• Title/Summary/Keyword: Long Tube

Search Result 614, Processing Time 0.03 seconds

Degradation of Carbon Steel Tube after Long Time Exposure at Petrochemical Plant (석유화확 Plant에서 장시간 사용된 튜브형태 탄소강의 열화현상)

  • Baik, Nam Ik
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.16-20
    • /
    • 2000
  • There have been little reports on the degradation of medium-carbon steel tubes served at high temperature for a long period. The purpose of this research was to provide the information of the proper replacement span of the tubes with the new ones. We investigated the medium-carbon steel tubes which were used at petrochemical plant for about 50,000 hrs to examine their mechanical properties and microstructures. Experimental results showed that the tubes satisfied the specification of ASTM despite such a long period of service, but mechanical properties, especially charpy impact values, were reduced. It concludes that the tubes on service at the plants needs a periodical inspection.

  • PDF

Cognitive Function and Activity of Daily Living of Older Adults Using Long-term Care Service (장기요양 이용 재가노인의 인지기능과 일상생활 능력)

  • Chang, Hyun-Sook;Lee, Hung Sa
    • Health Policy and Management
    • /
    • v.22 no.4
    • /
    • pp.522-537
    • /
    • 2012
  • The purpose of this study was to analyze the level of the cognitive function and activities of daily living of the beneficiary older adults at home based on Korean Long-term Care Insurance System. A cross-sectional descriptive survey was conducted from November 2010 to May 2011, the final respondents were 1,026 beneficiary older adults taking home visit care covered in Korean long-term care insurance system. The questionnaire included general characteristics of subjects, cognitive function, ADL(Activity of daily living). The data was analyzed using the SPSS 20.0 version. There was significant difference in cognitive function and ADL between 1st Grade, 2nd Grade and 3rd Grade of long-term care classification. The correlated factors of cognitive function were ADL, long-term care grade, disability of arm and leg, limitation of joint, bed sore and tube feeding. The correlated factors of ADL were cognitive function, long-term care grade, disability of arm and leg, bed sore and tube feeding. This study suggests that cognitive functions have to be mainly considered in long-term care grade. It is necessary to make an effort to develop long-term care grade in Korean long-term care insurance system an cognitive function improvement program for the beneficiary older adults. Above all things government will be seriously contemplating of revise contents for long-term care grade to provide quality of care for the older adults.

Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube (수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성)

  • Lee, Sang-Cheon;Park, Byeong-Deok;Han, Un-Hyeok;Lee, Jae-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

Effect of the Orifice Area Ratio on the Exit Flow of a Multi-Perforated Tube (다공튜브 오리피스 면적비 변화가 출구유동에 미치는 영향)

  • Lee, Sang-Kyoo;Lee, Jee-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.317-323
    • /
    • 2013
  • A multi-perforated tube indicates the existence of multiple holes of various shapes on the surface of a long cylinder-type or rectangular tube, and a hole installed on the surface is called an orifice, as it is relatively small in size, compared with the surface area of the tube. In this study, the flow characteristics of a circular multi-perforated tube with many orifices on the surface were investigated experimentally and numerically. The volume flowrate issuing from each orifice, discharge angle, effective flow area ratio, and the flow fields around the orifices were measured and visualized, with the variation of the orifice area ratio, at the same blockage ratio. The volume flowrate distributions along the flow direction of the multi-perforated tube tends to be more uniform, as larger orifices were positioned at the inlet side of the multi-perforated tube, compared with no orifice area change along the flow direction.

Steel and FRP double-tube confined RAC columns under compression: Comparative study and stress-strain model

  • Xiong, Ming-Xiang;Chen, Guangming;Long, Yue-Ling;Cui, Hairui;Liu, Yaoming
    • Steel and Composite Structures
    • /
    • v.43 no.2
    • /
    • pp.257-270
    • /
    • 2022
  • Recycled aggregate concrete (RAC) is rarely used in load-carrying structural members. To widen its structural application, the compressive behavior of a promising type of composite column, steel-fiber reinforced polymer (FRP) double-tube confined RAC column, has been experimentally and analytically investigated in this study. The objectives are the different performance of such columns from their counterparts using natural aggregate concrete (NAC) and the different mechanisms of the double-tube and single-tube confined concrete. The single-tube confined concrete refers to that in concrete-filled steel tubular (CFST) columns and concrete-filled FRP tubular (CFFT) columns. The test results showed that the use of recycled coarse aggregates (RCA) affected the axial load-strain response in terms of deformation capacity but such effect could be eliminated with the increasing confinement. The composite effect can be triggered by the double confinement of the steel and carbon FRP (CFRP) tubes but not by the steel and polyethylene terephthalate (PET) FRP tubes. The proposed analysis-oriented stress-strain model is capable to capture the load-deformation history of such steel-FRP double-tube confined concrete columns under axial compression.

A Study of Nurses' Perception of the Visiting Nursing Services of Long-term Care Insurance (노인장기요양보험 재가간호서비스에 대한 방문간호사의 인식)

  • Kwon, Min-Young;Lim, Ji-Young;Lee, Young-Whee;Kim, Hwa-Soon
    • Journal of Korean Public Health Nursing
    • /
    • v.24 no.1
    • /
    • pp.5-18
    • /
    • 2010
  • Purpose: The purpose of this study is to understand nurses' perception of visiting nursing services of long-term care insurance. Method: The descriptive survey study involved 188 nurses selected by the convenient sampling of visiting nurses who participated in professional education sessions. Results: Of the 188 participants, 149 (79.3%) were aware of long-term care insurance. Awareness of aspects of long-term care services was 78.7% for facility service, 77.7% for ordinary visiting care service, 85.1% for visiting nursing service and 77.7% for visiting bathing service. Concerning visiting nursing service provision, the majority of the study subjects considered nurse-aid not to be the appropriate route for delivery of services including nasogastric tube exchange, tracheostomy tube management and stitch removal. Conclusion: Continuous evaluation and research on the standards and requirements of the nursing workforce is needed to secure and maintain the high quality of visiting nursing services. Exhaustive studies concerning task division and workforce separation according to nursing services type and level of difficulty should be done to develop the appropriate job description for visiting nursing service staff.

A Study on Verification of NC Code of Multi-spindles Drilling for Tube Sheet in Heat Exchanger (열교환기 Tube Sheet의 다축드릴가공 검증에 관한 연구)

  • Oh, Byeong-Hwan;Lee, Hui-Gwan;Yang, Gyun-Ui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.79-83
    • /
    • 2001
  • A verification of multi-spindles drilling NC data is presented. The drilling of multi-spindles can offer productivity over three times as fast as that of single spindle. The most important things in machining tube sheet are precision of hole position and machining time. The drilling of multi-spindles has difficulties in controlling many motors to drive spindles and assign a correspondent number to each spindles. Multi-spindles drilling has different codes from CNC milling ; many subroutines, assignment of spindle, and so on. The conventional method, which inspects the NC code of the drilling, is to drill holes on a thin plate or tube sheet previously. The method results in low productivity because it consumed long machining time and welding for correction. This paper describes details of multi-spindles NC code and operation of multi-spindles drilling machine. A verification software of the multi-spindles drilling NC code is developed on the details.

  • PDF

Process analysis and prediction of die strength of condenser tube with 12 holes in hot extrusion (12홀 컨덴서 튜브의 열간 압출 공정해석 및 금형의 강도예측)

  • Lee S. H.;Jo H. H.;Kim B. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.436-439
    • /
    • 2005
  • Condenser tube has been used as a component of heat exchanger in automobile and air conditioning apparatus. In this paper, porthole die extrusion that is advantageous to form long hollow section tube is analyzed by direct extrusion of condenser tube with 12 holes. A study on extrusion process is performed through the 3D FE simulation at non-steady state and extrusion experiments. Especially, weldability, extrusion load and die defects were estimated try FE-simulation. This study present the redesigned die of direct extrusion in consideration of the results obtained from FE-analysis.

  • PDF

A Study on Optimum Shaft Alignment Analysis for VLCC (VLCC의 최적 축계정렬해석 연구)

  • Kim Hyu Chang;Kim Jun Gi
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.134-137
    • /
    • 2005
  • Recently, in VLCC, shafting system is stiffer due to large engine power whereas hull structure is more flexible due to scantling optimization, which can be suffered from alignment damage by incompatibility between shafting and hull, In this study, shafting system without stern tube forward bush was adapted for less sensitive system against external factors. Also, shaft alignment analysis was considered with hull deflection at various ship loading conditions and stern tube after bush of long journal bearing was evaluated by static squeezing pressure and dynamic oil film pressure with sloping control. Whirling vibration was also reviewed to avoid resonance with propeller blade order. So, reliable shafting design for VLCC could be achieved through optimized alignment analysis for the system without stern tube forward bush.

  • PDF

Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions (습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성)

  • Chang, Keun-Sun;Phan, Thanh-Long
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.