• 제목/요약/키워드: Local ventilation

검색결과 209건 처리시간 0.029초

전산실의 환기성능 최적화를 위한 연구 (A Study for Optimization the Ventilation Performance of the Computer Room)

  • 권용일
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.57-62
    • /
    • 2015
  • The objective of the present study is to identify the ventilation problems and to suggest the optimal ventilation system to save energy and to improve IAQ in the computer rooms, which annually performs the cooling operation by the server with the highly thermal load. Numerical results on the temperature and local mean age are presented along with some of the discharge velocities. Results show many interesting aspects of airflow patterns affecting the ventilation performances, according to the discharge velocity of the supply diffuser installed in the bottom surfaces between the servers. As the results, 2.5 m/s of the optimal discharge velocity is needed in order to improve the ventilation performance.

추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험 (Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space)

  • 한화택;서세영;김명호;김영일
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

오염발생원의 위치인식에 의한 환기장치 제어방안 (Ventilation System Control by Location-Aware of Pollution Source)

  • 한화택;한정일;권용일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.405-410
    • /
    • 2006
  • This paper presents a control algorithm of supply and exhaust diffusers by recognizing a contaminant source location. CFD analysis has been conducted to calculate steady state airflow and concentration distributions in a model room, which has two supply and two exhaust openings on the ceiling. Calculations have been performed for five cases out of nine different ventilation modes by combining on/off control of the supply and exhaust openings. Local mean residual life times are obtained and compared at 9 internal points for each ventilation case. Depending on the contaminant source location, the ventilation system is operated at an optimum ventilation mode, which can results in maximum exhaust performance.

  • PDF

스프레드시트 모델을 이용한 비표준 공기상태에서의 국소환기시스템의 설계 (Design of a Local Ventilation System in the Non-Standard Air Condition using the Spreadsheet Model)

  • 조석호
    • 한국환경과학회지
    • /
    • 제6권6호
    • /
    • pp.645-658
    • /
    • 1997
  • A study on ventilation design using the spreadsheet model is carried out to propose means of available design. A sample of complex ventilation system In the non-standard condition Is used to illustrate thins spreadsheet model. In developing the spreadsheet model, this study has attempted to it general by using computional equations and design parameters that can be readily applied to any spreadsheet software. Also, most design data is contained in the spreadsheet template. This template provides the same design information as the ACGIH worksheet, and operates Quickly and emclenuy, and is fiexible enough to use under different conditions. This spreadsheet model allows the ventilation engineer to design quickly and accurately the ventilation system, without spending too much effort In the design process. By storing on computer and diskette, the design data computed finally can be used as a permanent record of specific ventilation system, and because of finally to be able to design over and over again while making only slight changes to the Input data, the spreadsheet model is used availably to accomplish the design optimazation by redesign and troubleshooting by review from field measurements. Also, the spreadsheet model is available for designing ventilation system under different condition or evaluating existing system or design drawing, because changes In the layout or formulae can be readily made to fit the needs of the designer.

  • PDF

실내 기류패턴에 따른 급기효율과 배기효율의 분포 (Distributions of Local Supply and Exhaust Effectiveness according to the Room Airflow Patterns)

  • 한화택;최선호;장경진
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.853-859
    • /
    • 2001
  • A pulsed tracer gas technique is applied to measure distributions of local mean age and residual life time of air in a half-scale experimental chamber. The room airflow patterns are flow-visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is either at bottom-left(Case 1), bottom-right(Case 2), or top-left(Case 3) location. Results show that the distribution of LMA and LMR are different from each other, but both of them are closely related to the airflow pattern in the space. Results on overall room ventilation effectiveness are provided depending upon ventilation airflow rates for three different supply-exhaust configurations.

  • PDF

아연도금 부스 환기시스템 개선에 관한 수치해석 (Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.

대구지역의 국지적 대기순환풍의 환기경로에 관한 수치모의 실험 (Numerical Simulation Experiment on the Wind Ventilation Lane of the Local Circulation Winds in Daegu)

  • 구현숙;김해동;강성대
    • 한국환경과학회지
    • /
    • 제13권4호
    • /
    • pp.367-376
    • /
    • 2004
  • In urban area, thermal pollution associated with heat island phenomena is generally regarded to make urban life uncomfortable. To overcome this urban thermal pollution problem, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane, is widely practiced in many countries. In this study, the prevailing wind ventilation lane of a local winds in Daegu during the warm climate season was investigated by using surface wind data and RAMS(Reasonal Atmospheric Model System) simulation. The domain of interest is the vicinity of Daegu metropolitan city(about 900 $km^{2})$ and its horizontal scale is about 30km. The simulations were conducted under the synoptic condition of late spring with the weak gradient wind and mostly clear sky. From the numerical simulations, the following two major conclusions were obtained: (1)The major wind passages of the local circulation wind generated by radiative cooling over the mountains(Mt. Palgong and Mt. Ap) are found. The winds blow down along the valley axis over the eastern part of the Daegu area as a gravity flow during nighttime. (2)After that time, the winds blow toward the western part of Daegu through the city center. As the result, the higher temperature region appears over the western part of Daegu metropolitan area.

Dry room내 수분환기에 대한 수치적 연구 (Numerical Analysis of Moisture Ventilation in the Dry Room)

  • 이관수;임광옥;정영식
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.908-916
    • /
    • 2000
  • In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standard $k-\varepsilon$ turbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency (SVE1) and the 2nd scale of ventilation efficiency (SVE2), respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications.

  • PDF

실험을 통한 환기시스템의 국소적 환기효율 분석 (Analysis of the Local Air-Change Effectiveness by Field Measurement)

  • 최연희;송두삼
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.63-67
    • /
    • 2017
  • The purpose of this study is to analyze the Age of Air and the Local Air-change Effectiveness of by field measurement. The indexes of Age of Air and Local Air-change Effectiveness are used to analyze the local ventilation effectiveness of multiple locations and are mainly evaluated using the computational fluid dynamics (CFD) method. In this study, measurement of the Local Air-change Effectiveness was based on ASHRAE 129. The performance of Local Air-change Effectiveness and the dependence of the outlet location on Local Air-change Effectiveness were analyzed. The results showed that a greater air-change rate (ACH) may not guarantee better local ventilation effectiveness.

코팅 룸 배기시스템 수치해석 및 성능개선에 대한 연구 (A Study on Numerical Analysis and Performance Improvement of Ventilation Systems in Coating Room)

  • 이기연;김국원
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2086-2091
    • /
    • 2013
  • 산업환기의 근본 목적은 유해물질로부터 작업자의 건강을 지키는 것으로, 제품생산과정에서 발생하는 유해물질 등을 빠른 시간에 외부로 배출하여 공기의 질을 높이고자 한다. 최근 산업환기에 대한 인식이 생산중심에서 인간중심으로 변하면서 이에 대한 중요성이 증가하고 있다. 본 연구에서는 아연말 코팅 룸에서 발생하는 악취제거를 목적으로 코팅 룸 내부의 공기유동에 대한 전산 시뮬레이션을 수행하였다. 3차원 CAD 프로그램인 SolidWorks를 이용하여 코팅 룸 전체와 배기시스템을 모델링하였으며 Flow Simulation 프로그램을 이용하여 오염물 발생 부위 중심으로 배기성능을 분석하였다. 또한 국소배기 장치를 이용하여 코팅 룸 내부 공기의 흐름 방향과 공기의 유속을 개선하였다.