• Title/Summary/Keyword: Long pulse

Search Result 444, Processing Time 0.026 seconds

Strain Analysis of Longitudinal Reinforcing Steels of RC Bridge Piers Under Shaking Test (진동대 실험에 의한 RC교각의 주철근 변형률 분석)

  • Hong, Hyun-Ki;Yang, Dong-Wook;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.93-96
    • /
    • 2008
  • The near fault ground motion(NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Turkey Izmit (1999), Japan Kobe(1995), Northridge(1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the far fault ground motion(FFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on RC bridge piers without lap-spliced longitudinal reinforcing steels. The seismic performance of two RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, Two of four identical RC bridge piers were tested under a quasi-static load, and the others were under a pseudo-dynamic load. The respectively two RC bridge pier is comparatively subjected to Pseudo-dynamic loadings and Quasi-Static loadings. This paper indicated that more gives bigger ultimate strain of longitudinal steels to be fractured at bigger PGA motion.

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Adsorption of residual gases on carbon nanotubes and their field emission properties

  • Lee, Han-Sung;Jang, Eun-Soo;Goak, Jeung-Choon;Kim, Jin-Hee;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.51-51
    • /
    • 2008
  • Carbon nanotubes (CNTs) have long been reported as an ideal material due to their excellent electrical conductivity and chemical and mechanical stability as well as their high aspect ratios for field emission devices. CNT emitters made by screen printing the organic binder-based CNT paste may act as a source to release gases inside a vacuum panel. These residual gases may cause a catastrophic damage by electrical arcing or ion bombardment to the vacuum microelectronic devices and may change their physical or electrical properties by adsorbing on the CNT emitter surface. In this study, we analyzed the composition of residual gases inside the vacuum-sealed panel by residual gas analyzer (RGA), investigating the effects of individual gases of different kinds at several pressures on the field emission characteristics of CNT emitters. The residual gases included $H_2$, CO, $CO_2$, $N_2$, $CH_4$, $H_2O$, $C_2H_6$, and Ar. Effect of residual gases on the field emission was studied by observing the variation of the pulse voltages with the duty ratio of3.3% to keep the constant emission current of $28{\mu}A$. Each gas species was introduced to a vacuum chamber up to three different pressures ($5\times10^{-7}$, $5\times10^{-6}$, and $5\times10^{-5}$ torr) each for 1 h while electron emission was continued. The three different pressure regions were separated by keeping a high vacuum of $\sim10^{-8}$ torr for a 1 h. The emission was terminated 6 h after the third gas exposure was completed. Field emission characteristics under residual gases will be discussed in terms of their adsorption and desorption on the surface of CNTs and the resultant change of work function.

  • PDF

Effects of disturbance timing on community recovery in an intertidal habitat of a Korean rocky shore

  • Kim, Hyun Hee;Ko, Young Wook;Yang, Kwon Mo;Sung, Gunhee;Kim, Jeong Ha
    • ALGAE
    • /
    • v.32 no.4
    • /
    • pp.325-336
    • /
    • 2017
  • Intertidal community recovery and resilience were investigated with quantitative and qualitative perspectives as a function of disturbance timing. The study was conducted in a lower intertidal rock bed of the southern coast of South Korea. Six replicates of artificial disturbance of a $50cm{\times}50cm$ area were made by clearing all visible organisms on the rocky substrate in four seasons. Each of the seasonally cleared plots was monitored until the percent cover data reached the control plot level. There was a significant difference among disturbance timing during the recovery process in terms of speed and community components. After disturbances occurred, Ulva pertusa selectively preoccupied empty spaces quickly (in 2-4 months) and strongly (50-90%) in all plots except for the summer plots where non-Ulva species dominated throughout the recovery period. U. pertusa acted as a very important biological variable that determined the quantitative and qualitative recovery capability of a community. The qualitative recovery of communities was rapid in summer plots where U. pertusa did not recruit and the community recovery rate was the lowest in winter plots where U. pertusa was highly recruited with a long duration of distribution. In this study, U. pertusa was a pioneer species while being a dominant species and acted as a clearly negative element in the process of qualitative recovery after disturbance. However, the negative effect of U. pertusa did not occur in summer plots, indicating that disturbance timing should be considered as a parameter in understanding intertidal community resilience in temperate regions with four distinct seasons.

The Variation of Tagging Contrast-to-Noise Ratio (CNR) of SPAMM Image by Modulation of Tagline Spacing

  • Kang, Won-Suk;Park, Byoung-Wook;Choe, Kyu-Ok;Lee, Sang-Ho;Soonil Hong;Haijo Jung;Kim, Hee-Joung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.360-362
    • /
    • 2002
  • Myocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. Tagging contrast of such a tagging images can affect to the accuracy of the estimation of tag intersection in order to analyze the myocardial motion. Tagging contrast can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) experimentally. One healthy volunteer was undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner (Gyroscan Intera, Philips Medical System, Netherland). Horizontally modulated stripe patterns were imposed with a range from 3.6mm to 9.6mm of tagline spacing. Images of the left ventricle (LV) wall were acquired at the mid-ventricle level during cardiac cycle with FEEPI (TR/TE/FA=5.8/2.2/10). Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of short tagline spacing than in case of long tagline spacing. In the same heart phase, CNR was increased corresponding with tag line spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing.

  • PDF

Effect of fiber type and content on properties of high-strength fiber reinforced self-consolidating concrete

  • Tuan, Bui Le Anh;Tesfamariam, Mewael Gebregirogis;Hwang, Chao-Lung;Chen, Chun-Tsun;Chen, Yuan-Yuan;Lin, Kae-Long
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.299-313
    • /
    • 2014
  • Effects of polypropylene (PP) fibers, steel fibers (SF) and hybrid on the properties of highstrength fiber reinforced self-consolidating concrete (HSFR-SCC) under different volume contents are investigated in this study. Comprehensive laboratory tests were conducted in order to evaluate both fresh and hardened properties of HSFR-SCC. Test results indicated that the fiber types and fiber contents greatly influenced concrete workability but it is possible to achieve self consolidating properties while adding the fiber types in concrete mixtures. Compressive strength, dynamic modulus of elasticity, and rigidity of concrete were affected by the addition as well as volume fraction of PP fibers. However, the properties of concrete were improved by the incorporation of SF. Splitting tensile and flexural strengths of concrete became increasingly less influenced by the inclusion of PP fibers and increasingly more influenced by the addition of SF. Besides, the inclusion of PP fibers resulted in the better efficiency in the improvement of toughness than SF. Furthermore, the inclusion of fibers did not have significant effect on the durability of the concrete. Results of electrical resistivity, chloride ion penetration and ultrasonic pulse velocity tests confirmed that HSFR-SCC had enough endurance against deterioration, lower chloride ion penetrability and minimum reinforcement corrosion rate.

Fast Precessional Motion of Co/Pd Multilayer Systems Induced by Heat Treatment

  • Sohn, Jeong-Woo;Lee, Kyeong-Dong;Song, Hyon-Seok;Kim, Seon-Ock;Kim, Ji-Wan;Jeong, Jae-Woo;Shin, Sung-Chul
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2010.06a
    • /
    • pp.94-94
    • /
    • 2010
  • Co/Pd multilayer systems have been investigated with much attention for a long time due to the high and easily controllable perpendicular magnetic anisotropy. Two [Pd(1)/Co(0.4 nm)]5 multilayer systems - one is as-deposit, and the other is annealed at $350^{\circ}C$ - are studied with an all-optical approach. A two-color optical pump probe setup using 30 fs laser pulse at 82 MHz repetition rate is used to measure the time-resolved magneto-optical Kerr signal. It turns out the heat treatment enhances the perpendicular magnetic anisotropy, and leads to faster magnetization precession. The frequency reaches 30 GHz in the annealed sample, which is a factor of 2 larger compared to the as-deposit film.

  • PDF

Microvascular Anastomosis of Hepatic Artery in Children Undergoing Liver Transplantation (소아 간이식에서 간동맥의 미세혈관 문합술)

  • Jin, Ung Sik;Chang, Hak;Minn, Kyung Won;Yi, Nam Joon;Suh, Kyung Suk
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.454-457
    • /
    • 2006
  • Purpose: The anastomosis of hepatic artery to recipient vessel has a major role in a liver transplantation, so its occlusion is the most important cause of failure of liver transplantations. We made the study to reveal the peculiarities in pediatric liver transplantations compared with adult cases. Methods: From January 1999 to September 2005, we performed 99 cases of pediatric liver transplantation. The mean age at operation was 4.17 years of age. The hepatic vein and portal vein are anastomosed by the general surgeons and then the hepatic artery is anastomosed by the plastic surgeons. The Doppler ultrasonography and computed tomography were used for postoperative checkup for hepatic artery patency. Results: There were no immediate complications, but hepatic arterial occlusion was developed in 3 cases (2.8%). In pediatric patients, the anastomosis of hepatic artery is more difficult than adults because of the rapid respiratory and pulse rate, the small vascular diameter, and the large gap of diameter difference between the recipient and the donor vessels. Conclusion: We could confirm that pediatric liver transplantations are relatively safe but long learning curve was needed.

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

The Power of Simultaneous Multi-frequency Observations for mm-VLBI: Beyond Frequency Phase Transfer

  • Zhao, Guang-Yao;Algaba, Juan Carlos;Lee, Sang Sung;Jung, Taehyun;Dodson, Richard;Rioja, Maria;Byun, Do-Young;Hodgson, Jeffrey;Kang, Sincheol;Kim, Dae-Won;Kim, Jae-Young;Kim, Jeong-Sook;Kim, Soon-Wook;Kino, Motoki;Miyazaki, Atsushi;Park, Jong-Ho;Trippe, Sascha;Wajima, Kiyoaki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.46.2-46.2
    • /
    • 2017
  • Atmospheric propagation effects at millimeter wavelengths can significantly alter the phases of radio signals and reduce the coherence time, putting tight constraints on high frequency Very Long Baseline Interferometry (VLBI) observations. In previous works it has been shown that non-dispersive (e.g. tropospheric) effects can be calibrated with the frequency phase transfer (FPT) technique. The coherence time can thus be significantly extended. Ionospheric effects, which can still be significant, remain however uncalibrated after FPT, as well as the instrumental effects. In this work, we implement a further phase transfer between two FPT residuals (i.e. so-called FPT2) to calibrate the ionospheric effects based on their frequency dependence. We show that after FPT2, the coherence time at 3 mm can be further extended beyond 8 hours, and the residual phase errors can be sufficiently canceled by applying the calibration of another source, which can have a large angular separation from the target (> $20{\circ}$). Calibrations for all-sky distributed sources with a few calibrators are also possible after FPT2. One of the strengths and uniqueness of this calibration strategy is the suitability for high frequency all-sky survey observations including very weak sources. We discuss the introduction of a pulse calibration system in the future to calibrate the remaining instrumental effects and allowing the possibility of imaging the source structure at high frequencies with FPT2, where all phases are fully calibrated without involving any sources other than the target itself.

  • PDF