• Title/Summary/Keyword: Location estimation

Search Result 1,216, Processing Time 0.023 seconds

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

Studies on the ecological variations of rice plant under the different seasonal cultures -II. A study on the year variations and prediction of heading dates of paddy rice under the different seasonal cultures- (재배시기 이동에 의한 수도의 생태변이에 관한 연구 -II. 재배시기 이동에 의한 수도출수기의 년차간변이와 그 조기예측-)

  • Hyun-Ok Choi
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.3
    • /
    • pp.41-48
    • /
    • 1965
  • This study was aimed at knowing the magnitude of year variation in rice heading dates under the different seasonal cultures, and to estimate the heading date in advance. Using six rice varieties such as Kwansan, Suwon#82, Suwon #144, Norin#17, Yukoo#132 and Paltal, the early, ordinary and late seasonal cultures had been carried out at Paddy Crop Division, Crop Experiment Station at Suwon for the six-year period 1959 to 1964. In addition the data of the standard rice cultures at the Provincial Offices of Rural Development for the 12-year period 1953 to 1954, were analyzed for the purpose of clarifying a relationship between variation of rice heading dates and some of meteorological data related to the locations and years. The results of this study are as follows: 1. Year variation of rice heading dates was as high as 14 to 21 days in the early seasonal culture and 7 to 14 days in the ordinary seasonal culture, while as low as one to seven days in the late seasonal culture which was the lowest among three cultures. The magnitude of variation depended greatly on variety, cultural season and location. 2. It was found out that there was a close negative correlation between the accumulated average air temperature for 40 days from 31 days after seeding and number of days to heading in the early seasonal culture. Accordingly, it was considered possible to predict the rice heading date through calculation of the accumulated average air temperature for the above period and then the linear regression(Y=a+bx). On the other hand, an estimation of the heading date in the late seasonal culture requires for the further studies. In the ordinary seasonal culture, no significant correlation between the accumulated average air temperature and number of days to heading was obtained in the six-year experiments conducted at Suwon. There was a varietal difference in relationship between the accumulated average air temperature for 70 days from seeding and number of days to heading in the standard cultures at the provincial offices of rural development. Some of varieties showed a significant correlation between two factors while the others didn't show any significant correlation. However, there was no regional difference in this relationship.

  • PDF

Computerized Quantative Analysis of Cornary Angiogram in Patients without Coronary Pathology (Computer System을 이용한 정상 관상동맥 조영 사진의 양적분석)

  • Yun, Yang-Koo;Park, Kay-Hyun;Choi, Young-Soo;Kim, Kwhan-mien;Jun, Tae-Gook;Kim, Jhin-gook;Shim, Young-Mog;Park, Pyo-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.488-493
    • /
    • 1998
  • In the preoperative evaluation before coronary artery bypass surgery, review of the coronary arteriogram is the most important step. Expected "normal" lumen diameter at a given coronary anatomic location is a basis for quantative estimation of coronary disease severity that could be more useful than the traditional "percent stenosis". The distribution and number of major coronary artery branches are determinants of number of bypass grafts needed. We reviewed the coronary artery anatomy in 174 adult patients who revealed no coronary pathology in angiographic studies done from September 1994 to June 1996. Quantative analysis was done in all cases by a single person using a Computerized System (Arripro 35ⓡ). The results were follows; 1) The mean diametre of left main coronary artery was 4.45 mm(range 2.74~6.72). The pattern of branching was bifurcation in 67.24%, trifurcation in 28.74% and quadrifurcation in 4.02% of the patients. 2) The mean diametre of left anterior descending artery was 3.17 mm(range 2.10~5.85), 2.79 (range 1.55~5.59) and 2.17 mm(range 1.37~3.81) in the proximal, mid, and the distal portions, respectively. The number of diagonal branches of left anterior artery was from one to four(mode=2). 3) The mean diametre of proximal and distal left circumflex artery were 3.17mm(range 1.74~4.89) and 2.19 mm(range 1.21~4.46). The number of obtuse marginal branches of left circumflex artery is from one to six(mode 2). 4) The mean diametre of proximal and distal right coronary artery, the posterior descending artery and the largest posterolateral branch were mean 3.51 mm(range 2.07~5.67), 2.09 mm (range 1.42~3.60), 2.09 mm(range 1.02~3.60) and 2.30 mm(range 1.39~4.39). 5) The right coronary artery dominant was 163 cases(93.68%) of the total 174 cases. 6) The large significant acute marginal artery was visualized in more than half of the people. half of the people.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Traces of Gwan-a in Yanggeun and Jipyeong in Literature - with the Focus on the History, Scale and Sites of Gwan-a - (문헌으로 찾은 양근·지평 관아의 흔적 - 관아의 연혁·규모·터[址]를 중심으로 -)

  • Yu, Dong-Ho
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.1
    • /
    • pp.80-99
    • /
    • 2018
  • In premodern society, the central spaces in local counties were known as Eupchi (邑治), in which Gwan-a (官衙). The Eupchi located in seaside counties were in Eupseong, whereas the Eupchi of inland counties only included a Gwan-a, and did not have a fortress. Yanggeun-gun (楊根郡) and Jipyeonghyeon (砥平縣), which currently form Yangpyeong-gun (楊平郡), were counties where only Gwan-a existed. At present, there are few traces of the Gwan-a in Yanggeun and Jipyeong. In addition, it is impossible to exactly verify the history, scale and location of these two Gwan-as. Therefore, this study attempts to make a rough estimation of the histories, scales and sites of these Gwan-a by analyzing the relevant literature and ancient maps that are scattered according to the principles of spatial organization of local Gwan-a. The Yanggeun and Jipyeong Gwan-a appear to have been built in the early Joseon period. There are three reasons for this assertion: First, in Yanggeun and Jipyeong, Suryeong (守令) were first officially appointed after the early Joseon period. Once Suryoeng were appointed to such counties, the Gwan-a in which they would serve could be established. Second, the Dongheon (東軒) in Yanggengun and the Gaeksa (客舍) in Jipyeonghyeon were rebuilt in 1703 (29th year of the reign of King Sukjong) and 1465 (11th year of the reign of King Sejo), respectively; thus; the Gwan-a must have existed since the early Joseon period.. Third, in Yanggeungun, the Hyanggyo (鄕校) had existed since the early Joseon period, as the Joseon government necessarily established the Hyanggyo in areas where Suryeong were established. The facilities of local Gwan-a in the Joseon period were largely divided into gonghae (公?), educational institutes, and alters. The gonghae was a facility in which the Suryeong and Gwanwon (官員) managed administrative, judicial and military affairs, and consisted of the A-sa (衙舍), Hyeongcheong (鄕廳), Jackcheong (作廳), Gaeksa (客舍), Gungwancheon (軍官廳), and so on. The education institute was called a Hyeonggyo, while alters included the Sajikdan (社稷壇), Seonghwansa (城隍祠) and Yeodan (?壇). Both the Yeongeun and Jipyeong Gwan-a also consisted of such facilities as A-sa, Hyangcheong, Jakcheong, Gaeksa, Gungwancheong, Hyeonggyo, Changgo, Sajikdan, Seonghwangsa, Yeodan, Saryeongcheong, Jiincheong and Gwannocheong. The present sites for both Gwan-as cannot be identified with any certitude. However, they can be roughly identified by connecting the related literatures, oral statements and relics with the principles of spatial organization of local Gwan-a in the Joseon period. ${\bullet}$ Address of the Yanggeun A-sa (Dongheon): the whole of # 15, Gwanmun 1-gil, Yangpyeong-eup (Yanggeun-ri 151) in front of Yanggeun Junior High School at present. ${\bullet}$ Address of Yanggeun Gaeksa: around the Yangpyeong police station at present. ${\bullet}$ Address of Jipyeong A-sa(Dongheon): the whole of Jipyeong-ri 248-250, Jipyeong-myeon at present. ${\bullet}$ Address of Jipyeong Gaeksa: the whole of Jipyeong-ri 238, Jipyeong-myeon at present.

A Study on the Design of the Grid-Cell Assessment System for the Optimal Location of Offshore Wind Farms (해상풍력발전단지의 최적 위치 선정을 위한 Grid-cell 평가 시스템 개념 설계)

  • Lee, Bo-Kyeong;Cho, Ik-Soon;Kim, Dae-Hae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.848-857
    • /
    • 2018
  • Recently, around the world, active development of new renewable energy sources including solar power, waves, and fuel cells, etc. has taken place. Particularly, floating offshore wind farms have been developed for saving costs through large scale production, using high-quality wind power and minimizing noise damage in the ocean area. The development of floating wind farms requires an evaluation of the Maritime Safety Audit Scheme under the Maritime Safety Act in Korea. Floating wind farms shall be assessed by applying the line and area concept for systematic development, management and utilization of specified sea water. The development of appropriate evaluation methods and standards is also required. In this study, proper standards for marine traffic surveys and assessments were established and a systemic treatment was studied for assessing marine spatial area. First, a marine traffic data collector using AIS or radar was designed to conduct marine traffic surveys. In addition, assessment methods were proposed such as historical tracks, traffic density and marine traffic pattern analysis applying the line and area concept. Marine traffic density can be evaluated by spatial and temporal means, with an adjusted grid-cell scale. Marine traffic pattern analysis was proposed for assessing ship movement patterns for transit or work in sea areas. Finally, conceptual design of a Marine Traffic and Safety Assessment Solution (MaTSAS) was competed that can be analyzed automatically to collect and assess the marine traffic data. It could be possible to minimize inaccurate estimation due to human errors such as data omission or misprints through automated and systematic collection, analysis and retrieval of marine traffic data. This study could provides reliable assessment results, reflecting the line and area concept, according to sea area usage.