• Title/Summary/Keyword: Location coefficient

Search Result 493, Processing Time 0.026 seconds

The Time of Concentration Considering the Rainfall Intensity (강우강도를 고려한 도달시간 산정식)

  • Yoo, Dong-Hoon;Kim, Jong-Hee;Lee, Min-Ho;Lee, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.7
    • /
    • pp.591-599
    • /
    • 2011
  • The rainfall intensity is a very essential factor which must be considered for the estimation of the time of concentration. The rainfall intensity, however, is not fully considered for the estimation of the time of concentration due to the complexity of the equation of rainfall intensity. To increase accuracy of the time of concentration, the rainfall intensity and return period were included in the derivation of the time of concentration equations in this study. The equation of rainfall intensity is Sherman type and the regional coefficients were estimated from the rainfall intensity readings on the probability rainfall maps published by Ministry of Construction and Transportation. For simple calculation of rainfall intensities, the contour maps were drawn that expresses coefficients of the Sherman type equation. By substituting the Sherman type equation of rainfall intensity in the equation of the time of concentration, a relatively simple equation with no repeated calculation has been derived. From the study results, in order to include the influence of the rainfall intensity for the estimation of the time of concentration, it is highly recommended that the Sherman type equation of rainfall intensity be used. When one knows a location in Korea and a return period, he can estimate the coefficients of the rainfall intensity equation and calculate the time of concentration considering the rainfall intensity.

An Optimum Scale for Topoclimatic Interpolation of Daily Minimum Temperature in Complex Terrain (일 최저기온 공간내삽을 위한 지형기후학적 최적 공간규모)

  • 정유란;서희철;윤진일;이광회
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.4
    • /
    • pp.261-265
    • /
    • 2003
  • Cold air accumulation plays a critical role in formulating daily minimum temperature in complex terrain on radiative cooling nights, and spatial interpolation can be improved by accommodating this important topoclimatic variable. Little is known about the spatial scale for computing cold air accumulation which influences daily minimum temperature. Air temperature was measured at 10-minute intervals during September 2002- February 2003 at eight locations within a 1 by 1 km hilly orchard area. Minimum temperature data for suspected radiative cooling nights were collected, and the deviations from reference observations at a near-by KMA automated weather station were calculated. A digital elevation model with a 10m cell size was used to calculate the cold air accumulation at 8 locations. Zonal averages of the cold air accumulation were computed for each location by increasing the cell radius from 1 to 10. Temperature deviations were regressed to a common logarithm of the smoothed averages of cold air accumulation to derive a linear relationship between the local temperature deviation and the site topography. The highest coefficient of determination ($r^2$ = 0.78) was found at a cell radius of 5, which corresponds to an approximately 1 ha boundary surrounding the point of interest.

A study on simulation modeling of the underground space environment-focused on storage space for radioactive wastes (지하공간 환경예측 시뮬레이션 개발 연구-핵 폐기물 저장공간 중심으로)

  • 이창우
    • Tunnel and Underground Space
    • /
    • v.9 no.4
    • /
    • pp.306-314
    • /
    • 1999
  • In underground spaces including nuclear waste repository, prediction of air quantity, temperature/humidity and pollutant concentration is utmost important for space construction and management during the normal state as well as for determining the measures in emergency cases such as underground fires. This study aims at developing a model for underground space environment which has capabilities to take into account the effects of autocompression for the natural ventilation head calculation, to find the optimal location and size of fans and regulators, to predict the temperature and humidity by calculating the convective heat transfer coefficient and the sensible and latent heat transfer rates, and to estimate the pollutant levels throughout the network. The temperature/humidity prediction model was applied to a military storage underground space and the relative differences of dry and wet temperatures were 1.5 ~ 2.9% and 0.6 ~ 6.1%, respectively. The convection-based pollutant transport model was applied to two different vehicle tunnels. Coefficients of turbulent diffusion due to the atmospheric turbulence were found to be 9.78 and 17.35$m^2$/s, but measurements of smoke and CO concentrations in a tunnel with high traffic density and under operation of ventilation equipment showed relative differences of 5.88 and 6.62% compared with estimates from the convection-based model. These findings indicate convection is the governing mechanism for pollutant diffusion in most of the tunnel-type spaces.

  • PDF

Water Quality Analysis in Nakdong River Tributaries for the Determination of Priority Management Areas (관리 우선순위 선정을 위한 낙동강 지류·지천 지점의 수질 오염 특성 분석)

  • Im, Tae Hyo;Na, Seungmin;Shin, Sangmin;Son, Younggyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.10
    • /
    • pp.558-565
    • /
    • 2016
  • Water quality data including flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations in Nakdong river tributaries were analyzed to determine priority management areas using 699 data sets from 195 locations in 2015. It was pointed out that the coefficients of variation, the ratio of the standard deviation to the mean, for the concentrations and loading rates of BOD, T-P, and TOC in each monitoring location were so large that average values of water quality monitoring data might be not appropriate to determine the priority management areas among all 195 monitoring stations in Nakdoing river. Therefore we suggested two evaluation methods using each water quality data independently. In the first method the excess numbers of the BOD, T-P, and TOC concentrations comparing to the water quality standards in the medium-sized management areas in Nakdong river was evaluated for each monitoring station. In the second method the percentile ranks of the loading rates of the BOD, T-P, and TOC were obtained for each monitoring data. The two groups of the priority management areas determined by each method were compared and the water quality characteristics in Nakdoing river were investigated.

A Study on Continuous long-term Wave Observation using Remote Monitoring System (원격모니터링을 이용한 연속파랑관측에 관한 연구)

  • Shin, Bumshick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.654-659
    • /
    • 2018
  • In this study, continuous long-term observation is implemented with an ocean radar. Ocean radar conducts remote observation (combined) with ground-based radars, which enable a series of simultaneous observations of an extensive range of the coast with high frequency. An ocean radar for continuous long-term observation is operated at Samcheok on the east coast of Korea. Samcheok experienced tsunami damage in recent years and is the location of a nuclear power plant. In order to examine the reliability of the ocean radar, a pressure-type wave gauge, ultrasonic wave gauge, and ocean buoy are installed for the purpose of data comparison and verification. The ocean radar used in this study is an array-type HF-RADAR named WERA (WavE RAdar). The analysis of the data obtained from continuous long-term observations showed that the radar observations were in agreement with more than 90% of the wave data collected within a 25 km range from the center of two sites. Less than 1% of the entire observation data was unmeasured by the time series analysis. As a result of comparing the radar data with the direct observations made by the wave gauge, it was inferred that the RMS deviation is less than 20cm and the correlation coefficient was in the range of 0.84 ~ 0.87. Moreover, supported by such observations, a comprehensive monitoring system is being developed to provide the public with real-time reports on waves and currents via the internet.

Evaluation of Stream Depletion from Groundwater Pumping in Deep Aquifer Using An Analytical Model (해석적 모형을 이용한 심부대수층 지하수 양수로 인한 하천수 감소량 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.769-777
    • /
    • 2016
  • The objective of this study was to evaluate the stream depletion from groundwater pumping in deep aquifer using the Ward and Lough's analytical solution (2011) which considers a two-layer leaky aquifer system. The calculated results for each pumping from the 110 wells beside streams showed a wide range of non-dimensional stream depletion, that is the streamflow depletion rate divided by the groundwater pumping rate, from lower than 0.1 to more than 0.9 on average for 5 years depending on the specific properties of well location. From the comparison with Hunt's solution (1999) of a single layer aquifer, the Ward and Lough's solution showed about 50% lower than the Hunt's solution due to the difference of hydraulic properties between the first and second layers as well as the lagged effect of vertical leakance. It was also found that the groundwater pumping has a minor effect on the stream depletion if the stream depletion factor (SDF) of the 1st layer is higher than about 1,000 or the SDF of the 2nd layer is higher than about 100, or the vertical leakance is smaller than $10^{-5}s^{-1}$. Furthermore, in the present study, the variations of the stream depletion were assessed according to the magnitude of unmeasured hydraulic properties such as transmissivity and storage coefficient of the 1st layer, vertical hydraulic conductivity of the 2nd layer, the streambed hydraulic conductance.

The Converging Effects of Complete Science Subjects in High School on the Grades of Basic Nursing Sciences and Major Nursing Subjects of Nursing Students of one University (고등학교 과학과목 이수가 일 대학 간호학생의 기초간호과학 및 전공간호학성적에 미치는 융합적 효과)

  • Jung, In-Sook
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.5
    • /
    • pp.97-106
    • /
    • 2016
  • This study is to find the converging effects of the Complete Sciences Subjects(CSS) in high school before entrance to University on the scores of Basic Nursing Sciences(BNS) and Major Nursing Subjects(MNS) of 111 senior nursing students of one university. Using the SPSS 19.0, t-test, Pearson's correlation coefficient, multiple and simple linear regression were carried out. The mean scores of the groups that have completed the subjects of Biology I & II, Chemistry I & II were high on Anatomy, Physiology and Pathology. There was a significant difference between the group of completed Biology II and incompleted Biology II on the mean scores of MNS(p<.05). There were positive correlations between the CSS and the scores of BNS and MNS, a moderate correlation between Chemistry II and BNS(r=.303) and a strong correlation between BNS and MNS(r=.796). Explanation rate of CSS on the scores of BNS, and MNS were 18.2%, 8.2% respectively, and on the scores of BNS on MNS was 63.8%. The result of this study can be used in assessing university entrance procedure after repeated study, extended location and more participants, and to use for making pre-school program for the freshmen who didn't CSS.

A Study on the Evaluation of Smear Zone by In-situ Tests (현장시험에 의한 Smear Zone의 평가)

  • 이장덕;구자갑
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.207-216
    • /
    • 2003
  • To evaluate the smear zone caused by the drain installation, 10 piezometers were installed in the typical soft ground in the western coastal area of Korea. The dynamic pore water pressure developed during the drain installation was monitored using piezometers installed at a distance of 10cm, 20cm, 30cm, 40cm and 50cm from the location of the drain. The decay of pore pressure with time after pushing piezometers to depths of 5 meters and 7 meters during the drain installation was monitored to assess flow and consolidation characteristics of the soil after disturbance of the soil due to the drain installation. The drain installation results in shear strain and displacement of the soil and it decreases the permeability of the soil. Hence, the comparison between dissipation of the pore water pressure process in 10 pieszometers before as well as after installation of the drain indicated the diameter of disturbance zone and smear zone, which is related to the cross-sectional dimension of the mandrel. In addition, Cone-pressuremeter(CPM) tests were performed to obtain rigidity index of the soil for an interpretation of the dissipation processes. It has been evaluated by in-situ tests that the smear zone is from 3.0 to 3.6 times of the cross-sectional dimension of the mandrel. The hydraulic conductivity expressed in terms of the coefficient of consolidation after the drain installation was calculated from 3 to 8 times decrease evaluated by Teh & Houlsby equation and CPM test results.

Geological and Geophysical Characteristics of the New Hebrides Basin (뉴헤브리디스 해분의 지질.지구물리학적 특징에 관한 연구)

  • Park, Chung-Hwa
    • Journal of the Korean earth science society
    • /
    • v.18 no.6
    • /
    • pp.559-564
    • /
    • 1997
  • The New Hebrides Basin is an inactive non back-arc basin located at the convergent boundary of the Pacific and Info-Australian plates. This basin was formed from 46 Ma to 60 Ma. The basin has two spreading episodes with rates of 34 mm/a for 42 to 47 Ma and 17 mm/a for 47 to 60 Ma. The sediments covered in the basin has uniform thickness of 0.65 sec. The age-depth correlation curve of the New Hebrides Basin can be represented by the following equation: $Depth(m)=2689+312\sqrt{Age}(Ma)$ The coefficient of 312 in this equation is close to that for major oceans, 350. This suggests that the cooling processes of the lithospheres in the New Hebrides Basin and major oceans are similar to each other. Free-air gravity anomalies of the basin varying from -22.3 mgal to +59.0 mgal. The mean value is +30.2 mgal higher than those of the normal oceans. Moderately large free-air gravity anomalies in the New Hebrides Basin are presumably owing to its location on a marginal swell along the New Hebrides Trench. It is generally observed that the ocean floor is very gently uplifted in a zone about 200 km oceanward of the trench axis. Positive free-air gravity anomalies amounting to $50{\sim}60$ mgal are usually observed on the crest of the swell. This topography is presumably by bending of the oceanic lithosphere so as to dynamically maintain nonisostatic states for some duration.

  • PDF

Evaluation on Air Quality inside Subway Driver Cabin by Monitoring PM, $CO_2$, and CO Levels (서울 일부 지하철 승무원석의 PM, 이산화탄소, 일산화탄소 모니터링에 의한 실내 공기질 특성 평가)

  • Kwag, Hyun-Suk;Jin, Ku-Won;Kim, Won;Yang, Won-Su;Choi, Sang-Jun;Park, Dong-Uk
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.379-386
    • /
    • 2005
  • [ $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ ] in driver cabins of subway line from 5 to 8 were monitored from 07:00 through 21:00 (or 19:30 or 20:00) on May. Driver cabin of subway line 7 showed the highest $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ concentrations. General Linear Model indicated that subway line, subway location (ground and underground track) and running time (morning and afternoon) significantly influenced the concentrations of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ (p=0.000). Daily profile of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$, expressed as an 30 minutes average, showed similar variation pattern over day period. These concentrations showed the highest concentrations between 07:00 and 09:00 of rush hour, slightly dropped and again rose slightly after 18:00. In correlation analysis, significant relations among $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ were detected (p<0.01). In particular, correlation coefficient between $PM_{10}\;and\;PM_{2.5}$ was highly significant (r=0.884). Regression analysis also concluded that $PM_{10}$ concentration significantly explained 71.4% of variation of $PM_{2.5}$ concentration (p=0.000, $R^2=0.714$). Correlations by CO with $PM_{10}\;and\;PM_{2.5}$ were 0.451 and 0.520, which were higher than those by $CO_2$. Further study is needed to examine the sources of $PM_{2.5}$ and CO in subway and to compare pollutants concentration among subway lines.