• Title/Summary/Keyword: Long-segment

Search Result 302, Processing Time 0.026 seconds

Physical test study on double-row long-short composite anti-sliding piles

  • Shen, Yongjiang;Wu, Zhijun;Xiang, Zhengliang;Yang, Ming
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.621-640
    • /
    • 2017
  • The double-row long-short composite anti-sliding piles system is an effective way to control the landslides with high thrust. In this study, The double-row long-short composite anti-sliding piles with different load segment length (cantilever length) and different pile row spacing were studied by a series of physical tests, by which the influences of load segment length of rear-row piles as well as pile row spacing on the mechanical response of double-row long-short composite anti-sliding pile system were investigated. Based on the earth pressures in front of and behind the piles obtained during tests, then the maximum bending moments of the fore-row and the rear-row piles were calculated. By ensuring a equal maximum moments in the fore-row and the rear-row piles, the optimum lengths of the rear-row piles of double-row long-short composite system under different piles spacing were proposed. To investigate the validity of the reduced scale tests, the full-scale numerical models of the landside were finally conducted. By the comparisons between the numerical and the physical test results, it could be seen that the reduced scale tests conducted in this study are reliable. The results showed that the double-row long-short composite anti-sliding piles system is effective in the distribution of the landslide thrust to the rear-row and the fore-row piles.

Nucleotide Sequence Analysis of the RNA-dependent RNA Polymerase Gene of Infectious Pancreatic Necrosis Virus DRT Strain

  • Lee, Hyung-Hoan;Chung, Hye-Kyung;Lee, Seong-Hun
    • Journal of Microbiology and Biotechnology
    • /
    • v.4 no.4
    • /
    • pp.264-269
    • /
    • 1994
  • To determine the nucleotide sequence of the ds RNA segment B containing the RNA dependent RNA polymerase (RdRp) gene of the DRT strain of infectious pancreatic necrosis virus (lPNV), the cDNA of the ds RNA segment B of the DRT strain of IPNV was synthesized using the reverse transcriptase (RT)-polymerase chain reaction (PCR) and its cDNA nucleotide sequence was determined. The DRT segment B was 2, 783 bp long and contained only a single long open reading frame (ORF) of 2, 535 bp in length. This ORF nucleotides encoded the VPl protein, the putative RdRp of IPNV. The VPl protein comsisted of 845 amino acids. The molecular weight of the RdRp, as deduced from the nucleotide sequence, is 94, 426. The nucleotide sequence of the ORF of the DRT showed 89.7% homology to the Jasper strain, but 80.8% to the Sp strain. The amino acid sequence of the ORF of the DRT sho.wed 97.6% homology to the Jasper strain, but 88.7% to the Sp strain. The conserved GTP-binding motif was detected in VPl protein.

  • PDF

Analysis of Impact Response in a Poroelastic Spinal Motion Segment FE Model according to the Disc Degeneration (다공탄성체 척추운동분절 유한요소 모델에서 추간판의 변성이 충격 거동에 미치는 영향 해석)

  • 김영은;박덕용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.188-193
    • /
    • 2003
  • To predict changes in biomechanical parameters such as intradiscal pressure, and the shock absorbing mechanism in the spinal motion segment under different impact duration/loading rates, a three dimensional L3/L4 motion segment finite element model was modified to incorporate the poroelastic properties of the motion segment. The results were analyzed under variable impact duration for normal and degenerated discs. For short impact duration and a given maximum compressive force, relatively high cancellous pore pressure was generated as compared with a case of long impact duration, although the amount of impulse was increased. In contrast relatively constant pore pressure was generated in the nucleus. Disc degeneration increased pore pressure in the disc and decreased pore pressure in the cancellous core, which is more vulnerable to compressive fracture compared with intact case.

The Ultrastructure of Photoreceptor Cells in Frog Retina (개구리 망막에 있는 광수용세포의 미세구조)

  • Kim, Jin-Suk;Jeon, Jin-Seok
    • Applied Microscopy
    • /
    • v.25 no.4
    • /
    • pp.115-123
    • /
    • 1995
  • This study was carried out to observe the functional ultrastructures of photoreceptor cells in frog(Rana catesbeiana) retina using transmission electron microscope. The photoreceptor cells are divided into two types-rod and cone cells-consist of outer and inner segment. The long outer segment of rod cell contains dense stacks of membrane and formed vertical and horizontal folds. The outer segment of cone cell is small, and vertical and horizontal folds are not exist. The electron dense cytoplasm of rod cell contains compact mitochondria, Golgi complexes, and endoplasmic reticula. The inner segment of cone cell shows low electron density and contains a large lipid droplet in the upper part of inner segment. In addition, cone cell contains many mitochondria, Golgi complexes. rough endoplasmic reticula, ribosomes and numerous glycogen particles. It is believed that these ultrastructural characteristics are closely associated with photoreceptive function of photoreceptor cells in frog retina.

  • PDF

A technique for insertion of a long T-tube in tracheal stenosis (기관 협착에서 Long T-tube의 삽입 방법)

  • 백만종
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.664-666
    • /
    • 1993
  • A technique for insertion of a long silicone T-tube in patient with critical stenosis and high-risk resection and primary anastomosis of long segment of the distal trachea is presented. It was not easy to insert a long T-tube by existing methods because of flexibility of a T-tube and tightness of stenosis. So we used a silastic endotracheal tube and guiding wire as stylet of a T-tube. During insertion, ventilation was normally maintained through the lumen of endotracheal tube. This provided rapid relief from airway obstruction and asphyxation and is a easy, safe and effective method to restore patency of the major airways.

  • PDF

Long-term Follow-up Results of Short-segment Posterior Screw Fixation for Thoracolumbar Burst Fractures

  • Lee, Yoon-Soo;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.6
    • /
    • pp.416-421
    • /
    • 2005
  • Objective: Despite general agreement on the goals of surgical treatment in thoracolumbar burst fractures, considerable controversy exists regarding the choice of operative techniques. This study is to evaluate the efficacy of short-segment fixation for thoracolumbar burst fractures after long-term follow-up and to analyze the causes of treatment failures. Methods: 48 out of 60 patients who underwent short-segment fixation for thoracolumbar burst fractures between January 1999 and October 2002 were enrolled in this study. Their neurological status, radiological images, and hospital records were retrospectively reviewed. Simple radiographs were evaluated to calculate kyphotic angles and percentages of anterior body compression (%ABC). Results: The average kyphotic angles were $20.0^{\circ}$ preoperatively, $9.6^{\circ}$ postoperatively, and $13.1^{\circ}$ at the latest follow-up. The average %ABC were 47.3% preoperatively, 31.2% postoperatively, and 33.3% at the latest follow-up. The treatment failure, defined as correction loss by $10^{\circ}$ or more or implant failure, was detected in 6 patients (12.5%). 5 out of 6 patients had implant failures. 2 out of 5 patients were related with osteoporosis, and the other 2 were related with poor compliance of spinal bracing. 3 patients with poor initial postoperative alignment had implant failure. 4 patients with screws only on the adjacent vertebrae and not on the injured vertebra itself showed poor initial and overall correction. Conclusion: With proper patient selection, adequate intraoperative reduction with screw fixation involving the injured vertebra, and strict postoperative spinal bracing, the short-segment fixation is an efficient and safe method in the treatment of thoracolumbar burst fracture.

A STUDY ON THE EFFECT OF LSOLATED NERVE SEGMENT ON PERIPHERAL NERVE REGENERATION USING SILICONE TUBE (SILICONE TUBE에 삽입된 신경절편이 말초신경 결손부의 재생에 미치는 효과)

  • Hong, Chang-Soo;Park, No-Boo;Jang, Hyun-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.4
    • /
    • pp.317-330
    • /
    • 1995
  • The purpose of this study is to observe the stimulant effect of the isolated nerve segment on the peripheral nerve regeneration using silicone tube in rats. Sprague-Dawley female albino rats were used as experimental animals and nerve defects were made by resection of 14 mm-long segment of right sciatic nerves. In control group, the defects were bridged with the silicone tubes. In experimental group, the defects were bridged with the same manner and additionally, 2mm-long nerve segments were inserted at the center of the silicone tubes. 3 months later, the regenerated nerve tissue within the silicone tubes were examined by histologic study. Axonal diameters and numbers of axons were measured and all data were analyzed by using SAS package program. The results obtained were as follows : 1. The experimental group was increased than the control group in general diameters of the regenerated nerve fiber.(P<0.05) 2. The diameters of axons were increased in the experimental group compare to the control group.(P<0.05) 3. The numbers of axons were increased in the experimental group compare to the control group.(P<0.05)

  • PDF

First record of the family Cletopsyllidae (Copepoda: Harpacticoida) from Korean waters, with description of a new species

  • Song, Sung-Joon;Kim, Won;Hwang, Ui-Wook
    • Animal cells and systems
    • /
    • v.14 no.4
    • /
    • pp.351-360
    • /
    • 2010
  • A new species of the Cletopsyllidae belonging to the genus Isocletopsyllus Huys and Lee, 1999 is described from the materials collected from subtidal sandy bottoms at Jeju Island and Ulleung Island, Korea. So far, only two species of the genus Isocletopsyllus, viz. I. tertius (Por, 1964) from Israel and I. quartus (Soyer, 1966) from Banyuls-sur-Mer (France) are recorded, both from the Mediterranean Ocean. The new species can be clearly distinguished from its congeners by the combination of the following characters: (1) female antennule with a large process on the outer margin of first segment, (2) caudal rami with a bulbous proximal inner expansion, and shorter than those of other species (about four times long as wide in the new species), (3) second segment of P1 exopod with a short rod-like inner seta, (4) sexual dimorphism presented in the second endopodal segment of male P2, not in exopod of P4, and (6) female P5 with a very long exopod with very short second outer seta. A table comparing the modifications of swimming legs in the family Cletopsyllidae Huys and Lee, 1999 is presented. This is the first record of this family from Korea.

Short-segment Pedicle Instrumentation of Thoracolumbar Burst-compression Fractures; Short Term Follow-up Results

  • Shin, Tae-Sob;Kim, Hyun-Woo;Park, Keung-Suk;Kim, Jae-Myung;Jung, Chul-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2007
  • Objective : The current literature implies that the use of short-segment pedicle screw fixation for spinal fractures is dangerous and inappropriate because of its high failure rate, but favorable results have been reported. The purpose of this study is to report the short term results of thoracolumbar burst and compression fractures treated with short-segment pedicle instrumentation. Methods : A retrospective review of all surgically managed thoracolumbar fractures during six years were performed. The 19 surgically managed patients were instrumented by the short-segment technique. Patients' charts, operation notes, preoperative and postoperative radiographs (sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis, regional kyphosis), computed tomography scans, neurological findings (Frankel functional classification), and follow-up records up to 12-month follow-up were reviewed. Results : No patients showed an increase in neurological deficit. A statistically significant difference existed between the patients preoperative, postoperative and follow-up sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis and regional kyphosis. One screw pullout resulted in kyphotic angulation, one screw was misplaced and one patient suffered angulation of the proximal segment on follow-up, but these findings were not related to the radiographic findings. Significant bending of screws or hardware breakage were not encountered. Conclusion : Although long term follow-up evaluation needs to verified, the short term follow-up results suggest a favorable outcome for short-segment instrumentation. When applied to patients with isolated spinal fractures who were cooperative with 3-4 months of spinal bracing, short-segment pedicle screw fixation using the posterior approach seems to provide satisfactory result.