• Title/Summary/Keyword: Local flow analysis

Search Result 620, Processing Time 0.023 seconds

Comparative Analysis of Wind Flows in Wind Corridor Based on Spatial and Geomorphological Characteristics to Improve Urban Thermal Environments (도시 열환경개선을 위한 공간지형적 특성에 따른 바람길 유동 비교 분석)

  • SEO, Bo-Yong;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.75-88
    • /
    • 2017
  • This study analyzed wind flows based on spatial and geomorphological characteristics of Daegu Metropolitan City. A three-stage analysis was performed, starting with a comparison of meteorological relationships between local wind direction (synoptic wind) and local wind flow. In the second stage the study area was subdivided into districts and suburban districts to analyze the relative change of local wind flow. In stage three, the formation of wind corridor for local wind flow, wind flow for the entire urban space, and spatial relationships between flows were verified comparatively using KLAM_21. Three results are notable, the first of which is a low correlation between synoptic wind of a region, and local wind, flow in terms of meteorology. Secondly, observations of local wind flow at five downtown districts and two suburban districts showed that there were diverse wind directions at each measurement point. This indicates that the spatial and geomorphological characteristics of areas neighboring the measurement points could affect the local wind flow. Thirdly, verifying the results analyzed using KLAM_21, compared to Atomatic Weather System(AWS) measurement data, confirmed the reliability of the numerical modelling analysis. It was determined that local wind flow in a city performs a spatial function and role in ameliorating the urban heat island phenomena. This indicates that, when an urban planning project is designed, the urban heat island phenomena could be ameliorated effectively and sustainably if local wind flow caused by immediate spatial and geomorphological characteristics is confirmed systematically and techniques are intentionally applied to connect the flows spatially within areas where urban heat islands occur.

ESTIMATION OF LOCAL LIQUID FILM THICKNESS IN TWO-PHASE ANNULAR FLOW

  • Lee, Bo-An;Yun, Byong-Jo;Kim, Kyung-Youn;Kim, Sin
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.71-78
    • /
    • 2012
  • In many semi-empirical analyses of flow boiling heat transfer, an annular flow is often assumed as a model flow and the local liquid film thickness is a key parameter in the analysis. This work considers a simple electrical conductance technique to estimate the local liquid film thickness in two-phase annular flows. In this approach, many electrodes are mounted flush with the inner wall of the pipe. Voltage differences between two neighboring electrodes for concentric annular flows with various liquid film thicknesses are obtained before the main experiments and logged in a look-up table. For an actual application in the annual flow, voltage differences of neighboring electrodes are measured and then corresponding local film thicknesses are determined by the interpolation of the look-up table. Even though the proposed technique is quite simple and straightforward, the numerical and static phantom experiments support its usefulness.

A Study on the Measurement of Local Void Fraction (수직사각 유로내에서의 국부적 기포계수 측정에 관한 연구)

  • B.J. Yun;Kim, K.H.;Park, G.C.;C.H. Chung
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.168-177
    • /
    • 1992
  • The importance of the study of two phase flow phenomena has increased for both fuel performance and safety analysis of nuclear power plants. In the analysis of two phase flow system, an accurate prediction of local void fractions is very important. In this study, a vertical rectangular subchannel having 4 electrically heated rods is constructed for the measurement of local void fraction under two phase flow. The measurement has been conducted by electrical conductivity probes and signal processing circuit which are known to be adequate to measuring local void fraction. Also experiments are performed with varying the inlet flow rate to search for radial void fraction profile accordingly to the different flow rate even with the same averaged void fraction. From the result of experiments, the validity of electrical conductivity probe and electrical circuit is confirmed.

  • PDF

A Dual-Scale Analysis of Macroscopic Resin Flow in Vacuum Assisted Resin Transfer Molding Process (VARTM공정에서의 거시적 수지 유동의 Dual-Scale 분석)

  • 박윤희;강문구;이우일
    • Composites Research
    • /
    • v.15 no.6
    • /
    • pp.1-7
    • /
    • 2002
  • In VARTM process where a sacrificial medium is used to facilitate the resin flow, the velocity of resin varies drastically between the sacrificial medium and the fiber preform. Although the thickness-to-length ratio of a VARTM product is usually small, a 3-D analysis is prerequisite to analyze the lead-lag flow in the two different media. The problem associated with the full 3-D analysis is the CPU time. A full 3-D numerical mesh comprising large number of nodes requires an impractical CPU time on average computer platforms. In this study, a dual-scale analysis technique was developed. The flow analysis for the entire calculation domain was conducted in 2.5-D, and the 3-D analysis was performed for a small area of special concern. In some numerical examples, the local 3-D analysis could discover an eccentric flow pattern as well as the lead-lag flow that will inevitably be neglected in 2.5-D simulations. The global-local analysis technique practiced in this study can be used to analyze the intricate flow of resin through non-uniform media in affordable CPU times.

Finite Element Analysis and Local a Posteriori Error Estimates for Problems of Flow through Porous Media (다공매체를 통과하는 유동문제의 유한요소해석과 부분해석후 오차계산)

  • Lee, Choon-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.850-858
    • /
    • 1997
  • A new a posteriori error estimator is introduced and applied to variational inequalities occurring in problems of flow through porous media. In order to construct element-wise a posteriori error estimates the global error is localized by a special mixed formulation in which continuity conditions at interfaces are treated as constraints. This approach leads to error indicators which provide rigorous upper bounds of the element errors. A discussion of a compatibility condition for the well-posedness of the local error analysis problem is given. Two numerical examples are solved to check the compatibility of the local problems and convergence of the effectivity index both in a local and a global sense with respect to local refinements.

Optimization Condition for Injection Molding of TV Speaker Grille Using CAE (CAE를 이용한 TV Speaker Grille 사출 성형의 최적화)

  • 김범호;장우진;김정훈;정지원;박영훈
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.855-865
    • /
    • 2001
  • The optimization condition of injection molding for a commercial product of TV speaker grille of A Company was induced using a CAE software of Moldflow. The flow and packing phase analysis was performed by using flow balance, runner balance, and the intermediate one by using the above two balances, which were used for controlling the amount of packing resins into the cavity, Later, the analysis performed by using the measured viscosity (local database) at various shear rates and the results were compared with the computer simulation using the standard database. Flow balance induced minimized weld line resulted in a better appearance and physical properties of the were line, but exhibited a disadvantage of large deformation and gas formation due to over-packing of the molten resin in the center of the speaker grille. Runner balance improved the disadvantage of the flow balance by controlling the amount of molten resin injected from the gate, however resulted reduced mechanical properties and poor appearance of the weld line. However, the modified method induced from the flow and runner balance improved the disadvantages by changing the runner size. In addition, the analyses based on the local database and the standard database were compared. Although the measured viscosity was slightly higher and the temperature distribution was broader than the standard database, no distinct difference was obtained from the analysis using the two different databases.

  • PDF

Investigation of Local Convective Heat Transfer around a Circular Tube in Cross Flow of Air (원관 주위로 공기의 국소 대류 열전달에 대한 연구)

  • 이억수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.546-555
    • /
    • 2004
  • With circular tube heated directly or indirectly placed in a cross flow, heat flows circumferentially by conduction due to the asymmetric nature of the fluid flow around the perimeter of the circular tube. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases. The effects of circumferential wall heat conduction on local convective heat transfer is investigated. The wall heat conduction parameter which can be deduced from the governing energy equation should be used to express the effect of circumferential heat conduction. Two-dimensional temperature distribution is presented through the numerical analysis. The comparison of one-dimensional and two-dimensional solutions is demonstrated on graph of local Nusselt numbers.

Analysis of Flow Field in Cavity Using Finite Analytic Method (F.A.M.을 이용한 공동 내부의 유동해석)

  • 박명규;정정환;김동진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.46-53
    • /
    • 1991
  • In the present study, Navier-Stokes equation is numerically solved by use of a Finite analytic method to obtain the 2-dimensional flow field in the square cavity. The basic idea of F.A.M. is the incorporation of local analytic solutions in the numerical solution of linear or non-linear partial differential equations. In the F.A.M., the total problem is subdivided into a number of all elements. The local analytic solution is obtained for the small element in which the governing equation, if non-linear, to be linearized. The local analytic solutions are then expressed in algebraic form and are overlapped to cover the entire region of the problem. The assembly of these local analytic solutions, which still preserve the overall nonlinearity of the governing equations, results in a system of linear algebraic equations. The system of algebraic equations is then solved to provide the numerical solutions of the total problem. The computed flow field shows the same characteristics to physical concept of flow phenomena.

  • PDF

A Study on Numerical Analysis and Wall Thinning Effect in Accordance with the Eddy Current of MFIV Lower Body (주급수격리밸브 하부몸체의 와류현상에 따른 감육영향 및 수치해석 연구)

  • Hwang Kyeong-Mo;Jin Tae-Eun;Kim Kyung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.707-714
    • /
    • 2006
  • A numerical analysis study has performed in terms of fluid dynamics to identify the wall thinning generated in the main feedwater isolation valve body of a nuclear power plant. To review the relations between flow characteristics and the wall thinning induced by flow accelerated corrosion (FAC), numerical analysis using FLUENT code and ultrasonic tests (UT) were performed. The local velocities according to the analysis results were compared with the distribution of the measured wall thickness by ultrasonic tests. The comparison results show that the local velocity in the x-direction had no correlation with the wall thinning but the local velocity in the y-direction and turbulence intensity had a great influence on that. These results provide a good match to those of the previous studies - locations colliding vertically against components undergo severe wall thinning. These results may be utilized to the design modification and the wall thinning management for main feedwater isolation valves for preventing the wall thinning degradation.

The Effects of Local Anesthetic Agent and Epinephrine on Blood Flow of Femoral Artery in Rabbit (가토에서 국소 마취제와 Epinephrine이 대퇴동맥이 혈류에 미치는 영향)

  • Oh, Soo-Won;Koo, Gil-Hoi;Lee, Choon-Hi
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.46-56
    • /
    • 1996
  • Many surgeons and anesthesiologists prefer using vasoconstrictor mixed with local anesthetic agent to reduce the incidence of side effects and prolong the duration of analgesia because most local anesthetic agents, except cocaine, were believed to possess vasodilating effect. However, some investigators recently reported vasoconstricting effect of local anesthetic agents. There is still controversy on the vasoactive effect of local anesthetic agents. So this study is aimed to clarify the vasoactive effect of local anesthetics in the animal model resembling clinical settings. Rabbits were anesthesized with ketamine and haloghane, and respirations were controlled with Harvard animal ventilator. Lidocaine (0.5%, 1.0%, 1.5%) and bupivacaine (0.125%, 0.25% and 0.5%) with or without 1:100,000 epinephrine were subdermaly injected on the femoral bupivacaine of the femoral artery were measured with Doppler flow meter in vivo. The mean arterial pressure, pulse rate, arterial blood gases, pH and level of serum electrolytes were measured at every 2 minute interval for 30 minutes. Results were as follows: 1) There was no significant vasoconstriction with 0.5% lidocaine and 0.125% bupivacaine. 2) Statistically significant (p<0.05) vasodilations were observed with lidocaine (1.0~2.0%) and bupivacaine (0.25~0.5%). 3) There were no changes on the duration of vasodilation induced by local anesthetic agents of various concentrations. 4) Onset of vasodilation induced by local anesthetic agents of high concentration were faster than that of lower concentrations. 5) In the mixed injection group of epinephrine and local anesthetic agent, the vasoconstriction induced by epinephrine was completely reversed by local anesthetics, approximately 5 minutes later. In conclusion, local anesthetic agents at dose exceeding 1.0% lidocaine and 0.25% bupivacaine increase local blood flow significantly in animal study in vivo which is applicable in human clinical settings. The increase blood flow may be due to dilatation of blood vessel. Further study on the analysis of association between amount of absorbed local anesthetics in blood vessels and dilatation of blood vessels is needed.

  • PDF