• 제목/요약/키워드: Longitudinal resistance

검색결과 235건 처리시간 0.023초

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Multi-potential capacity for reinforced concrete members under pure torsion

  • Ju, Hyunjin;Han, Sun-Jin;Kim, Kang Su;Strauss, Alfred;Wu, Wei
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.401-414
    • /
    • 2020
  • Unlike the existing truss models for shear and torsion analysis, in this study, the torsional capacities of reinforced concrete (RC) members were estimated by introducing multi-potential capacity criteria that considered the aggregate interlock, concrete crushing, and spalling of concrete cover. The smeared truss model based on the fixed-angle theory was utilized to obtain the torsional behavior of reinforced concrete member, and the multi-potential capacity criteria were then applied to draw the capacity of the member. In addition, to avoid any iterative calculation in the existing torsional behavior model, a simple strength model was suggested that considers key variables, such as the effective thickness of torsional member, principal stress angle, and strain effect that reduces the resistance of concrete due to large longitudinal tensile strain. The proposed multi-potential capacity concept and the simple strength model were verified by comparing with test results collected from the literature. The study found that the multi-potential capacity could estimate in a rational manner not only the torsional strength but also the failure mode of RC members subjected to torsional moment, by reflecting the reinforcing index in both transverse and longitudinal directions, as well as the sectional and material properties of RC members.

LONGITUDINAL WAVES, STORING AND AMPLIFYING CAPABILITY OF INFORMATION IN WATER MOLECULES AND QUANTUM RESONANCE SPECTROMETER

  • Oh, Hung-Kuk
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.18-28
    • /
    • 1996
  • The outer-most electrons of metal atoms and the remaining valence electrons of any molecular atoms make three-dimensional crystallizing $\pi$-bondings. The rotating electrons on the three-dimensional crystallizing $\pi$-bonding orbitals of atoms make $\pi$-far infrared rays. Longitudinal wave is a propagation of a bundle of $\pi$-far infrared rays, which are produced by a dynamic impact on a solid bar. The $\pi$-far infrared rays make three-dimensional crystallizing $\pi$-bondings in the material, which reproduce the same $\pi$-far infrared rays. If a current signal is input into water molecules under a given electric potential field with $\pi$-far infrared rays (input information), the signal can be amplified because the $\pi$-far infrared rays make the $\pi$-bondings, which reduce electric resistance. The three-dimensional crystallizing $\pi$-bondings can induce normal electrons to move from one orbital to next one with a aid of potential electric field. Quantum Resonance Spectrometer is composed of tesla coil absorbing $\pi$-far infrared rays, tesla coil emitting varying electromagnetic waves signal generator, signal storage, human body amplifier, signal analyzer and data indicator. The absorbing tesla coil making varying magnetic field and downward and upward electric field, which resonates the $\pi$-far infrared rays coming out from specimen and absorbs them. The modulated current signal from the input square signal can generate and emit varying electromagnetic waves from the tesla coil. The varying electro-magnetic waves make the three-dimensional crystallizing $\pi$-bondings and the $\pi$-far infrared rays in the water molecules.

  • PDF

철골 모멘트골조로 보강된 철근콘크리트 건물의 내진성능 평가 (Seismic Performance Evaluation of Non-Seismic Reinforced Concrete Buildings Strengthened by Perimeter Steel Moment Frame)

  • 김선웅
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.233-241
    • /
    • 2020
  • This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.

초등학교 학생의 수학불안 변화 분석: 종단연구 (Analysis of Changes in Mathematical Anxiety of Elementary School Students: A Longitudinal Study)

  • 김리나
    • 한국수학교육학회지시리즈E:수학교육논문집
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 2021
  • 수학불안은 수학에 대한 정서적·신체적 거부감을 통칭하는 용어이다. 학생들의 수학불안에 대해 이해하는 것은 수학학업 성취도 향상 뿐 아니라 미래 사회에 필요한 수학 인력 양성의 측면에서도 중요하다. 특히 수학불안은 대부분 초등학교시기에 발생할 가능성이 높으며, 후속 학습에 부정적인 영향을 미치기 때문에 초등학교에서 학생들의 수학불안 양상을 이해하는 것이 필요하다. 이에 본 연구는 시간의 경과에 따른 학생들의 수학불안 변화 패턴을 제시하고 이를 통계적으로 검증하였다. 249명의 초등학교 학생들의 수학불안을 4학년에서 6학년까지 3년 동안 추적 조사한 결과, 수학불안 양상의 다섯 가지 패턴을 확인하였다. 또한 본 연구에서는 수학불안 변화에 지속적인 영향을 미치는 것은 교사의 수학 수업에 대한 흥미도이며, 부모의 관심은 수학불안을 경감시키고, 사교육에 대한 부담감은 수학불안을 증가시킨다는 것을 확인하였다.

무도상 철도교 레일 장대화를 위한 궤도-교량 상호작용 해석 및 개량방안 분석 (Analysis of Track-Bridge Interaction and Retrofit Design for Installation of CWR on Non-ballasted Railway Bridge)

  • 윤재찬;이창진;장승엽;최상현;박성현;정혁상
    • 한국도시철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.383-392
    • /
    • 2018
  • 본 연구에서는 비교적 경간이 긴 트러스교를 포함한 무도상 교량을 대상으로 장대레일을 부설할 때 궤도-교량 상호작용으로 인한 레일 부가 축응력과 교량 지점 반력 등의 변화를 검토하여 레일 장대화를 위한 개량 방안을 분석하였다. 연구결과에 따르면 무도상 교량에서 장대레일을 부설할 경우 레일 부가 축응력과 지점 반력이 큰 폭으로 증가하는 것으로 나타났다. 레일 부가 축응력은 횡저항력을 충분히 확보할 경우 수용 가능하지만, 지점 반력이 증가하게 될 경우 받침이나 교각의 손상이 우려되고 대규모 보수 보강을 필요로 하므로 지점 반력을 완화시킬 수 있는 방안을 강구할 필요가 있다. 교량 가동단의 마찰저항을 고려하는 경우 레일 부가 축응력은 감소하지만 지점 반력에 미치는 영향은 매우 작은 것으로 나타났다. 반면 궤도 종저항력이 작아지면 레일 부가 축응력과 지점 반력이 모두 큰 폭으로 감소하는 것으로 나타났으며, 레일 부가 축응력이 큰 일부 구간에 ZLR 체결장치를 적용하는 경우 레일 부가 축응력 뿐 아니라 교량 지점 반력이 크게 감소하는 것으로 나타났다. 따라서 무도상 교량의 레일 장대화를 위하여 일부 ZLR 체결장치를 적용하고 궤도 종저항력을 줄이는 방안이 매우 효과적이라고 판단된다.

하중재하 패턴을 고려한 강바닥판의 정적거동 평가 (Evaluation of Static Behaviour of Orthotropic Steel Deck Considering the Loading Patterns)

  • 김석태;허영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.98-106
    • /
    • 2011
  • 강박스거더의 바닥틀은 바닥강판, 종방향 리브 및 횡방향 리브로 구성된다. 강바닥판 교량은 용접 접합부의 개소가 많고 중차량 접지하중과 반복응력의 증가에 의해 피로손상의 발생 가능성이 매우 높다. 일반적으로 강바닥판의 피로균열은 중차량 트럭하중의 반복적인 재하하중으로 인한 국부응력에 의하여 발생한다. 또한 중차량 통행량의 증가 및 통행차량의 대형화는 피로균열 발생 가능성을 촉진한다. 따라서 교량에 영향을 미치는 실제 통행 차량하중의 하중재하 패턴을 고려한 하중 접지면적에 따른 교량의 거동을 정확히 평가하는 것은 매우 중요하다. 본 연구는 강바닥판 교량에서 통행 차량의 접지면적과 하중재하 효과를 고려하여 설계하중에 의한 접지면적과 실제 통행 차량의 접지면적을 유한요소해석을 통하여 비교 평가하였다. 유한요소해석은 강바닥판 교량의 4가지 하중 재하패턴에 대하여 수행하였다, 또한 해석은 다이아프램의 설치 유무에 따른 통행트럭의 접지면적 영향을 비교 평가하였다. 유한요소해석 결과, 실제 싱글타이어의 하중재하면적이 설계하중의 접지면적보다 보다 큰 국부응력을 보였고, 바닥강판은 전륜하중인 싱글타이어 재하에 의해 가장 큰 영향을 받는 것으로 나타났다. 또한 다이아프램의 설치 유무는 탄성영역에서 다이아프램 설치가 강바닥판 가로리브와 세로리브 교차부의 피로저항에 대한 구조성능 개선에는 효과가 없는 것으로 나타났다.

구속효과를 고려한 토목섬유의 인발저항력 평가기법 (Assessment Method of Geosynthetic Pullout Resistance Considering Soil Confinement Effect)

  • 방윤경;이준대;전영근
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.135-148
    • /
    • 2001
  • 본 연구에서는, 인장력과 이에 수직방향으로 작용하는 압축음력을 동시에 고려한 직교이방성 합성부재의 인장력-변형률 관계식(Bhagwan, Agarwal & Brouoan, 1990)을 응용하여, 토목섬유인발저항력 및 인장력에 미치는 구속응력의 영향을 정량적으로 평가할 수 있는 기법을 제시하였다. 이를 위해서, 국내에서 판매되고 있는 부직포, 직포, 복합포 및 지오그리드 등의 토목섬유를 대상으로 구속신장시험(Confined Extension Test) 및 실내인발시험(Laboratory Pull-out Test)을 수행하였다. 시험결과를 토대로하여 구속응력이 토목섬유의 인장력-변형률 거동에 미치는 영향을 분석하였고, 구속응력에 의한 토목섬유 인장력 및 인발저항력의 변화를 정량적으로 평가하였다. 분석결과, 구속응력의 크기가 증가할수록 토목섬유의 할선계수가 뚜렷이 증가하였으며, 본 연구 제안방법에 의한 토목섬유-흙 사이의 마찰저항각 $\delta\; 및\; 보정계수\; a^2$값이 기존의 인발저항력 평가방법에 비하여 다소 큰 값을 나타내어, 인발저항력 산정시 토목섬유에 가해지는 구속음력의 크기를 고려하는 본 연구 제시방법의 경우에 보다 큰 인발저항력이 얻어짐을 알 수 있었다.

  • PDF

22.9[kV]이하 XLPE 전력케이블의 열 충격 시험 및 절연파괴 특성 (The Properties of Dielectric Breakdown and Thermal Stresses below 22.9[kV] Class XLPE Power Cable)

  • 김영석;송길목;김선구
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.54-60
    • /
    • 2008
  • 2002년부터 시행되어오고 있는 제조물 책임법에 의해 사고케이블의 원인분석과 사고패턴에 대한 데이터베이스화가 중요하다. 더욱이 가속열화상태에서 전력케이블 사고의 패턴 및 모의실험은 데이터베이스 시스템 구축에 필요하다. 본 논문에서는 열 열화 따른 22.9[kV]이하 케이블의 열 충격시험을 수행하였다. 이 시험은 IEC60811-3-1에 따른다. 시험결과로부터, 22.9[kV]급 A사 전력케이블은 표면이 변색되었고 길이방향으로 급격하게 감소되었다. 특히, A사 전력케이블의 열 중량 특성이 심하게 변함에 따라, 케이블 제조상의 문제일 것이라 추측된다. 만약 전력케이블의 제조상의 결함에 의한 것이라면, 피해자들은 PL환경 하에 손해배상을 받을 수 있을 것이다.

FE validation of the equivalent diameter calculation model for grouped headed studs

  • Spremic, Milan;Pavlovic, Marko;Markovic, Zlatko;Veljkovic, Milan;Budjevac, Dragan
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.375-386
    • /
    • 2018
  • Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, $d_G$. The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.