• Title/Summary/Keyword: Local fire

Search Result 352, Processing Time 0.03 seconds

Drag Reduction of Pipe Wall For Fluid Flow due to Injected Polymer Solution - II. Local Drag Reduction in Turbulent Flow- (고분자용액에 의한 유체수송관벽의 저항감소 -II. 난류흐름에서 국소저항감소-)

  • 추낙준;유경옥
    • Fire Science and Engineering
    • /
    • v.5 no.2
    • /
    • pp.11-20
    • /
    • 1991
  • Dilute polymer solutions were injected into turbulent pipe flow of a Newtonian fluid. The local drag reduction for injection of polymer solution at the pipe wall was larger than that at centerline. From the above result we may conclude that the polymer additives were found to influence the flow in the neighborhood of the wall. The effects of the injection apparatus on the local drag reduction are small compared to the drag-reducing effects. The extent of drag reduction increased with polymer concentration and injection flow rate, and the maximum drag reduction obtained were 47% for Polyox Coagulant and 35% for Separan AP-273. In respect to polymer degradation, the polyacrylamide showed better shear stability than the polyethyleneoxide and thus the former expected to have a sharper molecular weight distribution.

  • PDF

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

An Quantitative Analysis of Severity Classification and Burn Severity At the targe-fire Areas Using NBR Index of Landsat Imagery (Landsat NBR지수를 이용한 대형산불 피해지 구분 및 피해강도의 정량적 분석)

  • Won, Myoung-Soo;Koo, Kyo-Sang;Lee, Myung-Bo
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.231-237
    • /
    • 2007
  • To monitor process of vegetation rehabilitation at the damaged area after large-fire is required a lot of manpowers and budgets. However the analysis of vegetation recovery using satellite imagery can be obtaining rapid and objective result remotely in the large damaged area. Space and airbone sensors have been used to map area burned, assess characteristics of active fires, and characterize post-fire ecological effects. Burn severity incorporates both short- and long-term post-fire effects on the local and regional environment. Burn severity is defined by the degree to which an ecosystem has changed owing to the fire. To classify fire damaged area and analyze burn severity of Samcheok fire area occurred in 2000, Cheongyang fire 2002, and Yangyang fire 2005 was utilized Landsat TM and ETM+ imagery. Therefore the objective of the present paper is to quantitatively classify fire damaged area and analyze burn severity using normalized burn index(NBR) of pre- and post-fire's Landsat satellite imagery.

  • PDF

A Study on Improvement of Discharge Pressure Measurement of Indoor Fire Hydrant System (옥내소화전설비의 방수압 측정 개선에 관한 연구)

  • Min, Se-Hong;Jeong, Sang-Ho
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.67-72
    • /
    • 2012
  • Indoor fire hydrant facilities and sprinkler system applied to the initial fire suppression for buildings' interior fire are pivotal roles in extinguishing the fire in the early stage. The roof shapes of recent buildings combined with distinctive local culture and design are being constructed. Distinctive roof forms, i.e. gable roof buildings are planned and built, View point planning with the roof gardens also restricts measurement of the discharge pressure on the indoor fire hydrant, It is too narrow to gauge the water discharge pressure with deploying up to 5 water hoses. To resolve these problems improvement for the efficient management of indoor fire hydrant system and the effective early stage flame extinguishment is suggested.

Analysis of the Situation of the Volunteer Fire Brigade in Japan (일본 의용소방대 실태의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.44-50
    • /
    • 2011
  • Japan has a very advanced volunteer fire brigade system as an interdependent organization by local residents due to frequent natural disasters. Japan has fostered and developed the volunteer fire brigade in the national level to response rapidly and appropriately to earthquake or natural disasters even in the urban area that has sufficient fire stations and fire officers. This study analyzes the situation of operating the volunteer fire brigade in Japan in detail and compares the result with Korean situation. Finally, this study suggests policies which can be introduced to activate the volunteer fire brigade in Korea.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

'Probable Errors' as an EIA Method to Define Project Impact Area - Focusing on the Preparation of 'Howitzer' Fire Training Site - (공산오차를 적용한 환경영향평가 대상지역 설정 기준에 관한 연구 - 곡사화기 사격장 조성사업을 중심으로 -)

  • Kang, Jaegu;Choi, Joon-Gyu;Cho, Kong-Jang;Joo, Yong-Joon;Han, Myung-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.495-502
    • /
    • 2007
  • In Korea, military authorities have neglected to consider impacts of military projects on local communities and natural environment. Moreover, local communities have had difficulties in dealing with the Ministry of National Defense (MND), which was stubborn enough not to implement environmental assessment on their projects. In this situation, recent case, "EIA of Baekgol Division's Howitzer Fire Training Site" in the Supreme Court-in which judges upheld the Higher Court's decision that the division violated the Environmental Impact Assessment law by ignoring to implement EIA-reveals that military projects can no longer forgo environmental assessment. The decision has serious ramifications on the future of Environmental Impact Assessment in military-led projects. This paper examines the proper scope of EIA in military-led projects and, more specifically, fire training site and searches for how to improve it through 'probable error,' a military training method that is applied to real 'howitzer' fire training. Probable error of the artillery field manual is nothing more than an error that exceeded as often as it is not exceeded and its scientific method was demonstrated through real fire tests in the US. Army. If it is applied to improve assessment methods about the proper scope of EIA in military 'howitzer' fire training site, 'probable error' will improve effect prediction, mitigation and reliability.

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.