• 제목/요약/키워드: Location and scale parameters

검색결과 133건 처리시간 0.02초

Risk Factors and Preoperative Risk Scoring System for Shunt-Dependent Hydrocephalus Following Aneurysmal Subarachnoid Hemorrhage

  • Kim, Joo Hyun;Kim, Jae Hoon;Kang, Hee In;Kim, Deok Ryeong;Moon, Byung Gwan;Kim, Joo Seung
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.643-648
    • /
    • 2019
  • Objective : Shunt-dependent hydrocephalus (SdHCP) is a well-known complication of aneurysmal subarachnoid hemorrhage (SAH). The risk factors for SdHCP have been widely investigated, but few risk scoring systems have been established to predict SdHCP. This study was performed to investigate the risk factors for SdHCP and devise a risk scoring system for use before aneurysm obliteration. Methods : We reviewed the data of 301 consecutive patients who underwent aneurysm obliteration following SAH from September 2007 to December 2016. The exclusion criteria for this study were previous aneurysm obliteration, previous major cerebral infarction, the presence of a cavum septum pellucidum, a midline shift of >10 mm on initial computed tomography (CT), and in-hospital mortality. We finally recruited 254 patients and analyzed the following data according to the presence or absence of SdHCP : age, sex, history of hypertension and diabetes mellitus, Hunt-Hess grade, Fisher grade, aneurysm size and location, type of treatment, bicaudate index on initial CT, intraventricular hemorrhage, cerebrospinal fluid drainage, vasospasm, and modified Rankin scale score at discharge. Results : In the multivariate analysis, acute HCP (bicaudate index of ${\geq}0.2$) (odds ratio [OR], 6.749; 95% confidence interval [CI], 2.843-16.021; p=0.000), Fisher grade of 4 (OR, 4.108; 95% CI, 1.044-16.169; p=0.043), and an age of ${\geq}50years$ (OR, 3.938; 95% CI, 1.375-11.275; p=0.011) were significantly associated with the occurrence of SdHCP. The risk scoring system using above parameters of acute HCP, Fisher grade, and age (AFA score) assigned 1 point to each (total score of 0-3 points). SdHCP occurred in 4.3% of patients with a score of 0, 8.5% with a score of 1, 25.5% with a score of 2, and 61.7% with a score of 3 (p=0.000). In the receiver operating characteristic curve analysis, the area under the curve (AUC) for the risk scoring system was 0.820 (p=0.080; 95% CI, 0.750-0.890). In the internal validation of the risk scoring system, the score reliably predicted SdHCP (AUC, 0.895; p=0.000; 95% CI, 0.847-0.943). Conclusion : Our results suggest that the herein-described AFA score is a useful tool for predicting SdHCP before aneurysm obliteration. Prospective validation is needed.

결합된 파라메트릭 활성함수를 이용한 완전연결신경망의 성능 향상 (Performance Improvement Method of Fully Connected Neural Network Using Combined Parametric Activation Functions)

  • 고영민;이붕항;고선우
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 2022
  • 완전연결신경망은 다양한 문제를 해결하는데 널리 사용되고 있다. 완전연결신경망에서 비선형활성함수는 선형변환 값을 비선형 변환하여 출력하는 함수로써 비선형 문제를 해결하는데 중요한 역할을 하며 다양한 비선형활성함수들이 연구되었다. 본 연구에서는 완전연결신경망의 성능을 향상시킬 수 있는 결합된 파라메트릭 활성함수를 제안한다. 결합된 파라메트릭 활성함수는 간단히 파라메트릭 활성함수들을 더함으로써 만들어낼 수 있다. 파라메트릭 활성함수는 입력데이터에 따라 활성함수의 크기와 위치를 변환시키는 파라미터를 도입하여 손실함수를 최소화하는 방향으로 최적화할 수 있는 함수이다. 파라메트릭 활성함수들을 결합함으로써 더욱 다양한 비선형간격을 만들어낼 수 있으며 손실함수를 최소화하는 방향으로 파라메트릭 활성함수들의 파라미터를 최적화할 수 있다. MNIST 분류문제와 Fashion MNIST 분류문제를 통하여 결합된 파라메트릭 활성함수의 성능을 실험하였고 그 결과 기존에 사용되는 비선형활성함수, 파라메트릭 활성함수보다 우수한 성능을 가짐을 확인하였다.

광섬유센서를 이용한 쓰레기 이송관로의 장기 계측시스템 구축을 위한 실험적 연구 (Experimental Study for Establishment of Long-term Monitoring System using Fiber Optical Sensor for Pipeline System for Waste Transportation)

  • 김행배;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.35-43
    • /
    • 2016
  • 최근 지속적으로 증가하는 생활폐기물의 배출과 처리가 사회적인 문제로 대두됨에 따라 새로운 폐기물의 수거 및 운반방식으로 쓰레기 이송관로시스템이 최근 부각되고 있다. 이러한 이송관로시스템은 긴 연장을 갖기 때문에 이송관로에 문제가 발생할 경우 즉각적으로 해당 위치를 파악하여 조치할 수 있는 적절한 장기계측시스템을 적용하는 것이 필요하다. 본 연구에서는 FBG 광섬유 변형률 센서를 이용한 계측시스템의 적용성을 검토하고, 이를 이용한 최적의 계측시스템을 도출할 수 있는 자료를 확보하기 위한 실험적 연구로서, 이송관로에 발생할 수 있는 대표적인 손상유형으로 압력누출, 관로변형 및 관로폐색의 3가지 현상을 실제규모의 모형 이송관로실험체에 모사한 후 관로에 설치된 FBG센서로부터 응답을 측정하였다. 실험결과를 바탕으로 실험변수로 적용한 각각의 손상유형에 따른 효과적인 센서설치 방법과 배치방법을 도출하였다. 특히 관로변형실험 결과는 변형발생지점으로부터의 센서와의 거리에 따른 응답 상관관계를 통해 센서배치간격을 산출하여 FBG센서를 이용한 계측설계를 수행하였다.