• Title/Summary/Keyword: Long-range Order Parameter

Search Result 17, Processing Time 0.022 seconds

Cation Ordering and Microwave Dielectric Properties of $Ba(Mg_{1/3}Nb_{2/3})O_3$Ceramics: I. Long-Range Order Parameter ($Ba(Mg_{1/3}Nb_{2/3})O_3$ 세라믹스의 양이온 규칙구조와 유전특성: I. 장거리 규칙도)

  • 김영웅;박재환;김윤호;박재관
    • Korean Journal of Crystallography
    • /
    • v.12 no.2
    • /
    • pp.76-80
    • /
    • 2001
  • We have studied the effect of sintering conditions on the long-range order parameter of the 1 : 2 cation ordering in Ba(Mg/sub 1/3/Nb/sub 2/3/)O₃microwave dielectrics prepared through a columbite precursor method. It is found that the order parameter depends strongly on the sintering conditions. As the heat-treatment time increases at 1350℃, the long-range order parameter decreases. When sintered at 1500℃ for 4 hours, BMN shows a high long-range order parameter of 0.94.

  • PDF

Dependency of Long-range Order Parameter on the Ordered Structure of $Pb(Mg_{1/3}Nb_{2/3})O_3$ Solid Solutions ($Pb(Mg_{1/3}Nb_{2/3})O_3$ 고용체의 규칙격자 구조에 있어서 장거리 규칙도의 의존성)

  • Park, Kyeong-Soon;Kim, Jwa-Yeon;Lee, Jae-Won;Kim, Kwang-Bae
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.415-424
    • /
    • 1998
  • The dependency of long-range order parameter on the ordered structure of $Pb(Mg_{1/3}Nb_{2/3})O_3$ solid solutions has been investigated by means of computer simulations of high-resolution lattice images. The computer image simulations were performed by the multislice method in a wide range of sample thicknesses, defocusing values, and long-range order parameters. It was found that the lattice images of the ordered structures were predominantly dependent on the long-range order parameter, The lattice images in a complete ordered structure showed a pseudo-hexagonal pattern. As the order parameter decreases, the simulated images changed slowly from a pseudo-hexagonal pattern to a rectangular pattern. The lattice images in a complete disordered structure showed a rectangular pattern. Also, the simulated images of the $Pb(Mg_xNb_{1-x})O_3$ with different Mg:Nb ratios obtained at a given long-range order parameter were basically the same patterns, irrespective of Mg and Nb compositions.

  • PDF

High-resolution Transmission Electron Microscopy of Ordered Structure for Lead Magnesium Niobate Solid Solutions ($Pb(Mg_{1/3}Nb_{2/3})O_3$ 고용체에서 고분해능 투과전자현미경을 이용한 구조 규칙화에 대한 연구)

  • Park, Kyeong-Soon
    • Applied Microscopy
    • /
    • v.27 no.1
    • /
    • pp.101-109
    • /
    • 1997
  • The nonstoichiometric ordering of Mg and Nb cations in undoped and La-doped lead magnesium niobate solid solutions has been investigated by means of high-resolution transmission electron microscopy and computer image simulation. High-resolution lattice images were obtained under various microscope imaging conditions and objective apertures. Computer image simulations were performed for a wide range of sample thickness, defocusing value, and long-range order parameter. The simulated images revealed that the lattice images of the ordered regions were predominantly dependent on the long-range order parameter. From the comparisons of the experimental and simulated images for the ordered regions, the long-range order parameter approximately ranged 0.2 to 0 7. It was also found that the ordered structure has a $(NH_4)_3-FeF_6$ structure, which consists of alternating Mg- and Nb-preferred sublattices along the (111) directions.

  • PDF

Study of Order-Disorder Phase Transition of $(Fe_{0.61}Ni_{0.39})_3V$V Alloy by Neutron Diffraction Method (중성자회절법을 이용한 $(Fe_{0.61}Ni_{0.39})_3V$ 합금의 규칙- 불규칙 상전이 연구)

  • 이정수;이창희
    • Korean Journal of Crystallography
    • /
    • v.13 no.1
    • /
    • pp.36-40
    • /
    • 2002
  • The order-disorder phase transition of (Fe/sub 0.61/Ni/sub 0.39/)₃V alloy that is annealed at various temperatures and time conditions was sty(lied with the examination of long-range order parameter(S) by using neutron diffraction method. As a result, the structure of the sample annealed at 680℃ for 94 h was not changed; that is, it existed iii perfect disordered state and showed face-centered cubic structure. Otherwise, samples which were annealed at temperature below 640℃ showed the value of long-range order parameter with 0 < S < 1 and phase transition into simple cubic structure partly. It was found that the annealed sample at 465℃ for 144 h is the most approximated to the thermal equilibrium state from the S-T/T/sub c/ related equation of Cowley.

Dielectric and Optical Study of Polymer Nematic Liquid Crystal Composite

  • Manohar, S.;Shukla, S.N.;Chandel, V.S.;Shukla, J.P.;Manohar, R.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.111-115
    • /
    • 2013
  • The dielectric anisotropy and dispersion of the real and imaginary part of the permittivity of commercially important nematic mixture E-24 and its polymer composite were investigated in the frequency range from 1 kHz to 10 MHz, and temperature range $14^{\circ}C$ to $55^{\circ}C$. The percentage optical transmittance and density have also been measured for both the systems. The results have been explained by assuming molecular rotation about the long molecular axis, under a hindering nematic potential. The dielectric anisotropy ${\Delta}{\varepsilon}$ is positive, and the mean dielectric permittivity falls with rising temperature. ${\Delta}{\varepsilon}$ is also used to determine the order parameter with varying temperature.

Structural and Magnetic Properties of Epitaxial FexCo100-x Alloys Grown on Cr Substrate

  • Hossain, M.B.;Kim, C.G.;Chun, B.S.;Kim, W.D.;Hwang, C.
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.1-4
    • /
    • 2014
  • We report the correlation between the magnetic properties and lattice parameter of $Fe_xCo_{100-x}$ alloys as a function of constituent concentration. The saturation magnetization increases with Fe content and has a maximum value at approximately x=70 at.%. However, collapse in relative saturation magnetization is observed at approximately 30 at.% to 70 at.% of Fe in $Fe_xCo_{100-x}$ alloys. The collapse is due to the formation of Co-Co and Fe-Fe antibonding states instead of Fe-Co bonds. The lattice parameter also shrinks at approximately 30 at.% to 70 at.% of Fe. This shrinkage is due to an increase in the number of nearest neighbor antisite atoms, which then leads to a decrease in the long range order parameter.

Stability analysis of porous multi-phase nanocrystalline nonlocal beams based on a general higher-order couple-stress beam model

  • Ebrahimi, Farzad;Barati, Mohammad Reza
    • Structural Engineering and Mechanics
    • /
    • v.65 no.4
    • /
    • pp.465-476
    • /
    • 2018
  • This article investigates buckling behavior of a multi-phase nanocrystalline nanobeam resting on Winkler-Pasternak foundation in the framework of nonlocal couple stress elasticity and a higher order refined beam model. In this model, the essential measures to describe the real material structure of nanocrystalline nanobeams and the size effects were incorporated. This non-classical nanobeam model contains couple stress effect to capture grains micro-rotations. Moreover, the nonlocal elasticity theory is employed to study the nonlocal and long-range interactions between the particles. The present model can degenerate into the classical model if the nonlocal parameter, and couple stress effects are omitted. Hamilton's principle is employed to derive the governing equations and the related boundary conditions which are solved applying an analytical approach. The buckling loads are compared with those of nonlocal couple stress-based beams. It is showed that buckling loads of a nanocrystalline nanobeam depend on the grain size, grain rotations, porosities, interface, elastic foundation, shear deformation, surface effect, nonlocality and boundary conditions.

Technique of Tension Length Calculation for 350km/h High Speed Catenary System (최고운행속도 350km/h급 전차선로 장력구간길이 계산 기법)

  • Chang, Sang-Hoon;Lee, Ki-Won;Kwon, Sam-Young;Park, Jae-Woong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.932-939
    • /
    • 2011
  • This paper deal with technique of tension length calculation for 350km/h high speed catenary system. Tension length affects in facility investment. Possibility of overlap increasing a tension length and the equipment investor decreases in order to decrease. Considers the parameter which specifies and the grudge which is possible long the fact that decides a tension length is the aim which is important plans overhead contact line. The element which decides a tension length with next following; (i) Operating range of tension device, (ii) Change of the horizontal tension which affects possibility of the effect which operates to the line and span, (iii) Tension of wire material the tensile force which is relation, (iv) Wire thermal expantion which relates with a standard temperature, (v) Curve radius, (vi) Wind velocity, (vii) Thermal range of overhead contact wire and mechanical design of tension mechanism etc.

  • PDF

Radiation-Laminar Free Convection in a Square Duct with Specular Reflection by Absorbing-Emitting Medium

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1346-1354
    • /
    • 2002
  • The purpose of this work is to study the effects of specularly reflecting wall under the combined radiative and laminar free convective heat transfer in an infinite square duct. An absorbing and emitting gray medium is enclosed by the opaque and diffusely emitting walls. The walls may reflect diffusely or specularly. Boussinesq approximation is used for the buoyancy term. The radiative heat transfer is evaluated using the direct discrete ordinates method. The parameters under considerations are Rayleigh number, conduction to radiation parameter, optical thickness, wall emissivity and reflection mode. The differences caused by the reflection mode on the stream line, and temperature distribution and wall heat fluxes are studied. Some differences are observed for the categories mentioned above if the order of the conduction to radiation parameter is less than order of 10$\^$-3/ fer the range of Rayleigh number studied. The differences at the side wall heat flux distributions are observed as long as the medium is optically thin. As the top wall emissivity decreases, the differences between these two modes are increased. As the optical thickness decreases at the fixed wall emissivity, the differences also increase. The difference of the streamlines or the temperature contours is not as distinct as the side wall heat flux distributions. The specular reflection may alter the fluid motion.

EEG Signal Characteristic Analysis for Monitoring of Anesthesia Depth Using Bicoherence Analysis Method (바이코히어런스 분석 기법을 이용한 마취 단계별 뇌파의 특성 분석)

  • Park Jun-Mo;Park Jong-Duk;Jeon Gye-Rok;Huh Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Although reachers have studied for a long time, they don't make criteria for anesthesia depth. anesthetists can't make a prediction about patient's reaction. Therefor, patients have potential risk such as poisonous side effect late-awake, early-awake and strain reaction. EEG are received from twenty-five patients who agreed to investigate themselves during operation with Enflurane-anesthesis in progress of anesthesia. EEG are divided pre-anesthesia, before incision of skin, operation 1, operation 2, awaking, post-anesthesia by anesthesia progress step. EEG is applied pre-processing, base line correct, linear detrend to get more reliable data. EEG data are handled by electronic processing and the EEG data are calculated by bicoherence. During pre-anesthesia and post anesthesia, appearance rate of bicoherence value is observed strong appearance rate in high frequency range($15\~30Hz$). During the anesthesia of patient, a strong appearance rate is revealed the low frequency area(0~10Hz). After bicoherence is calculated by percentage of a appearance rate, that is, Bicpara$\#$1, Bicpara$\#$2, Bicpara$\#$3 and Bicpara$\#$4 parameter are extracted. In result of bicoherence analysis, Bicpara$\#$2 and Bicpara#4 are considered that the best parameter showed progress of anesthesia effectively. And each separated bicoherence are calculated by average bicoherence's numerical value, divide by 2 area, appear by each BicHz$\#$1, BicHz$\#$2, and observed BicHz$\#$1/BicHz$\#$2's change. In result of bicoherence analysis, BicHz$\#$1, BicHz$\#$2 and BicHz$\#$1/BicHz$\#$2 are considered that the best parameter showed progress of anesthesia effectively. In conclusion, I confirmed the anesthesia progress phase, concluded to usefulness of parameter on bispectrum and bicoherence analysis and evaluated the depth of anesthesia. In the future, it is going to use for doctor's diagnosis and apply to protect an medical accident owing to anesthesia.