigated through numerical analyses. The numerical result showed that diaphragms produce the structural details for improved structure performance, when the transverse rib was placed in the same location with diaphragms. In any case, it is certain that the installation of diaphragms has more advantageous than the case without diaphragms in terms of structure performance of orthotropic steel decks. In this study, the distance ratio($y_i/y_{total}$) is defined as the ratio of the distance($y_{total}$) between the deck plate and longitudinal rib bottom to the distance($y_i$) between the deck plate and crossing point of longitudinal rib-transverse rib in cutout part. It has been found that the optimal distance ratio was 0.85 from the numerical simulation.

A study of Improvement of Stiffness for Plastic PET bottle with Different Geometries and Numbers of Rib (리브 형상 및 개수에 따른 사각플라스틱 페트병의 강성보강에 관한 연구)

  • Young-Hoon Lee;Bum-Jin Park;Eui-Chul Jung;Jung-Gil Oh;Seok-Guwan Hong
    • Design & Manufacturing
    • /
    • v.17 no.4
    • /
    • pp.33-41
    • /
    • 2023
  • Excessive use of plastic bottles contributes to a significant environmental issue due to the high volume of plastic waste generated. To address this, efforts are needed to reduce the weight of plastic bottles. However, indiscriminate weight reduction may compromise the essential rigidity required for plastic bottles. Extensive research on rib shape for pressure vessels are exists, but there is a few research of rib shapes to enhance the stiffness of plastic bottles. The following results were obtained from the analyses conducted in this study. 1) Among the rib cross-sections of square, trapezoid, and triangle, the buckling critical load of PET bottles with square-shaped ribs is improved by about 14% compared to the buckling critical load of PET bottles without ribs. 2) The buckling critical load is improved by about 18% when a square-shaped rib with an aspect ratio of 0.2 is applied, compared to the buckling critical load of the bottle without the rib. 3) When longitudinal and transverse square ribs were applied to the axial direction of the PET bottle, the buckling critical load was improved by about 32% and 58% compared to the buckling critical load of the PET bottle without ribs, respectively, indicating that applying longitudinal ribs is effective in reinforcing the stiffness of PET bottles. 4) When 14 transverse ribs were applied, the maximum improvement was about 48% compared to the buckling critical load of the plastic bottle without ribs. 5) When 3 longitudinal ribs were applied on each side, the maximum improvement was about 76% compared to the buckling critical load of the bottle without ribs. Therefore, it was concluded that for effective stiffness reinforcement of a 500ml square bottle with a thickness of 0.5mm, 3 square-shaped ribs with an aspect ratio of 0.2 should be applied in the longitudinal direction relative to the axial direction of the bottle.

Elastic Behavior Characteristics of GFRP Pipes Reinforced with Ribs (리브 보강 GFRP 관로의 탄성 좌굴거동 특성)

  • Seo Joo-Hyung;Han Taek-Hee;Yoon Ki-Yong;Kang Jin-Ook;Lee Myeoung-Sub;Kang Young-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.119-126
    • /
    • 2006
  • The elastic budding strength of a GFRP pipe reinforced with ribs was evaluated. The height and thickness of a rib and the spacing between two adjacent ribs were considered as factors affecting tlje budding strength of the pipe. And also, the ratio of the longitudinal stiffness and transverse stiffness was considered as the parameter affecting on the budding strength because GFRP is orthotropic material. Buckling strengths of various GFRP pipe models with different shapes and stiffness ratio were evaluated by FE analyses and a formula to estimate the elastic buckling strength of a rib-reinforced pipe made of orthotropic material was suggested from the regression with FE analysis results. Analysis results show that a rib-reinforced pipe has superior buckling strength to a general flat pipe and the suggested formula estimates accurate buckling strength of the rib-reinforced pipe.

  • PDF

A Numerical Analysis on the Diaphragm Structures for Improving Fatigue Performance in Orthotropic Steel Decks (강바닥판의 피로성능 향상을 위한 다이아프램 구조상세)

  • Shin, Jae Choul;An, Zu Og;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.559-573
    • /
    • 2007
  • Orthotropic steel decks are manufactured by welding thin plates therefore it is inevitable that there are abundant works of welding process. On connection of transverse rib web, crossing point of longitudinal rib, transverse rib and deck plate and cut-out parts of transverse rib are the significant position of stress concentration because of out of plane and oil-canning deformation caused by longitudinal rib distortion with shear force and distortion. At the current research, the crossing point where the orthotropic steel decks's effect of improving fatigue performance are high, not placing scallop and diaphragm which have same plane with transverse rib placed inside of longitudinal rib at the same time, the reduce effects of stress concentration at the cut-out section and the crossing are high. Especially the installation of the diaphragm causing great effects based on research results to stress concentration appearance reduce effects at the cut-out section, putting radius of curvature of the diaphragm's top and bottom as a target, as a result of carrying out the parametric analysis an optimal diaphragm form that has great effects in fatigue performance came to a conclusion. Also based on optimal diaphragm form, an advantage of the diaphragm optimal setting position for improvement of the fatigue performance came to a conclusion.

A Study on Structural Analysis of Reinforced Longitudinal Rib in Orthotropic Steel Deck Bridge (보강된 세로리브에 의한 강바닥판교의 응력변화 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.468-475
    • /
    • 2007
  • The Steel deck a structural analysis in head plate form change the objective bridge which it sells it accomplished a detailed structural analysis from the research which it sees and Bulk-head plate it accomplished. The length rib where the fatigue crack which is considerable generally occurs, width rib connection department and the length rib side, the width rib side it compares principal stress in the object and it does to sleep. It applied the grudge element model which it describes consequently after words and a load and a boundary condition and it executed it compared a static test and principal stress. It grasped the stress conduct of the The Steel deck petal which it follows in hand weaving rib affix location and the affix location to sleep in order to analyze a same location Bulk-head the head and comparison considered. From the detailed section which is reinforced with the stress investigation result hand weaving rib of the location which is weak in structural analysis result fatigue crack of form star reinforcement details basic form and Bulk-head the form which is reinforced with the head plate compared to principal stress investigation hour it is judged at the section which separates most.

  • PDF

Numerical Analysis Study for Optimal Design Method on Intersection between Longitudinal and Transversal Rib in Orthotropic Steel Deck Bridge (강바닥판교의 종리브-횡리브 교차연결 상세변화에 따른 최적설계방안의 수치해석 연구)

  • 배두병;공병승
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.3
    • /
    • pp.333-340
    • /
    • 2004
  • The use of the othotropic steel deck is steadily increased due to the advance of the technology in the steel bridges which recently have been longer. But the othotropic steel deck bridge is the structure that is very fragile to the fatigue, especially, the fatigue crack at the cross of the longitudinal rib and transversal rib is one of the biggest problems that othotropic steel deck bridges have. The causes of these fatigue cracks come from the secondary stress on out-plane behavior of transversal rib. In this study, we conducted the experiment to find the optimal details to improve fatigue strength on intersection between longitudinal rib and transversal rib in the othotropic steel deck bridge through numerical analysis using the experiment of the fatigue in the 3-dimensional real structure and program LUSAS. As a result of study, it is showed that the details of the korean standard section attached with a curved bulkhead plate is the most profitable. And, it is indicated that the stress which is generated when the reform improved section by parametic study can be reduced by about 50% at most or more. Along with the reduced stress and the longer interval between transversal ribs(G=400), the decreased steel amount by 4% and the shortened welding length by 34% make it possible to produce the othotropic steel deck bridge which is strong against fatigue.

Optimum Design of A-Pillar Trim for Occupant Protection (승원 안전을 고려한 승용차 A-Pillar Trim의 최적 설계)

  • 김형곤;강신일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2001
  • NHTSA has been conducting biomechanical studies to reduce inujuries sustained sustained during automotive collision. Furthermore, NHTSA added the regulation to the FMVSS 201, limiting the equivalent HIC(Head Injury Criterion) value under 1000. In the presont work, a methodology was developed for the optimum design of the A-pillar trim with rib-structures. The design variables for the rib-strucrures were the transverse spacing, the longitudinal spacing, and the thickness. The required sets of the design varibles were decided based on the design of experiments. The head impact simulations were carried out using the LS-DYNA3D, and the HIC(d) values were computed using the resulrs of the head impact simulation. The objective function was constructed using the response surface methed (RSM). When the obtained optimum values were not inside the region of interest, the design proceduers were repeated by changing the region of interest. Finally, an A-pillar trim with rib-structures, which resulred in HIC(d) value under 850 for 15 mph head-trim impact, was developed.

  • PDF

Plastic Reconstruction of Tuberculous Bronchostenosis with Rib Cartilage (결핵성 기관지협착 환자에 있어서 늑연골을 이용한 기관지성형술 치험 1례 보고-)

  • Kim, Ju-Hyeon;Lee, Yeong-Tak
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.782-786
    • /
    • 1988
  • We experienced plastic reconstruction of tuberculous bronchostenosis with patient`s rib cartilage. He suffered from coughing and sputum for 2months, and was treated for pulmonary tuberculosis 10 years ago. In preoperative bronchoscopy, left main bronchus was fibrotic obstructive and LUL bronchus was severely destructed. After thoracotomy, we harvested the rib cartilage at the 6th rib, and designed semicircular and tubular graft. And then onlayed the graft over the longitudinal bronchotomy site by simple interrupted sutures with 4-0 Vicryl Postoperative course was good, coughing and sputum disappeared. In postoperative bronchoscopy, the patch graft was good in that position, and the internal diameter was sufficient, but the granuloma was found in the stoma of LUL bronchus. He was discharged without any other event.

  • PDF