• Title/Summary/Keyword: Locus Method

Search Result 406, Processing Time 0.03 seconds

PI Controller Design Method by an Extension of Root-Locus Technique (확장된 근궤적법을 이용한 PI 제어기 설계 방법)

  • Kwon, Minhee;Chang, Hyuk-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.2
    • /
    • pp.126-132
    • /
    • 2016
  • The root-locus method is often employed when a controller is designed to find controller gain. It is usually used to determine one parameter gain while most controllers for industrial applications have more than one controller gain. For example PID controller has three controller gains, i.e. P, I, and D gains. Thus the conventional root-locus technique cannot complete the design of a controller with more than one controller gain. One way to overcome this drawback has been to apply the root-locus technique for one parameter while other parameters are assumed to be proportional to the parameter or to be constant. However this approach could lead to limited performance of the controller and if we try to adjust the proportional ratio or constants then it could be a long and tedious process of trial and error. Thus it is required to find an effective method for the root-locus technique to design controllers with more than one parameter. To this end this paper proposes an extended root-locus method for controllers with two parameters. In this paper Matlab is used as a computation tool to show the effectiveness of our method by solving examples numerically. As a result we obtained an extended root-locus illustrated in two-dimensional space for a control system with two parameters. The paper then presents how to find two controller gains based on this result of the extended root-locus. The main idea is that we can find the parameters by approaching the desired poles. It is expected that the proposed idea will help control engineers to easily design control systems using the root-locus technique, resulting in more accurate and faster control systems. Note that the extended root-locus idea can be applied to controller design problems with multiple parameters.

Development of an Impedance Locus Model for a Protective Relay Dynamic Test with a Digital Simulator

  • Kim, Soo-Nam;Lee, Myoung-Soo;Lee, Jae-Gyu;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.167-173
    • /
    • 2011
  • This paper presents a method for the development of the impedance locus to test the dynamic characteristics of protective relays. Specifically, using the proposed method, the impedance locus can comprise three impedance points, and the speed of impedance trajectory can be adjusted by frequency deviation. This paper is divided into two main sections. The first section deals with the configuration of impedance locus with voltage magnitude, total impedance magnitude, and impedance angle. The second section discusses the control of the locus speed with the means of the deviation between two frequencies. The proposed method is applied to two machine equivalent systems with offline simulation (i.e., PSCAD) and real-time simulation (i.e., real-time simulation environment) to demonstrate its effectiveness.

Whistleblowing Intention: Theory of Planned Behavior Perspectives

  • WAHYUNI, Lili;CHARIRI, Anis;YUYETTA, Etna Afri
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.335-341
    • /
    • 2021
  • This study aims to document empirically the individual factors that influence the intention to do whistleblowing. This study uses several variables, including internal locus of control, external locus of control, and whistleblowing intention. The use of the theory of Planned Behavior in this study is to explain and analyze the perception of behavior control as a determinant of whistleblowing intention. A quantitative research approach is used. The type of data in this study is primary data in the form of a questionnaire. The data collection method in this research is using the survey method. The sampling technique used a nonprobability sampling method, namely, the census method. The census method is the entire population sampled. The population in this study was all employees of the Pratama tax office in West Semarang. The research was conducted by distributing 111 questionnaires. Ninety-one valid questionnaires were returned appropriate for analysis. The data were processed using Partial Least Square-Structural Equation Modeling ((PLS-SEM) using the Warp PLS 7.0 program. WarpPLS 7.0 was used to test hypotheses and the relationship between variables. The study results showed that both internal locus of control and external locus of control affect whistleblowing intention.

A Study on the Camshaft Locus Analysis in a Camshaft Bearing (캠 축의 운동 궤적 해석에 관한 연구)

  • 지유철;조명래;정진영;최상현;한동철;최재권
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.167-175
    • /
    • 1997
  • The locus of a camshaft supported on camshaft bearings has been investigated using transient method. Forces applied to camshaft are composed of two components, one is transfer force between cam and tappet, the other is frictional force. These forces have been calculated using lumped mass model and EHL theory. ADI method has been used for numerical analysis of Reynolds equation, and 4th order Runge-Kutta method has been used for transient journal locus analysis. The effects of various load conditions are presented in the form of journal locus. As the result of analysis, it is found that camshaft bearings exist in the hydrodynamic lubrication condition.

  • PDF

An Analytical Study on Camshaft Locus at Camshaft Bearing in a Direct Acting OHC Valve Train System (직접 구동 OHC 밸브 트레인 캠 축의 운동 궤적 해석)

  • 지유철;조명래;정진영;최상현;한동철;최재권
    • Tribology and Lubricants
    • /
    • v.13 no.4
    • /
    • pp.53-59
    • /
    • 1997
  • The camshaft locus at camshaft beating in a direct acting OHC valve train system has been investigated using the transient method. Forces applied to the camsfiaft are composed of two components, one is the transfer force between the cam and the tappet, the other is the frictional force. These forces have been calculated using the lumped mass model and the elastohydrodynamic lubrication theory. The alternating direction implicit method has been used for the numerical analysis of Reynolds equation, and 4th order Runge-Kutta method has been used for the transient journal locus analysis. The effects of various load conditions are presented in the form of journal locus. As a result of the analysis, it has been found that camshaft bearings were mainly in the hydrodynamic lubrication condition.

Illumination Invariant Face Tracking on Smart Phones using Skin Locus based CAMSHIFT

  • Bui, Hoang Nam;Kim, SooHyung;Na, In Seop
    • Smart Media Journal
    • /
    • v.2 no.4
    • /
    • pp.9-19
    • /
    • 2013
  • This paper gives a review on three illumination issues of face tracking on smart phones: dark scenes, sudden lighting change and backlit effect. First, we propose a fast and robust face tracking method utilizing continuous adaptive mean shift algorithm (CAMSHIFT) and CbCr skin locus. Initially, the skin locus obtained from training video data. After that, a modified CAMSHIFT version based on the skin locus is accordingly provided. Second, we suggest an enhancement method to increase the chance of detecting faces, an important initialization step for face tracking, under dark illumination. The proposed method works comparably with traditional CAMSHIFT or particle filter, and outperforms these methods when dealing with our public video data with the three illumination issues mentioned above.

  • PDF

Distribution of Work Ethic factors, Locus of Control on Employee Performance

  • Asriati ASRIATI;Murtiadi AWALUDDIN;Agus SALIM HR;Mutakallim SIJAL
    • Journal of Distribution Science
    • /
    • v.22 no.7
    • /
    • pp.53-61
    • /
    • 2024
  • Purpose: This study aims to analyze distribution of work ethic factors in moderating the influence of Locus of Control on Employee Performance at PDAM (Regional Water Utility) Makassar City. Research design, data and methodology: The sample uses a purposive sampling method with a number sample as many as 35 respondents in PDAM Makassar City. The data collection method used is giving questionnaires to employees in accordance with the research conducted. Data analysis was carried out using multiple linear regression analysis tests and moderated regression analysis with an absolute difference value approach. Results: Locus of control has a positive and significant effect on employee performance and distribution of work ethics are able to moderate the influence of locus of control on employee performance in PDAM Makassar City. Conclusion: when locus of control increases it will be followed by an increase in employee performance, and also equal distribution of work ethic will strengthen the influence of locus of control on employee performance at PDAM Makassar City. Work ethic values that can be implemented include determining work ethic values, clear communication to evaluation and adjustment. The limitation of this research is that it only uses respondents from civil servants and needs further development.

Comparison of PFGE, IS6110-RFLP, and 24-Locus MIRU-VNTR for Molecular Epidemiologic Typing of Mycobacterium tuberculosis Isolates with Known Epidemic Connections

  • Jeon, Semi;Lim, Nara;Park, Sanghee;Park, Misun;Kim, Seonghan
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.2
    • /
    • pp.338-346
    • /
    • 2018
  • Two molecular epidemiologic methods, IS6110 restriction fragment length polymorphism (IS6110-RFLP) and 24-locus mycobacterial interspersed repetitive unit-variable-number tandem repeat (MIRU-VNTR), are used worldwide in studies of Mycobacterium tuberculosis (MTB). Conversely, because of its poor resolution, pulsed-field gel electrophoresis (PFGE) is not widely used for MTB. In this study, we improved the 24-locus MIRU-VNTR and PFGE protocols and compared the effectiveness of these approaches for the molecular typing of MTB using 75 clinical isolates obtained from a cohort investigation of high-risk populations infected with MTB. The 24-locus MIRU-VNTR method demonstrated superior discriminatory ability, followed by PFGE and IS6110-RFLP. Next, we analyzed six isolates with clear epidemiologic connections; that is, isolates from patients who attended the same school. IS6110-RFLP and PFGE identified these samples as the same type. By contrast, according to MIRU-VNTR, two isolates differed from four other isolates at one locus each; one isolate was identified as Mtub29 and the other as QUB-26. In summary, the 24-locus MIRU-VNTR assay was the most useful molecular typing method among the three methods investigated due to its discriminatory power, short time required, and availability as an epidemiologic investigation tool. PFGE was the second-best method. Compared with the other loci assessed in the 24-locus MIRU-VNTR assay, the Mtub29 and QUB-26 loci appeared to exhibit greater variability during transmission.

Development of Impedance Locus Model for Protective Relay Dynamic Test (보호 계전기 동특성 테스트를 위한 임피던스 궤적 모델 개발)

  • Kim, Su-Nam;Lee, Jae-Gyu;Lee, Myeong-Su;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.451-459
    • /
    • 2002
  • This paper presents a method for modelling of the impedance locus in order to test the protective relay with dynamic. This paper has the two parts, the first part is the configuration of impedance locus with voltage magnitude, total impedance magnitude and angle. And the second part is the control of the locus speed with deviation of two frequencies. The proposed method is applied to two machine equivalent system with PSCAD/EMTDC to show its effectiveness.

Analysis of the DNA Fingerprints from the Teeth -Using Chelex$^\textregistered$ 100 as a Medium of Simple Extraction of DNA from the Teeth- (치아에서의 DNA 유전자지문 분석 -Chelex$^\textregistered$ 100을 매개체로 한 DNA추출-)

  • Chang-Lyuk Yoon
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.515-528
    • /
    • 1995
  • The human genomic deoxyribonucleic acid(DNA) was extracted from the pulp, dentin of 22 teeth by clelex, phenol methods. Samples of the tooth-derived DNA were amplified by polymerase chain reaction(PCR), electrophosed for sex determination by detection of X-Y homologus amelogenin gene and D1S80 locus detection The following results have been achieved. 1. Chelex and phenol method are effective to sex determination in the pulp and dentin 2. Chelex method is not suitable for detection of D1S80 locus. 3. Concentration and purity of DNA for teeth using chelex method is lower than using phenol method. From the above investigation, chelex method is simple, rapid for sex determination, but it is not suitable for detection of VNTRs.

  • PDF