• Title/Summary/Keyword: Long Elbow

Search Result 147, Processing Time 0.02 seconds

Measurement on comfort range of korean population's joint motions for designing and evaluating workplaces

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.73-82
    • /
    • 1997
  • Daily exposure to constrained body postures and deviations from neutral postures over a long period may result in discomfort as well as pains and aches in the muscles, joints, tendons, and other soft tissues. Furthermore, it was known that poor body postures are a major cause of musculoskeletal disorders in industry. Therefore, in this study, comfort ranges of joint motions were obtained as a criterion for evaluating body postures and designing workplaces ergonomically, which were bases on subjects' perceived discomfort level estimated by magnitude estimation. Nineteen healthy male subjects participated in the laboratory study. They results showed that comfort ranges of joint motions occurred in the wrist, elbow, neck, and ankle were little less than their normal range of joint motions, but those in the back(L5/S1) and hip joint were much less than their normal ones. This fact implies that the back and jip movements are more stressful than the other joints movements. It is expected that comfort ranges of joint motions can be used as a valuable guideline when designing and evaluating workplaces.

  • PDF

Reverse Total Shoulder Arthroplasty: Early Outcome and Complication Report

  • Park, Yong-Bok;Jung, Sung-Weon;Ryu, Ho-Young;Hong, Jin-Ho;Chae, Sang-Hoon;Min, Kyoung-Bin;Yoo, Jae-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.68-76
    • /
    • 2014
  • Background: Recently, reverse total shoulder arthroplasty (RTSA) has been accepted as a main treatment option in irreparable massive rotator cuff tear with cuff arthropathy. The purpose of this study was to evaluate the early complication incidence and the preliminary clinical results of RTSAs performed in single institute. Methods: Fifty-seven RTSAs (56 patients) were performed between April 2011 and March 2013. The indications for RTSA were cuff tear arthropathy and irreparable massive rotator cuff tear with or without pseudoparalysis. Exclusion criteria were revision, preoperative infections and fractures. At final follow-up, 45 shoulders were enrolled. Mean follow-up duration was 12.5 months (range, 6-27 months). The mean age at the time of surgery was 73.6 years (range, 58-87 years). All the patients were functionally accessed via Constant score, American Shoulder and Elbow Surgeons (ASES) score, pain and functional visual analogue scale (VAS) scores and active range of motion. Complications were documented as major and minor. Major complications include fractures, infections, dislocations, nerve palsies, aseptic loosening of humeral or glenoid components, or glenoid screw problems. Minor complications include radiographic scapular notching, hematomas, heterotopic ossification, algodystrophy, intraoperative dislocations, intraoperative cement extravasation, or radiographic lucent lines of the glenoid. Results: The mean Constant score increased from 31.4 to 53.8 (p < 0.001). The pain and functional VAS scores improved (5.2 to 2.7, p < 0.001, 4.0 to 6.7, p < 0.001) and active forward flexion improved from $96.9^{\circ}$ to $125.6^{\circ}$ (p = 0.011). One or more complications occurred in 16 (35.6%) of 45 shoulders, with one failure (2.2%) resulting in the removal of implants by late infection. The single most common complication was scapular notching (9 [20%]). There were 4 (8.9%) axillary nerve palsies postoperatively (n=3: transient n. palsy, n=1: Symptom existed at 11 months postoperatively but improving). Conclusions: In a sort term follow-up, RTSA provided substantial gain in overall function. Most common early complications were scapular notching and postoperative neuropathy. Although overall early complication rate was as high as reported by several authors, most of the complications can be observable without compromise to patients' clinical outcome. Long term follow-up is required to clarify the clinical result and overall complication rate.

Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation - (성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교-)

  • Lee Young Kuk;Gu Hae Seo
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF

Short-Term Results of Subpectoral Tenodesis of the Proximal Biceps Tendon Using by Interference Screw (간섭나사를 이용한 흉근하 상완 이두근 건 고정술의 단기 추시 결과)

  • Kim, Jeong-Woo;Kang, Hong-Je
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Purpose: Our purpose was to retrospectively analyze clinical results of subpectoral tenodesis of the proximal biceps tendon using an interference screw. Materials and Methods: We reviewed 23 cases of patients receiving tenodesis of the proximal biceps tendon between January 2008 and January 2009 for whom we had follow-up data for at least 1 year. Twenty-three cases were operated on using subpectoral tenodesis; 16 of these cases had a rotator cuff tear. The results were judged using a visual analog scale (VAS), ASES, tenderness on the biceps groove, fixation failure and the degree of deformity (BAD). Results: VAS and ASES scores were significantly improved in all patients by the time of the final observation. There were no significant complications or fixation failures. The patients without a tear of the rotator cuff had a better result than patients with a tear of the rotator cuff, but the difference between the two groups was not significant (p>0.05). Conclusion: In patients with pathology of the long head of the biceps brachii, benefits of subpectoral interference screw tenodesis include pain relief, maintenance of functional biceps, muscle strength, and cosmesis. Subpectoral biceps tenodesis using interference screw fixation appears to be a promising, reproducible, reliable technique for addressing anterior shoulder pain related to pathology of the long head of the biceps brachii.

Arthroscopic Reconstruction of Bony Defect in Shoulder Instability (골 결손을 동반한 견관절 불안정성의 관절경적 재건술)

  • Kim, Yang-Soo;Ok, Ji-Hoon
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.117-124
    • /
    • 2011
  • Purpose: We reviewed arthroscopic reconstruction among the several treatment options for anterior shoulder instability with a bony Bankart lesion. Materials and Methods: Although open Bankart repair has long been considered the optimal surgical management of anterior shoulder instability, advancements in arthroscopic techniques have led to a recent shift to arthroscopic Bankart repair. However, for cases of a glenoid bony defect, several authors have reported various methods to accurately measure the amount of bony defect. Results: The arthroscopic technique of bony Bankart reconstruction continues to evolve and various methods have followed. To overcome the limitations of single fixation of a Bankart lesion, arthroscopic dual fixation (2 point fixation) has recently been tried to anatomically repair and restore the rigid fixation of a bony fragment. The concept of performing the Bristow-Latarjet transfer procedure under arthroscopy has also recently emerged. However, a large series of cases and long term follow up are required to prove the better results. Conclusion: To obtain a successful outcome for patients with anterior instability with a glenoid bony defect, it is imperative that the surgeon be aware of the accurate status of the bony defect and the intraoperative, postoperative factors associated with the proper treatment of this unstable pathology.

Evaluating the effects of age on the long-term functional outcomes following anatomic total shoulder arthroplasty

  • Troy Li;Akiro H. Duey;Christopher A. White;Amit Pujari;Akshar V. Patel;Bashar Zaidat;Christine S. Williams;Alexis Williams;Carl M. Cirino;Dave Shukla;Bradford O. Parsons;Evan L. Flatow;Paul J. Cagle
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.231-237
    • /
    • 2023
  • Background: In the past decade, the number of anatomic total shoulder arthroplasty (aTSA) procedures has steadily increased. Patients over 65 years of age comprise the vast majority of recipients, and outcomes have been well documented; however, patients are opting for definitive surgical treatment at younger ages.We aim to report on the effects of age on the long-term clinical outcomes following aTSA. Methods: Among the patients who underwent TSA, 119 shoulders were retrospectively analyzed. Preoperative and postoperative clinical outcome data were collected. Linear regression analysis (univariate and multivariate) was conducted to evaluate the associations of clinical outcomes with age. Kaplan-Meier curves and Cox regression analyses were performed to evaluate implant survival. Results: At final follow-up, patients of all ages undergoing aTSA experienced significant and sustained improvements in all primary outcome measures compared with preoperative values. Based on multivariate analysis, age at the time of surgery was a significant predictor of postoperative outcomes. Excellent implant survival was observed over the course of this study, and Cox regression survival analysis indicated age and sex to not be associated with an increased risk of implant failure. Conclusions: When controlling for sex and follow-up duration, older age was associated with significantly better patient-reported outcome measures. Despite this difference, we noted no significant effects on range of motion or implant survival. Level of evidence: IV.

A Content Analysis of Fashion Trends in Wedding Dresses - Using Wedding Dress Magazine, ′My Wedding′and ′She′s Bride′Issued in 1997 -

  • Lee, Mi-Yeon;Lee, Myoung-Hee
    • The International Journal of Costume Culture
    • /
    • v.2 no.2
    • /
    • pp.45-59
    • /
    • 1999
  • The objectives of this study were to identify fashion trend in the late 1990's by using content analysis of the design elements of wedding dresses in wedding magazine photographs. The data were selected among the wedding dress photographs in 1997 issues of two wedding's magazines, 'My wedding'and 'She's Bride'. The identified 455 photographs were classified into 15 major-categories of silhouettes, necklines, sleeves, materials, and trimmings, etc. 15 major-categories were consisted of 232 sub-categories. In the late 1990's, fashion trends of wedding dresses have mixed mainly dome silhouettes(56.0%), bell silhouettes, and tubular silhouettes. One-piece forms(90.8%) were familar more than two-piece forms. Necklines were used mainly such as square neckline(14.0%), high necklines(13.0) blended with other off-shoulder necklines, heart-shape necklines, and sweet-heart necklines, etc. Also camisole and strapless were added in neckline. Long-tight sleeves dominated at the late 1990's because that were used most (21.1%) among 22 sleeves sub-categories. And short sleeve, ruffled below-elbow length sleeves, and french sleeves were also used with the other sleeves. Long length in skirts(98.4%) were common but mini length were used rarely. Satin, lace, and solid cloth were the main materials in wedding dresses, however, spandex and velvet were also used. Various trimmings such as flowers(corsages), ribbons blended with embroidery, small flowers, buttons, frills, strings, and fur trimming are used. Especially, flowers used most(11.8%) among 61 trimmings sub-categories. But simplicity was shown in trimmings because there were dresses not having any decorations(14.3%). The wedding dress of the late 1990's has become more varied in design due to the reflection of changes in society and fashion of everyday garments while the traditional design of the wedding dress has been preserved.

  • PDF

A Study on the Changes of Shape for Children's Saenghwal Hanbok Jeogori (어린이 생활한복 저고리 형태의 변화양상에 관한 연구)

  • 정혜경;이미정
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.1
    • /
    • pp.75-87
    • /
    • 2003
  • The objectives of this study are to consider the shape for children's Saenghwal Hanbok and to analyze the trend up to date. Conclusions are described as follows: 1. Children's Saenghwal Hanbok was found in magazine about Hanbok from 1994. The design was various, for it was influenced by adult's Saenghwal Hanbok. From 1997, design of children's Saenghwal Hanbok was come to stay in a revival mood. 2. The Jeogori shape for children's Saenghwal Hanbok was as follows: Git was used several traditional git and western color from the initial to the recent period: Dong-Jeong was not attached in the initial period, but mostly attached with its ends sauare from 1997; Seop was not attached or transformed in the initial period, but attached in a traditional way (trapezoid-shaped) or a new way(rectangle-shaped) from 1998. The front was fastened on the right chest; the sleeves wert long or above-elbow or three quarter sleeve; Baerae was a curved shape in the initial period, but changed into a near-straight line with a slight curve; Jin-Dong line was straight for boys, but curve or not to be tot girls; Pocket was attached for boys, not attached for girls.

  • PDF

Effects of Constraint-Induced Movement Using Self-Efficacy Enhancing Strategies on the Upper Extremity Function of Chronic Hemiplegic Patients (자기효능증진전략을 이용한 건측억제유도운동이 편마비 환자의 상지기능에 미치는 효과)

  • Kang, Ji-Yeon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.2
    • /
    • pp.403-414
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effects of constraint-induced (CI) movement using self-efficacy on U/E function of chronic hemiplegic patients. CI movement discourages the use of the unaffected U/E, combined with intensive training of the affected U/E. Method: A non-equivalent pretest-posttest design was used. Study subjects were 40 hemiplegic patients conveniently selected from 2 different community health centers. The experimental subjects participated in the CI movement program for 6 hours daily over a period of two weeks. The exercises for affected U/E consisted of warming up, main exercise and ADL practice. To encourage the participants' behaviors self-efficacy enhancing strategies were used, which included performance accomplishment, vicarious experience, verbal persuasion and emotional arousal. Result: After 2 weeks of treatment, the grip power, pinch power, wrist flexion/extension, elbow flexion, and shoulder flexion/extension were significantly higher in the experimental subjects than in the control subjects. However, there was no significant difference in hand functions of the two groups. Conclusion: The above results show that the constraint-induced movement using self-efficacy could be an effective nursing intervention for improving U/E function of chronic hemiplegic patients. Long term studies are needed to determine the lasting effects of constraint-induced movement.

Seismic Capacity Test of Nuclear Piping System using Multi-platform Shake Table (다지점 진동대를 이용한 원자력발전소 배관계통의 내진성능실험)

  • Cheung, Jin-Hwan;Gae, Man-Soo;Seo, Young-Deuk;Choi, Hyoung-Suk;Kim, Min-Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.21-31
    • /
    • 2013
  • In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress (138 MPa) of the piping system even under the maximum excitation level of this test.