• 제목/요약/키워드: Long bone fractures

검색결과 95건 처리시간 0.022초

전복막출혈이 동반된 골반골절 (Pelvic Bone Fracture with Preperitoneal Hemorrhage)

  • 김중석;설영훈;고승제;예진봉;박상순;구관우;김영철
    • Journal of Trauma and Injury
    • /
    • 제28권4호
    • /
    • pp.272-275
    • /
    • 2015
  • Pelvic bone fracture with unstable vital signs is a life-threatening condition demanding proper diagnosis and immediate treatment. Unlike long bones, the pelvic bone is a three dimensional structure with complex holes and grooves for vessels and nerves. Because of this complexity, a pelvic bone fracture can lead to complicated and serious bleeding. We report a case of a fifty-year-old male suffering from a pelvic bone fracture due to a fall. An imaging study showed fractures of both the superior and the inferior ramus of the pubic bone, with contrast extravasation underneath them, resulting in a large preperitoneal hematoma. He was sent for angiography, which revealed a hemorrhage from a branch of the left obturator artery. Embolization was done with a glue and lipiodol mixture. The patient recovered without complication, and was discharged at four weeks after admission.

  • PDF

Reconstruction of a Severe Open Tibiofibular Fracture using an Ipsilateral Vascularized Fractured Fibula with a Thoracodorsal Artery Perforator Free Flap

  • Lan Sook Chang;Dae Kwan Kim;Ji Ah Park;Kyu Tae Hwang;Youn Hwan Kim
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.523-528
    • /
    • 2023
  • The Gustilo IIIB tibiofibular fractures often result in long bone loss and extensive soft tissue defects. Reconstruction of these complex wounds is very challenging, especially when it includes long bone grafts, because the donor site is limited. We describe our experience using a set of chimeric ipsilateral vascularized fibula grafts with a thoracodorsal artery perforator free flap to reconstruct the traumatic tibia defects. A 66-year-old male suffered a severe comminuted tibia fracture and segmented fibula fracture with large soft tissue defects as a result of a traffic accident. He also had an open calcaneal fracture with soft tissue defects on the ipsilateral side. All the main vessels of the lower extremity were intact, and the cortical bone defect of the tibia was almost as large as the fractured fibula segment. We used an ipsilateral vascularized fibula graft to reconstruct the tibia and a thoracodorsal artery perforator flap to resurface the soft tissue, using the distal ends of peroneal vessels as named into sequential chimeric flaps. After 3 weeks, the calcaneal defect was reconstructed with second thoracodorsal artery perforator free flap. Reconstruction was successful and allowed rapid rehabilitation because of reduced donor site morbidity.

신속 조형 모델을 이용한 안와바닥 골절 정복술 (Effective Reconstruction of Extensive Orbital Floor Fractures Using Rapid Prototyping Model)

  • 김혜영;오득영;이우성;문석호;서제원;이중호;이종원;안상태
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.633-638
    • /
    • 2010
  • Purpose: Orbital bone is one of the most complex bones in the human body. When the patient has a fracture of the orbital bone, it is difficult for the surgeon to restore the fractured orbital bone to normal anatomic curvature because the orbital bone has complex curvature. We developed a rapid prototyping model based on a mirror image of the patient's 3D-CT (3 dimensional computed tomography) for accurate reduction of the fractured orbital wall. Methods: A total of 7 cases of large orbital wall fracture recieved absorbable plate prefabrication using rapid prototyping model during surgery and had the manufactured plate inserted in the fracture site. Results: There was no significant postoperative complication. One patient had persistent diplopia, but it was resolved completely after 5 weeks. Enophthalmos was improved in all patients. Conclusion: With long term follow-up, this new method of orbital wall reduction proved to be accurate, efficient and cost-effective, and we recommend this method for difficult large orbital wall fracture operations.

Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

  • Lee, Yewon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.679-685
    • /
    • 2014
  • Background Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures. Methods Between March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws. Results Contour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed. Conclusions The subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

Fat Embolism Syndrome - Three Case Reports and Review of the Literature

  • Grigorakos, Leonidas;Nikolopoulos, Ioannis;Stratouli, Stamatina;Alexopoulou, Anastasia;Nikolaidis, Eleftherios;Fotiou, Eleftherios;Lazarescu, Daria;Alamanos, Ioannis
    • Journal of Trauma and Injury
    • /
    • 제30권3호
    • /
    • pp.107-111
    • /
    • 2017
  • The fat embolism syndrome (FES) represents a condition, usually with traumatic etiology, which may pose challenges to diagnosis while its treatment usually requires supportive measures in the intensive care units (ICUs). The clinical criteria, including respiratory and cerebral dysfunction and a petechial rash, along with imaging studies help in diagnosis. Here we present three case reports of young male who developed FES and were admitted to our ICUs after long bones fractures emerging after vehicle crashes and we briefly review FES literature. All patients' treatment was directed towards: 1) the restoration of circulating volume with fresh blood and/or plasma; 2) the correction of acidosis; and 3) immobilization of the affected part. All patients recovered and were released to the orthopedic wards. The incidence of cases of patients with FES admitted in our ICUs records a significant decrease. This may be explained in terms effective infrastructure reforms in Greece which brought about significant improvement in early prevention and management.

Delayed Diagnosis of a Tibial Stress Fracture Associated with Glucocorticoid and Methotrexate Therapy in a Patient with Rheumatoid Arthritis: A Case Report

  • Shin, Hye Jeong;Lim, Yi Gun;Lee, Gi Hyang;Lee, Hyun Seok;Song, Beom Yong;Choi, Yoo Min
    • Journal of Acupuncture Research
    • /
    • 제39권1호
    • /
    • pp.64-69
    • /
    • 2022
  • The risk of stress fractures is associated with rheumatoid arthritis (RA), which can aggravate bone loss. We report the case of a patient who was on long-term medication for RA presenting with lower extremity pain on the left and swelling without trauma. Magnetic resonance imaging and plain radiographs at the previous hospital showed no signs of fracture, but radiographs performed later, revealed a stress fracture of the left distal tibia. The stress fracture may have occurred due to multiple reasons such as long-term use of methotrexate and glucocorticoids, active RA, postmenopausal state, and immobility. Suspicion of a stress fracture should not be ruled out especially in RA patients with persistent pain, even if the radiographical findings are normal. Additional imaging and follow-ups are essential. The patient's pain was relieved with Korean medicine treatments, which suggests their potential application for stress fractures in RA patients.

Short Humeral Stems in Shoulder Arthroplasty

  • Oh, Hwang Kyun;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • 제21권2호
    • /
    • pp.105-110
    • /
    • 2018
  • Since the introduction of shoulder arthroplasty by Neer in 1974, the design of not only the glenoid component but also the humeral component used in shoulder arthroplasty has continually evolved. Changes to the design of the humeral component include a gradually disappearing proximal fin; diversified surface finishes (such as smooth, grit-blasted, and porous coating); a more contoured stem from the originally straight and cylindrical shape; and the use of press-fit uncemented fixation as opposed to cemented fixation. Despite the evolution of the humeral component for shoulder arthroplasty, however, stem-related complications are not uncommon. Examples of stem-related complications include intraoperative humeral fractures, stem loosening, periprosthetic fractures, and stress shielding. These become much more common in revision arthroplasty, where patients are associated with further complications such as surgical difficulty in extracting the humeral component, proximal metaphyseal bone loss due to stress shielding, intraoperative humeral shaft fractures, and incomplete cement removal. Physicians have made many attempts to reduce these complications by shortening the stem of the humeral component. In this review, we will discuss some of the limitations of long-stem humeral components, the feasibility of replacing them with short-stem humeral components, and the clinical outcomes associated with short-stemmed humeral components in shoulder arthroplasty.

하악골 과두경부 골절에 있어서 후하악부 절개법을 이용한 관혈적 정복술의 유용성 (Outcome of Open Reduction Via Retromandibular Approach for Mandibular Subcondyle Fracture)

  • 이형철;강동희;구상환;박승하
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.739-743
    • /
    • 2005
  • Subcondylar fractures have generally been treated by intermaxillary fixation except in cases where there is an absolute indication for open reduction. The reason behind a less aggressive surgical approach lies on the inherent difficulties in manipulating fragments in such a small area at the risk of damaging facial nerves or vessels such as the internal maxillary artery. However, long-term follow-up studies showed that conservative treatment of subcondylar fractures results in disturbances of occlusal function, deviation of the mandible, internal derangement of the temporomandibular joint, and ankylosis of the joint. We carried out open reduction of dislocated subcondylar fractures in 14 patients from 2000 to 2004 by a retromandibular approach. After the reduction of fractured bone, two H-shaped miniplates with 6 holes were fixed with screws at the anterior and posterior surfaces of the subcondyle. The retromandibular approach allowed good access and easy manipulation of the subcondyle. Immediate relief from malocclusion and correction of mandibular midline shifting were observed in all patients. Late temporomandibular dysfunction and ankylosis were not observed. Open reduction with plate osteosynthesis made it possible to avoid IMF in 7 of the 14 patients. The present study shows that open reduction through this retromandibular approach can produce good outcome in adult patients with subcondylar fracture.

The measurement of nose dimensions through the three-dimensional reformation images after nasal bone fracture

  • Jang, Seung Bin;Han, Dong Gil
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.31-36
    • /
    • 2019
  • Background: After closed reduction, patients are sometimes concerned that their external nasal shapes have changed. The aim of this study was to investigate and explain changes in nasal shape after surgery through objective photogrammetric anthropometry measurements taken through three-dimensional (3D) reformed computed tomography (CT) images. Methods: Our study included 100 Korean patients who underwent closed reduction of isolated nasal bone fracture from January 2016 to June 2017. Using the ruler tool in Adobe Photoshop CS3, we measured preoperative and postoperative nasal base heights, long nostril axis lengths, both nasal alar angles, and amount of nasal deviation through the 3D reformation of soft tissue via CT scans. We then compared the dimension of nose. Results: The amount of postoperative correction for nasal base height was 1.192 mm. The differences in nostril length between each side were found to be 0.333 mm preoperatively and 0.323 mm postoperatively. The differences in the nasal alar angle between each side was $1.382^{\circ}$ preoperatively and $1.043^{\circ}$ postoperatively. The amount of nasal deviation was found to be 5.248 mm preoperatively and 1.024 mm in postoperatively. Conclusion: After the reduction of nasal bone fractures, changes in nasal dimensions were noticeable in terms of nasal deviation but less significant in nasal tips, except for changes in nasal alar angles, which were notable.