• Title/Summary/Keyword: Long-term Compressive Creep

Search Result 34, Processing Time 0.024 seconds

Evaluation of Long-Term Deformation Prediction Model on Frozen Sand Considering Fine Contents (세립분 함량을 고려한 동결 사질토의 장기변형 예측 모델 평가)

  • Hwang, Bumsik;Chae, Deokho;Cho, Wanjei
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.93-103
    • /
    • 2017
  • Many countries are interested in the development of the Antarctic area because of the abundant resources and living things of high research value. Korea completed the second Antarctic research station in 2014 and spurring the development of the Antarctic area by constructing runway for the airplanes and a third Antarctic research station. However, frozen soils, unlike typical soils, are sensitive to creep behavior due to the influence of ice and unfrozen water. The creep tests for evaluating creep behaviors on the frozen soils require expensive laboratory equipments and large amount of time. Thus, various empirical models had been developed to describe the unconfined compressive creep behavior of frozen soils. In this study, new analytical creep model on frozen sands was proposed by modifying Ting's Tertiary creep model with a new parameter considering fine contents. Thus, the unconfined compressive creep tests were conducted with the frozen specimens of dense Jumoonjin sand with fine contents of 0, 5, 10 and 15% under various loads at -$5^{\circ}C$, -$10^{\circ}C$ and -$15^{\circ}C$. Consequently, the modified Tertiary creep model with a new parameter for fine contents are not enough for the description of the acutal creep behavior of the frozen sand and new framework should be developed.

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

Development of Removable-Strand Compression Anchor (압축형 제거 앵커의 개발 및 성능 평가)

  • 김낙경;김성규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.339-346
    • /
    • 2001
  • For temporary excavation support in private land area, the strand of ground anchor should be removed In order to get permission to install anchors. The extractable or removable-strand compression anchor system was developed and evaluated by a series of pull-out load tests. Anchor pull-out tests were performed on seven instrumented full-scale low-pressure grouted anchors installed in weathered soil at the Geotechnical Experimentation Site at Sungkyunkwan University, Four anchors are the compression type anchors and three are the tension anchors. Performance test, creep test, and long term relaxation test were performed and presented. Load distributor was developed in order to distribute large compressive stresses in grout.

  • PDF

The Influence Factors on the Compensation of Column Shortening in Tall Buildings (초고층 건물의 Column Shortening보정에 미치는 영향요소)

  • Mun, Il-Won;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.208-215
    • /
    • 2018
  • The causes of column shrinkage and the codes that have been studied up to now are discussed. The documents mentioned in the code deal with the drying shrinkage, creep, compressive strength and elastic modulus of the specimen, and the elastic deformation calculated from the structural analysis. However, the deformation due to the temperature caused by the long term monitoring is less than that caused by the factors generated by the previous studies. In the previous studies, it was found that dehydration shrinkage, creep, and elastic deformation were not considered for temperature-induced deformation, while for the specimen experiments, the temperature-related items were replaced with the humidity-related terms The compensation value by the proposed equation showed error of 4.9 mm in the upper direction and 1.0mm in the lower direction when calculating column shortening, and it was found that its value by the proposed equation almost coincided with the measurement value in Site. Therefore, it is necessary to further study the temperature that can be omitted in calculating the existing column shortening, to consider the influence factors, and to supplement the criteria for the temperature measurement of the structure as well as the specimen tests.