• 제목/요약/키워드: Long cable

Search Result 499, Processing Time 0.033 seconds

A Study on Tension for Cables of a Cable-stayed Bridge Damper is Attached (댐퍼가 부착된 사장교의 케이블 장력에 관한연구)

  • Park, Yeon Soo;Choi, Sun Min;Yang, Won Yeol;Hong, Hye Jin;Kim, Woon Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 2008
  • Recently, many ocean bridges that connect land to island or island to island have been constructed along with the improvement of the nation's economy. Long-span bridges can be categorized as suspension bridge, cable-stayed bridge, arch bridge and truss bridge. In this study, correction with respect to construction error can be presented on site through the monitoring of the cable tension change of real structure for four major construction stages so that construction accuracy, including the management of profiles, can be improved. A vibration method, the so-called indirect method that uses the cable's natural frequency changes from the acceleration sensor installed on the cable, is applied in measuring cable tension. In this study, the estimation formula for the effective length of cable with damper is presented by comparing and analyzing between actual measurement and analysis result for the change of the cable's effective length. By the way, it is known that the reliability of estimating cable tension by applying the former method that uses the net distance from damper to anchorage is low. Therefore, for future reference of the maintenance stage, the presented formula for estimating the effective length of cable can be used as a reference for the rational decision-making, such as the re-tensioning and replacement of cable.

A Study on the Bending and Torsional Behaviors of Cable-Stayed Bridges under a Concentrated Moving Load (집중 이동하중을 받는 사장교의 휨 및 비틈 거동에 관한 연구)

  • Chang, Sung Pil;Yhim, Sung Soon;Chu, Seok Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.3
    • /
    • pp.1-12
    • /
    • 1989
  • The nonlinearity of a cable-stayed bridge results from the large displacement of main girder due to a long span, the catenary action of cables and the flexural stiffness reduced by large axial forces. The dynamic behaviour of a cable-stayed bridge plays an important role in determining its safety. Especially, when the eccentrically moving load is applied to a cable-stayed bridge, the torsional vibration and vertical vibration are coupled and moreover the variation of cable tensions shows important dynamic characteristics. This dissertation presents a theoretical study and a finite element procedure for analysis of a cable-stayed bridge under a eccentrically moving load. Attention is focused on the dynamic behaviours such as dynamic increments of cable tensions and nodal displacements, with the variety of velocities and eccentricities of moving load. It is found that a moving load with eccentricity can have significant effects upon the responses; the torsion of bridge deck and the increments of cable tensions, according to the present results in this study.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Investigation on wind stability of three-tower cable-stayed-suspension hybrid bridges under skew wind

  • Xin-Jun Zhang;Li Bowen;Nan Zhou
    • Wind and Structures
    • /
    • v.38 no.6
    • /
    • pp.427-443
    • /
    • 2024
  • By using a computational program of three-dimensional aerostatic and aerodynamic stability analysis of long-span bridges under skew wind, the dynamic characteristics and structural stability(including the aerostatic and aerodynamic stability) of a three-tower cable-stayed-suspension hybrid bridge with main span of 1 400 meters are investigated numerically under skew wind, and the skew wind and aerostatic effects on the aerostatic and aerodynamic stability of three-tower cable-stayedsuspension hybrid bridge are ascertained. The results show that the three-tower cable-stayed-suspension hybrid bridge is a longspan structure with greater flexibility, and it is more susceptible to the wind action. The aerostatic instability of three-tower cable-stayed-suspension hybrid bridges is characterized by the coupling of vertical bending and torsion of the girder, and the skew wind does not affect the aerostatic instability mode. The skew wind has positive or negative effects on the aerostatic stability of the bridge, the influence is between -5.38% and 4.64%, and in most cases, it reduces the aerostatic stability of the bridge. With the increase of wind yaw angle, the critical wind speed of aerostatic instability does not vary as the cosine rule as proposed by the skew wind decomposition method, the skew wind decomposition method may overestimate the aerostatic stability, and the maximum overestimation is 16.7%. The flutter critical wind speed fluctuates with the increase of wind yaw angle, and it may reach to the minimum value under the skew wind. The skew wind has limited effect on the aerodynamic stability of three-tower cable-stayed-suspension hybrid bridge, however the aerostatic effect significantly reduces the aerodynamic stability of the bridge under skew wind, the reduction is between 3.66% and 21.86%, with an overall average drop of 11.59%. The combined effect of skew and static winds further reduces the critical flutter wind speed, the decrease is between 7.91% and 19.37%, with an overall average decrease of 11.85%. Therefore, the effects of skew and static winds must be comprehensively considered in the aerostatic and aerodynamic stability analysis of three-tower cable-stayed-suspension hybrid bridges.

Behavior of FRP-Concrete Composite Deck for a Cable Supported Bridge (사장교용 FRP-콘크리트 합성 바닥판의 거동 특성)

  • Cho, Keun-Hee;Park, Sung-Yong;Kim, Sung-Tae;Cho, Jeong-Rae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.51-52
    • /
    • 2009
  • A new-type FRP-concrete composite deck is developed and experimentally verified, which is economically applicable to a bridge with a long span exhibiting high cost effectiveness according to reducing self-weight such as cable supported bridge.

  • PDF

Beffeting Analysis of Long Span Cable-stayed Bridge using PCCAP (PCCAP을 이용한 장대 사장교의 버페팅 해석)

  • 유원진;이석용;남효승;이완수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.202-208
    • /
    • 2003
  • In this study, a time domain analysis is presented for investigation on the buffeting response of cable-stayed bridge during both erection and completion stages. The main span length and width of deck are 520 m and 15.1m, each. Since the ratio of span over width is 34.44, aerodynamic stability of the bridge during erection is expected to dominate the safety of the bridge in construction stage. Several conclusions regarding different construction stages and temporary wind cables are obtained.

  • PDF

Long term monitoring of a cable stayed bridge using DuraMote

  • Torbol, Marco;Kim, Sehwan;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.453-476
    • /
    • 2013
  • DuraMote is a remote sensing system developed for the "NIST TIP project: next generation SCADA for prevention and mitigation of water system infrastructure disaster". It is designed for supervisory control and data acquisition (SCADA) of ruptures in water pipes. Micro-electro mechanical (MEMS) accelerometers, which record the vibration of the pipe wall, are used detect the ruptures. However, the performance of Duramote cannot be verified directly on a water distribution system because it lacks an acceptable recordable level of ambient vibration. Instead, a long-span cable-stayed bridge is an ideal test-bed to validate the accuracy, the reliability, and the robustness of DuraMote because the bridge has an acceptable level of ambient vibration. The acceleration data recorded on the bridge were used to identify the modal properties of the structure and to verify the performance of DuraMote. During the test period, the bridge was subjected to heavy rain, wind, and a typhoon but the system demonstrates its robustness and durability.

Construction Stage Analysis of Extradosed PSC Box Bridges (Extradosed PSC Box 교의 시공단계해석)

  • 윤군진;이완수;이종신;김성찬
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.347-354
    • /
    • 2001
  • Extradosed PSC Box bridges, newly emerging type of structures in construction market, have a characteristic in that external tendons are used for strengthening PSC Box girder like stay cables in cable stayed bridges. In this study, a series of constructions stage analysis procedure, including initial shape analysis, backward analysis and forward analysis, have been performed in order to investigate long-term behavior of extradosed PSC box bridges, using PCCAP-a computer program for time-dependent stage analysis of PSC cable stayed bridges. CEB-FIP 1978 model was used for the consideration of time-dependent effect of concrete material. Showing the validity of the analysis results with RM SPACE FRAME, it has been confirmd that time-dependent effects become less consequential as the stiffness of girder becomes larger.

  • PDF

Failure Analysis of LV URD Cable based on FMEA (FMEA에 근거한 LV URD 케이블의 고장분석)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok;Kim, Sun-Gu;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.90-98
    • /
    • 2007
  • The objective of this investigation was to reveal the cause of the faulted cable(LV URD(low voltage underground) cable). For the analysis, various types or equipments such as external pattern, thermal pattern, surface structure, thermal analysis, and property distribution were deployed. The international standards and the specification provided by the manufacturer of faulted cable were examined whether it fit the standards. The summary is as follows. (1) Discovered as a factor lowering insulation performance of the faulted cable: minimum thickness of the insulation layer specified by IEC 60502-1 and IEC 60811-1-1 was not fit. (2) Infrared absorption peaks measured by FT-IR spectrometer revealed that the measurements made for the same material did not conform and it is an important basis for proving heterogeneous composition of the insulation material. (3) It was found that PVC bedding was thermally fragile and therefore long term exposure at the site could cause similar fault pattern.