Experimental and numerical studies on the behaviour of corroded cold-formed steel columns

  • Nie, Biao;Xu, Shanhua;Zhang, Haijiang;Zhang, Zongxing
    • Steel and Composite Structures
    • /
    • v.35 no.5
    • /
    • pp.611-625
    • /
    • 2020
  • Experimental investigation and finite element analysis of corroded cold-formed steel (CFS) columns are presented. 11 tensile coupon specimens and 6 stub columns of corroded CFS that had a channel section of C160x60x20 were subjected to monotonic tensile tests and axial compression tests, respectively. The degradation laws of the mechanical properties of the tensile coupon specimens and stub columns were analysed. An appropriate finite element model for the corroded CFS columns was proposed and the influence of local corrosion on the stability performance of the columns was studied by finite element analysis. Finally, the axial capacity of the experimental results was compared with the predictions obtained from the existing design specifications. The results indicated that with an increasing average thickness loss ratio, the ultimate strength, elastic modulus and yield strength decreased for the tensile coupon specimens. Local buckling deformation was not noticeable until the load reached about 90% of the ultimate load for the non-corroded columns, while local buckling deformation was observed when the load was only 40% of the ultimate load for the corroded columns. The maximum reduction of the ultimate load and critical buckling load was 57% and 81.7%, respectively, compared to those values for the non-corroded columns. The ultimate load of the columns with web thickness reduced by 2 mm was 53% lower than that of the non-corroded columns, which indicates that web corrosion most significantly affects the bearing capacity of the columns with localized corrosion. The results predicted using the design specifications of MOHURD were more accurate than those predicted using the design specifications of AISI.

A Study on Corrosion Characteristics of Multilayered WC- $Ti_{1-x}$A $l_{x}$N Coatings Deposited on AISI D2 Steel

  • Ahn, S.H.;Yoo, J.H.;Kim, J.G.;Lee, H.Y.;Han, J.G.
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • $WC-Ti_{1}$ -xA $l_{x}$ N multilayered coatings are performed by their periodically repeated structures of lamellae of WC-Ti/$WC-Ti_{1}$ -xA $l_{x}$ Nmaterials. The $WC-Ti_{1}$ -xA $l_{x}$ N coatings with variable Al content were deposited onto AISI D2 steel by cathodic arc deposition (CAD) method. The electrochemical behavior of multilayered $WC-Ti_{1}$ -xA $l_{x}$ N coatings with different phases (WC- Ti$0.6/Al_{0.4}$ N, $WC-Ti_{0.53}$$Al_{0.47}$N, $WC-Ti_{0.5}$ $Al_{0.5}$ N and $WC-Ti_{ 0.43}$$Al_{0.57}$ N) was investigated in deaerated 3.5% NaCl solution at room temperature. The corrosion behaviors for the multilayered coatings were investigated by electrochemical techniques (potentiodynamic polarization) and surface analyses (X-ray diffraction (XRD), scanning electron microscopy (SEM), and glow discharge optical emission spectroscopy (GDOES)). In the petentiodynamic polarization test, the corrosion current density of $WC-Ti_{0.5}$$Al_{0.5}$N was lower than others.

A study on the fatigue and fracture characteristics of localized nuclear reactor vessel material (국산 원자로용기 재료의 피로 및 파괴특성 연구)

  • Jeong, Sun-Eok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1626-1635
    • /
    • 1997
  • It is important to ensure the reliability of the first localized reactor vessel steel. To satisfy with this purpose, a study on the impact/hardness, low cycle fatigue(LCF), crack growth rate(da/dN) and fracture toughness( ) of base material(BM) and weld metal(WM) were performed under room temperature air and corrosion conditions. A summary of the results is as folows : (1) Charpy impact absorbed energy of BM was the highest value, heat affected zoon(HAZ) and the lowest, WM. The hardness of BM was similar to HAZ. (2) Coefficients of Manson equation using the monotonic tensile test data were obtained for the present material. (3) The effects of stress ratio and ambient (120.deg. C and NaCl) condition on da/dN were investigated, da/dN with NaCl condition expressed the highest value. (4) The results of Charpy V-notch impact test had good correlation with $K_{IC}$ characteristics and the lowest curve of $K_{IC}$ for BM was derived, more researches about WM and HAZ are required hereafter.

A Study on the Degradation of Polymer-Coated Stesl in 0.5M NaCl Solution (0.5M NaCl 용액내에서 일어나는 고분자재료로 피복된 강의 퇴화에 관한 연구)

  • Byeon, Su-Il;Jeong, In-Jo;Mun, Seong-Mo;An, Sang-Ho
    • Korean Journal of Materials Research
    • /
    • v.6 no.10
    • /
    • pp.1025-1033
    • /
    • 1996
  • 본 연구에서는 0.5M NaCI 용액내에서 일어나는 고분자재료로 피복된 강의 퇴화현상을 광학현미경 관찰 및 A.C. impedance spectroscopy를 이용하여 연구하였다. 강의 부식은 고분자재료로 피복된 강의 경우 국부부식(localized corrosion)의 형태로 나타난 반면, 피복되지 않은 강의 경우에는 전면부식(uniform corrosion)의 형태로 진행되었다. 고분자재료로 피복된 강의 부식이 국부적으로 진행되는 것은 피복층내에 존재하는 기공이나 크랙과 같은 결함 등에서 부식이 선택적으로 일어나기 때문으로 사료된다. 피복층의 박리(delamination) 현상은 고분자재료로 피복된 강/구리 갈바닉쌍(galvanic couple)의 경우 구리표면 위의 피복층에서만 관찰되었다. 이는 캐소드(cathode)로 작용하는 구리의표면에서 산소의 환원반응에 의해서 형성된 수산화이온(OH-)이 피복층의 박리를 조장하고 있음을 보여준다. 또한, 고분자재료 피복층의 파손 현상은 고분자재료/강의계면에서 석출된 부식생성물에 의해서 크게 조장되고 있음을 알 수 있다.

  • PDF

Electrochemical Hydrogen Permeation Behaviors of Pre-Strained Fe-Mn-C TWIP Steel With or Without Zn Coating (소성인장변형 몇 아연도금된 Fe-Mn-C계 TWIP 강의 전기화학적 수소투과거동)

  • Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.297-303
    • /
    • 2023
  • This study aimed to evaluate hydrogen permeation behaviors of pre-strained twinning-induced plasticity steel with or without Zn coating using electrochemical permeation technique. In contrast to un-strained and 30% strained samples, permeation current density was measured in the 60% strained sample. Tensile pre-straining at 60% involved microstructural modifications, including a high level of dislocation density and stacking fault with a semi-coherent twin boundary, which might provide a high diffusion path for hydrogen atoms. However, reproducibility of measurements of hydrogen permeation current was low due to non-uniform deformation and localized stress concentration. On the other hand, the permeation current was not measured in pre-strained TWIP steel with Zn coating. Instead, numerous blisters with some cracks were observed on the surface of the coating layer. In locally damaged Zn coating under tensile straining, hydrogen atoms could relatively easily permeate through the coating layer. However, they were trapped at the interface between the coating layer and the substrate, which might delay hydrogen penetration into the steel substrate.

In-Situ SEM Observation and DIC Strain Analysis for Deformation and Cracking of Hot-Dip ZnMgAl Alloy Coating

  • Naoki Takata;Hiroki Yokoi;Dasom Kim;Asuka Suzuki;Makoto Kobashi
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.113-120
    • /
    • 2024
  • An attempt was made to apply digital image correlation (DIC) strain analysis to in-situ scanning electron microscopy (SEM) observations of bending deformation to quantify local strain distribution inside a ZnMgAl-alloy coating in deformation. Interstitial-free steel sheets were hot-dipped in a Zn-3Mg-6Al (mass%) alloy melt at 400 ℃ for 2 s. The specimens were deformed using a miniature-sized 4-point bending test machine inside the SEM chamber. The observed in situ SEM images were used for DIC strain analysis. The hot-dip ZnMgAl-alloy coating exhibited a solidification microstructure composed of a three-phase eutectic of fine Al (fcc), Zn (hcp), and Zn2Mg phases surrounding the primary solidified Al phases. The relatively coarsened Zn2Mg phases were locally observed inside the ZnMgAl-alloy coating. The DIC strain analysis revealed that the strain was localized in the primary solidified Al phases and fine eutectic microstructure around the Zn2Mg phase. The results indicated high deformability of the multi-phase microstructure of the ZnMgAl-alloy coating.

Applications of Micro-Droplet Cell to Study of Localized Corrosion Resistance of Stainless Steels (스테인리스강의 국부부식 저항성 연구에 미세방울셀의 응용)

  • Kim Sung-Yu;Kim Hee-San
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.2
    • /
    • pp.70-76
    • /
    • 2006
  • Micro-droplet cell with free droplet as a micro-electrochemical technique has been limited to apply to electrochemical systems with high wetting properties such as an acidic solution and low grade stainless steels(Type 316L). By loading negative pressure to a droplet, control of droplet size, and use of hydrophobic gasket, the cell is modified to be allowed to use for electrochemical systems with high wetting properties. For giving the reliability of new cell, studies on local corrosion were conducted for three different systems-an acidic chloride solution and high chromium ferritic stainless steel, the other acidic chloride solution and type 316, and a neutral chloride solution and type 316. stainless steel. Firstly, the modified micro-droplet cell allows the anodic polarization curves in an acidic chloride solution to show the fact that the local corrosion of high chromium stainless steel near the $\alpha/\sigma$ interface is due to the Cr depleted zone. Secondly, the local anodic polarization test of type 316 L in the other acidic chloride solution can be successfully conducted in the cell. Furthermore, the local polarization curves help elucidating the corrosion of type 316 with $\delta-ferrite$ phase. Finally, the polarization curves of type 316 L in a neutral chloride solution indicates that the factor affecting the pitting corrosion resistance was inclusions rather than $\delta-ferrite$.

AFM based Surface Verifications of Pulse Electrochemical Polishing for Various Frequency Conditions (주파수 변화에 따른 AFM 기반의 펄스 전기화학 폴리싱 표면특성 분석)

  • Kim, Young-Bin;Kim, Jong-Tye;Ahn, Dong-Gyu;Park, Jong-Rak;Jeong, Sang-Hwa;Park, Jeong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.246-251
    • /
    • 2012
  • Pulse electrochemical polishing process has been used to improve mechanical properties such as surface roughness and corrosion resistance on conductive metallic materials. In addition, pulse electrochemical polishing process with various frequency may produce a lustrous, smoother, deburred and cleaned surface on workpiece. The aim of this paper is to study surface characteristics of pulse electrochemical polishing for various frequency conditions using AFM to verify localized surface variation in nanometer scale.

High Durability of Stack for Automobile (차량용 스택 고출력 내구성능)

  • Kim, Young-Min;Lee, Jong-Hyun;Yoon, Jong-Jin;Cho, Jang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.557-560
    • /
    • 2007
  • The durability of 80 kW class stack module was tested in hydrogen recirculation and non-recirculation systems with the condition of 300Amps (constant current mode) and hydrogen pulse purging (10 seconds close/0.8 seconds open). A localized membrane failure in the interfacial area between membrane and sub-gasket, carbon corrosion in cathode electrode, and Pt dissolution/extraction have been found through the post mortem analysis such as CV, Impedance, SEM, and so on. The main reason of these mechanisms will be discussed in this study.

  • PDF

Researches on the Enhancement of Plasticity of Bulk Metallic Glass Alloys

  • Kim, Byoung Jin;Kim, Won Tae
    • Applied Microscopy
    • /
    • v.45 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • Bulk metallic glass (BMG) shows higth strength, high elastic limit, corrosion resistance and good wear resistance and soft magnetic properties and has been considering as a candidate for new structural materials. But they show limited macroscopic plasticity and lack of tensile ductility due to highly localized shear deformation, which should be solved for real structural application. In this paper researches on the enhancement of plasticity of BMG were reviewed briefly. Introducing heterogeneous structure in glass is effective to induce more shear transformation zones (STZs) active for multiple shear band initiation and also to block the propagating shear band. Several methods such as BMG alloy design for high Poisson's ratio, addition of alloying element having positive heat of mixing, pre-straining BMG and variety of BMG composites have been developed for homogenous distribution of locally weak region, where local strain can be initiated. Therefore enhancement of plasticity of BMG is normally accompanied with some penalty of strength loss.